Analytical and Clinical Evaluation of the AltoStar Adenovirus PCR Kit 1.5 and the AltoStar Automation System AM16 for Adenovirus Detection in Plasma and Stool Samples
Krupa Jani , Taheefa Stephen , Cindy Lee , Arianna Pinto , Tracy McMillen , June L. Chan , N. Esther Babady
{"title":"Analytical and Clinical Evaluation of the AltoStar Adenovirus PCR Kit 1.5 and the AltoStar Automation System AM16 for Adenovirus Detection in Plasma and Stool Samples","authors":"Krupa Jani , Taheefa Stephen , Cindy Lee , Arianna Pinto , Tracy McMillen , June L. Chan , N. Esther Babady","doi":"10.1016/j.jmoldx.2025.08.003","DOIUrl":null,"url":null,"abstract":"<div><div>Human adenoviruses (HAdVs) can result in significant morbidity and mortality in immunocompromised patients. The AltoStar Adenovirus PCR Kit 1.5 (AltoStar HAdV PCR) is a real-time PCR test for the detection and quantification of HAdV DNA. In this study, the performance of the AltoStar HAdV PCR was evaluated compared with a laboratory-developed HAdV PCR based on MultiCode HAdV reagents (MultiCode HAdV PCR) using plasma and stool specimens. Performance of the AltoStar HAdV PCR was established by determining the linearity, lower limit of detection, precision, specificity, accuracy, and inclusivity of the assay. Accuracy was determined by testing plasma and stool clinical samples previously tested by the MultiCode HAdV PCR and inclusivity evaluated by using several HAdV genotypes. A time-and-motion study was performed to compare the workflows of both PCRs. The limit of detection was <200 copies/mL for both sample types. Overall agreement with the MultiCode HAdV PCR was 91% for plasma samples and 85.5% for stool samples. Quantitative agreement between the two tests was moderate. Specificity and precision in both sample types were high. All major HAdV species tested were detected. Hands-on-time was significantly less for the semi-automated AltoStar HAdV PCR. The AltoStar HAdV PCR showed great performance for the detection and/or quantitation of HAdV in clinical samples.</div></div>","PeriodicalId":50128,"journal":{"name":"Journal of Molecular Diagnostics","volume":"27 11","pages":"Pages 1115-1122"},"PeriodicalIF":3.9000,"publicationDate":"2025-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Molecular Diagnostics","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1525157825001990","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/9/1 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"PATHOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Human adenoviruses (HAdVs) can result in significant morbidity and mortality in immunocompromised patients. The AltoStar Adenovirus PCR Kit 1.5 (AltoStar HAdV PCR) is a real-time PCR test for the detection and quantification of HAdV DNA. In this study, the performance of the AltoStar HAdV PCR was evaluated compared with a laboratory-developed HAdV PCR based on MultiCode HAdV reagents (MultiCode HAdV PCR) using plasma and stool specimens. Performance of the AltoStar HAdV PCR was established by determining the linearity, lower limit of detection, precision, specificity, accuracy, and inclusivity of the assay. Accuracy was determined by testing plasma and stool clinical samples previously tested by the MultiCode HAdV PCR and inclusivity evaluated by using several HAdV genotypes. A time-and-motion study was performed to compare the workflows of both PCRs. The limit of detection was <200 copies/mL for both sample types. Overall agreement with the MultiCode HAdV PCR was 91% for plasma samples and 85.5% for stool samples. Quantitative agreement between the two tests was moderate. Specificity and precision in both sample types were high. All major HAdV species tested were detected. Hands-on-time was significantly less for the semi-automated AltoStar HAdV PCR. The AltoStar HAdV PCR showed great performance for the detection and/or quantitation of HAdV in clinical samples.
期刊介绍:
The Journal of Molecular Diagnostics, the official publication of the Association for Molecular Pathology (AMP), co-owned by the American Society for Investigative Pathology (ASIP), seeks to publish high quality original papers on scientific advances in the translation and validation of molecular discoveries in medicine into the clinical diagnostic setting, and the description and application of technological advances in the field of molecular diagnostic medicine. The editors welcome for review articles that contain: novel discoveries or clinicopathologic correlations including studies in oncology, infectious diseases, inherited diseases, predisposition to disease, clinical informatics, or the description of polymorphisms linked to disease states or normal variations; the application of diagnostic methodologies in clinical trials; or the development of new or improved molecular methods which may be applied to diagnosis or monitoring of disease or disease predisposition.