Nana Xu, Jiabi Zhang, Jialin Luo, Li Wang, Yong Chen, Lijun Zhou, Bihua Chen, Lan Luo, Xiaolu Liu, Shuju Luo, Yong Wang, Zunwei Luo, Li Ding, Mei Li, Manhong Zhou
{"title":"[The impact of different chest compression frequencies on cardiopulmonary resuscitation outcomes in domestic pigs].","authors":"Nana Xu, Jiabi Zhang, Jialin Luo, Li Wang, Yong Chen, Lijun Zhou, Bihua Chen, Lan Luo, Xiaolu Liu, Shuju Luo, Yong Wang, Zunwei Luo, Li Ding, Mei Li, Manhong Zhou","doi":"10.3760/cma.j.cn121430-20250124-00083","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To compare the effects of different chest compression rates (60-140 times/min) on hemodynamic parameters, return of spontaneous circulation (ROSC), resuscitation success, and survival in a porcine model of cardiac arrest (CA) followed by cardiopulmonary resuscitation (CPR).</p><p><strong>Methods: </strong>Forty healthy male domestic pigs were randomly divided into five groups based on chest compression rate: 60, 80, 100, 120, and 140 times/min (n = 8). All animals underwent standard anesthesia and tracheal intubation. A catheter was inserted via the left femoral artery into the thoracic aorta to monitor aortic pressure (AOP), and another via the right external jugular vein into the right atrium to monitor right atrial pressure (RAP). In each group, animals were implanted with a stimulating electrode via the right external jugular vein to the endocardium, and ventricular fibrillation (VF) was induced by delivering alternating current stimulation, resulting in CA. After a 1-minute, manual chest compressions were performed at the assigned rate with a compression depth of 5 cm. The first defibrillation was delivered after 2 minutes of CPR. No epinephrine or other pharmacologic agents were administered during the entire resuscitation process. From 1 minute before VF induction to 10 minutes after ROSC, dynamic monitoring of AOP, coronary perfusion pressure (CPP), and partial pressure of end-tidal carbon dioxide (P<sub>ET</sub>CO<sub>2</sub>). Cortical ultrastructure was examined 24 hours post-ROSC using transmission electron microscopy.</p><p><strong>Results: </strong>With increasing compression rates, both the total number of defibrillations and cumulative defibrillation energy significantly decreased, reaching their lowest levels in the 120 times/min group. The number of defibrillations decreased from (4.88±0.83) times in the 60 times/min group to (2.25±0.71) times in the 120 compressions/min group, and energy from (975.00±166.90)J to (450.00±141.42)J. However, both parameters increased again in the 140 times/min group [(4.75±1.04)times, (950.00±207.02)J], the differences among the groups were statistically significant (both P < 0.01). As compression frequency increased, P<sub>ET</sub>CO<sub>2</sub>, pre-defibrillation AOP and CPP significantly improved, peaking in the 120 times/min group [compared with the 60 times/min group, P<sub>ET</sub>CO<sub>2</sub> (mmHg, 1 mmHg≈0.133 kPa): 18.69±1.98 vs. 8.67±1.30, AOP (mmHg): 95.13±7.06 vs. 71.00±6.41, CPP (mmHg): 14.88±6.92 vs. 8.57±3.42]. However, in the 140 times/min group, these values declined significantly again [P<sub>ET</sub>CO<sub>2</sub>, AOP, and CPP were (10.59±1.40), (72.38±11.49), and (10.36±4.57) mmHg, respectively], the differences among the groups were statistically significant (all P < 0.01). The number of animals achieving ROSC, successful resuscitation, and 24-hour survival increased with higher compression rates, reaching a peak in the 120 times/min group (compared with the 60 times/min group, ROSC: 7 vs. 2, successful resuscitation: 7 vs. 2, 24-hour survival: 7 vs.1), then decreased again in the 140 times/min group (the animals that ROSC, successfully recovered and survived for 24 hours were 3, 3, and 2, respectively). Transmission electron microscopy revealed that in the 60, 80, and 140 times/min groups, nuclear membranes in cerebral tissue were irregular and incomplete, nucleoli were indistinct, and mitochondria were swollen with reduced cristae and abnormal morphology. In contrast, the 100 times/min and 120 times/min groups exhibited significantly attenuated ultrastructural damage.</p><p><strong>Conclusions: </strong>Among the tested chest compression rates of 60-140 times/min, a chest compressions frequency of 120 times/min is the most favorable hemodynamic profile and outcomes during CPR in a porcine CA model. However, due to the wide spacing between groups, further investigation is needed to determine the optimal compression rate range more precisely.</p>","PeriodicalId":24079,"journal":{"name":"Zhonghua wei zhong bing ji jiu yi xue","volume":"37 5","pages":"472-476"},"PeriodicalIF":0.0000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhonghua wei zhong bing ji jiu yi xue","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3760/cma.j.cn121430-20250124-00083","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: To compare the effects of different chest compression rates (60-140 times/min) on hemodynamic parameters, return of spontaneous circulation (ROSC), resuscitation success, and survival in a porcine model of cardiac arrest (CA) followed by cardiopulmonary resuscitation (CPR).
Methods: Forty healthy male domestic pigs were randomly divided into five groups based on chest compression rate: 60, 80, 100, 120, and 140 times/min (n = 8). All animals underwent standard anesthesia and tracheal intubation. A catheter was inserted via the left femoral artery into the thoracic aorta to monitor aortic pressure (AOP), and another via the right external jugular vein into the right atrium to monitor right atrial pressure (RAP). In each group, animals were implanted with a stimulating electrode via the right external jugular vein to the endocardium, and ventricular fibrillation (VF) was induced by delivering alternating current stimulation, resulting in CA. After a 1-minute, manual chest compressions were performed at the assigned rate with a compression depth of 5 cm. The first defibrillation was delivered after 2 minutes of CPR. No epinephrine or other pharmacologic agents were administered during the entire resuscitation process. From 1 minute before VF induction to 10 minutes after ROSC, dynamic monitoring of AOP, coronary perfusion pressure (CPP), and partial pressure of end-tidal carbon dioxide (PETCO2). Cortical ultrastructure was examined 24 hours post-ROSC using transmission electron microscopy.
Results: With increasing compression rates, both the total number of defibrillations and cumulative defibrillation energy significantly decreased, reaching their lowest levels in the 120 times/min group. The number of defibrillations decreased from (4.88±0.83) times in the 60 times/min group to (2.25±0.71) times in the 120 compressions/min group, and energy from (975.00±166.90)J to (450.00±141.42)J. However, both parameters increased again in the 140 times/min group [(4.75±1.04)times, (950.00±207.02)J], the differences among the groups were statistically significant (both P < 0.01). As compression frequency increased, PETCO2, pre-defibrillation AOP and CPP significantly improved, peaking in the 120 times/min group [compared with the 60 times/min group, PETCO2 (mmHg, 1 mmHg≈0.133 kPa): 18.69±1.98 vs. 8.67±1.30, AOP (mmHg): 95.13±7.06 vs. 71.00±6.41, CPP (mmHg): 14.88±6.92 vs. 8.57±3.42]. However, in the 140 times/min group, these values declined significantly again [PETCO2, AOP, and CPP were (10.59±1.40), (72.38±11.49), and (10.36±4.57) mmHg, respectively], the differences among the groups were statistically significant (all P < 0.01). The number of animals achieving ROSC, successful resuscitation, and 24-hour survival increased with higher compression rates, reaching a peak in the 120 times/min group (compared with the 60 times/min group, ROSC: 7 vs. 2, successful resuscitation: 7 vs. 2, 24-hour survival: 7 vs.1), then decreased again in the 140 times/min group (the animals that ROSC, successfully recovered and survived for 24 hours were 3, 3, and 2, respectively). Transmission electron microscopy revealed that in the 60, 80, and 140 times/min groups, nuclear membranes in cerebral tissue were irregular and incomplete, nucleoli were indistinct, and mitochondria were swollen with reduced cristae and abnormal morphology. In contrast, the 100 times/min and 120 times/min groups exhibited significantly attenuated ultrastructural damage.
Conclusions: Among the tested chest compression rates of 60-140 times/min, a chest compressions frequency of 120 times/min is the most favorable hemodynamic profile and outcomes during CPR in a porcine CA model. However, due to the wide spacing between groups, further investigation is needed to determine the optimal compression rate range more precisely.