Harmonic-Constrained Three-Level Optimized Pulse Patterns for Grid-Connected Converters With $LCL$ Filters

IF 4.5 2区 工程技术 Q2 ENGINEERING, ELECTRICAL & ELECTRONIC
Shirin Rahmanpour;Petros Karamanakos;Tobias Geyer
{"title":"Harmonic-Constrained Three-Level Optimized Pulse Patterns for Grid-Connected Converters With $LCL$ Filters","authors":"Shirin Rahmanpour;Petros Karamanakos;Tobias Geyer","doi":"10.1109/TIA.2025.3561700","DOIUrl":null,"url":null,"abstract":"This paper presents the computation of three-level optimized pulse patterns (OPPs) for converters connected to the grid via <inline-formula><tex-math>$LCL$</tex-math></inline-formula> filters. To this aim, the conventional OPP optimization problem is reformulated to account for the transfer function from the switching signal harmonics to the grid current harmonics. In addition, by incorporating constraints on grid current harmonics into the proposed OPP optimization problem, compliance with harmonic grid standards is ensured. Moreover, the restrictions that are typically imposed on multilevel switching signals, i.e., quarter-wave symmetry and unipolar switch positions, are relaxed in the proposed problem. This relaxation enables a reduction in current harmonic distortions within certain modulation intervals compared to conventional OPPs that do not limit grid current harmonics. The presented numerical results and real-time tests demonstrate the superior harmonic performance of the proposed harmonic-constrained relaxed OPPs, outperforming not only conventional modulation methods, such as space vector modulation (SVM), but also selective harmonic elimination (SHE) and conventional OPPs. Finally, further investigations reveal that the proposed OPPs maintain compliance with harmonic grid standards, even under variations in system parameters or when the <inline-formula><tex-math>$LCL$</tex-math></inline-formula> filter is downsized.","PeriodicalId":13337,"journal":{"name":"IEEE Transactions on Industry Applications","volume":"61 5","pages":"7481-7492"},"PeriodicalIF":4.5000,"publicationDate":"2025-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10969138","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Industry Applications","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10969138/","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

This paper presents the computation of three-level optimized pulse patterns (OPPs) for converters connected to the grid via $LCL$ filters. To this aim, the conventional OPP optimization problem is reformulated to account for the transfer function from the switching signal harmonics to the grid current harmonics. In addition, by incorporating constraints on grid current harmonics into the proposed OPP optimization problem, compliance with harmonic grid standards is ensured. Moreover, the restrictions that are typically imposed on multilevel switching signals, i.e., quarter-wave symmetry and unipolar switch positions, are relaxed in the proposed problem. This relaxation enables a reduction in current harmonic distortions within certain modulation intervals compared to conventional OPPs that do not limit grid current harmonics. The presented numerical results and real-time tests demonstrate the superior harmonic performance of the proposed harmonic-constrained relaxed OPPs, outperforming not only conventional modulation methods, such as space vector modulation (SVM), but also selective harmonic elimination (SHE) and conventional OPPs. Finally, further investigations reveal that the proposed OPPs maintain compliance with harmonic grid standards, even under variations in system parameters or when the $LCL$ filter is downsized.
带LCL滤波器并网变流器谐波约束三电平优化脉冲模式
本文介绍了通过LCL滤波器与电网连接的变流器的三电平优化脉冲模式(opp)的计算。为此,将传统的OPP优化问题重新表述为考虑开关信号谐波到电网电流谐波的传递函数。此外,通过将电网电流谐波约束纳入所提出的OPP优化问题,保证了OPP优化符合电网谐波标准。此外,通常施加于多电平开关信号的限制,即四分之一波对称性和单极开关位置,在提出的问题中被放宽。与不限制电网电流谐波的传统opp相比,这种松弛可以在一定的调制间隔内减少电流谐波畸变。数值结果和实时测试结果表明,所提出的谐波约束放松OPPs具有优越的谐波性能,不仅优于空间矢量调制(SVM)等传统调制方法,而且优于选择性谐波消除(SHE)和传统的OPPs。最后,进一步的研究表明,即使在系统参数变化或$LCL$滤波器缩小的情况下,拟议的opp仍符合谐波电网标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Industry Applications
IEEE Transactions on Industry Applications 工程技术-工程:电子与电气
CiteScore
9.90
自引率
9.10%
发文量
747
审稿时长
3.3 months
期刊介绍: The scope of the IEEE Transactions on Industry Applications includes all scope items of the IEEE Industry Applications Society, that is, the advancement of the theory and practice of electrical and electronic engineering in the development, design, manufacture, and application of electrical systems, apparatus, devices, and controls to the processes and equipment of industry and commerce; the promotion of safe, reliable, and economic installations; industry leadership in energy conservation and environmental, health, and safety issues; the creation of voluntary engineering standards and recommended practices; and the professional development of its membership.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信