Chen Shen, Lu Ma, Ping Xu, Xinyu Xia, Guanjie Chen, Deyu Gu, Xiaoqing Li
{"title":"[Design and application of a ventilator circuit interface protective device for weaning].","authors":"Chen Shen, Lu Ma, Ping Xu, Xinyu Xia, Guanjie Chen, Deyu Gu, Xiaoqing Li","doi":"10.3760/cma.j.cn121430-20240704-00563","DOIUrl":null,"url":null,"abstract":"<p><p>With the continuous advancement and innovation in medical equipment technology, the transition between high-flow oxygen therapy, non-invasive ventilation, and invasive ventilation can be easily achieved by adjusting the ventilation mode of ventilators. During the weaning phase for tracheotomized patients, it is necessary to disconnect the ventilator circuit, change the ventilator mode, and gradually extend the weaning time to achieve complete ventilator liberation. During the weaning process, due to patients' excessive dependence on the ventilator, there may be situations where respiratory endpoints and Y-connectors of the ventilator are reconnected for invasive ventilation. However, during the weaning process, the Y-connector and expiratory end connectors are exposed to the air, which cannot ensure the tightness of the ventilator circuit, easily increasing the probability of ventilator circuit contamination and subsequently the risk of ventilator-associated pneumonia (VAP). To overcome these issues, the research team of department of critical care medicine of Zhongda Hospital Southeast University has designed a ventilator circuit interface protective device for weaning and has obtained a National Utility Model Patent of China (ZL 2023 2 1453385.8). The main body of the protective device is a Y-connector plug, consisting of multiple components, including a sealing piece, a protective cover, a sealing plug, an interface 1 (connects with the patient's tracheal tube), an interface 2 (connects with the respiratory branch of the ventilator), and an interface 3 (connects with the expiratory branch of the ventilator), featuring a unique design and easy operation. During the patient's weaning training process, the interface 1 and interface 2 is disconnected from the patient's tracheal tube and respiratory branch, respectively. The interface 1 is plugged with a stopper, and the interface 2 is covered with a protective cover to ensure the tightness of the expiratory branch and Y-connector of the ventilator. During the period when the patient is using the ventilator, the protective cover and plug are removed, and connecting them together ensures the tightness of the device itself, reducing the incidence of VAP caused by ventilator circuit contamination, avoiding nosocomial infections, and shortening the prolonged use of invasive ventilation, increased complication rate, extended hospital stay, and increased medical cost associated with weaning.</p>","PeriodicalId":24079,"journal":{"name":"Zhonghua wei zhong bing ji jiu yi xue","volume":"37 4","pages":"391-393"},"PeriodicalIF":0.0000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhonghua wei zhong bing ji jiu yi xue","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3760/cma.j.cn121430-20240704-00563","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
With the continuous advancement and innovation in medical equipment technology, the transition between high-flow oxygen therapy, non-invasive ventilation, and invasive ventilation can be easily achieved by adjusting the ventilation mode of ventilators. During the weaning phase for tracheotomized patients, it is necessary to disconnect the ventilator circuit, change the ventilator mode, and gradually extend the weaning time to achieve complete ventilator liberation. During the weaning process, due to patients' excessive dependence on the ventilator, there may be situations where respiratory endpoints and Y-connectors of the ventilator are reconnected for invasive ventilation. However, during the weaning process, the Y-connector and expiratory end connectors are exposed to the air, which cannot ensure the tightness of the ventilator circuit, easily increasing the probability of ventilator circuit contamination and subsequently the risk of ventilator-associated pneumonia (VAP). To overcome these issues, the research team of department of critical care medicine of Zhongda Hospital Southeast University has designed a ventilator circuit interface protective device for weaning and has obtained a National Utility Model Patent of China (ZL 2023 2 1453385.8). The main body of the protective device is a Y-connector plug, consisting of multiple components, including a sealing piece, a protective cover, a sealing plug, an interface 1 (connects with the patient's tracheal tube), an interface 2 (connects with the respiratory branch of the ventilator), and an interface 3 (connects with the expiratory branch of the ventilator), featuring a unique design and easy operation. During the patient's weaning training process, the interface 1 and interface 2 is disconnected from the patient's tracheal tube and respiratory branch, respectively. The interface 1 is plugged with a stopper, and the interface 2 is covered with a protective cover to ensure the tightness of the expiratory branch and Y-connector of the ventilator. During the period when the patient is using the ventilator, the protective cover and plug are removed, and connecting them together ensures the tightness of the device itself, reducing the incidence of VAP caused by ventilator circuit contamination, avoiding nosocomial infections, and shortening the prolonged use of invasive ventilation, increased complication rate, extended hospital stay, and increased medical cost associated with weaning.