Analytical and clinical evaluation of an automated high-sensitivity cardiac troponin I assay for whole blood.

IF 3.7 2区 医学 Q1 MEDICAL LABORATORY TECHNOLOGY
Jin-Xing Yu, Kai Cui, Yang Li, Fang-Fang Yang, Fen Xu, Zhou Zhou, Ya-Hui Lin
{"title":"Analytical and clinical evaluation of an automated high-sensitivity cardiac troponin I assay for whole blood.","authors":"Jin-Xing Yu, Kai Cui, Yang Li, Fang-Fang Yang, Fen Xu, Zhou Zhou, Ya-Hui Lin","doi":"10.1515/cclm-2025-0143","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate the performance of the iStar high-sensitivity cardiac troponin I (hs-cTnI) assay, focusing on its sensitivity, precision, linearity, and consistency with plasma samples, and to establish sex-specific 99th percentile upper reference limits.</p><p><strong>Methods: </strong>The iStar hs-cTnI assay was assessed using the Drawray iStar 500 analyzer. Key performance metrics such as the limits of blank (LoB), detection (LoD) and quantitation (LoQ), precision, linearity, and agreement between sample types were evaluated according to Clinical and Laboratory Standards Institute (CLSI) guidelines. A methodological comparison was performed with the Abbott ARCHITECT hs-cTnI assay, and cross-reactivity with others troponins was assessed.</p><p><strong>Results: </strong>The iStar hs-cTnI assay demonstrated robust sensitivity with a LoB of 0.09 ng/L and LoD of 0.31 ng/L. The LoQ was 0.79 ng/L for 20 % coefficient of variation (CV) and 1.85 ng/L for 10 % CV. Precision testing revealed CVs of 1.4-4.8 % near the 99th percentile upper reference limit (URL). The assay exhibited excellent linearity (r=1.00) and high agreement between whole blood and plasma samples (slope=0.936). Methodological comparison with the Abbott ARCHITECT hs-cTnI showed a high correlation coefficient of 0.983. Cross-reactivity with skeletal muscle troponin I, cardiac troponin C, and cardiac troponin T was negligible. In healthy individuals, the overall 99th percentile URL was 16 ng/L, with sex-specific values of 18 ng/L for males and 14 ng/L for females.</p><p><strong>Conclusions: </strong>The iStar hs-cTnI assay demonstrates high sensitivity and precision, supporting it suitable for the rapid diagnosis of acute myocardial infarction using whole blood samples. Its high agreement with plasma and established sex-specific URL support its potential for clinical use in acute coronary syndrome management.</p>","PeriodicalId":10390,"journal":{"name":"Clinical chemistry and laboratory medicine","volume":" ","pages":""},"PeriodicalIF":3.7000,"publicationDate":"2025-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical chemistry and laboratory medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1515/cclm-2025-0143","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To evaluate the performance of the iStar high-sensitivity cardiac troponin I (hs-cTnI) assay, focusing on its sensitivity, precision, linearity, and consistency with plasma samples, and to establish sex-specific 99th percentile upper reference limits.

Methods: The iStar hs-cTnI assay was assessed using the Drawray iStar 500 analyzer. Key performance metrics such as the limits of blank (LoB), detection (LoD) and quantitation (LoQ), precision, linearity, and agreement between sample types were evaluated according to Clinical and Laboratory Standards Institute (CLSI) guidelines. A methodological comparison was performed with the Abbott ARCHITECT hs-cTnI assay, and cross-reactivity with others troponins was assessed.

Results: The iStar hs-cTnI assay demonstrated robust sensitivity with a LoB of 0.09 ng/L and LoD of 0.31 ng/L. The LoQ was 0.79 ng/L for 20 % coefficient of variation (CV) and 1.85 ng/L for 10 % CV. Precision testing revealed CVs of 1.4-4.8 % near the 99th percentile upper reference limit (URL). The assay exhibited excellent linearity (r=1.00) and high agreement between whole blood and plasma samples (slope=0.936). Methodological comparison with the Abbott ARCHITECT hs-cTnI showed a high correlation coefficient of 0.983. Cross-reactivity with skeletal muscle troponin I, cardiac troponin C, and cardiac troponin T was negligible. In healthy individuals, the overall 99th percentile URL was 16 ng/L, with sex-specific values of 18 ng/L for males and 14 ng/L for females.

Conclusions: The iStar hs-cTnI assay demonstrates high sensitivity and precision, supporting it suitable for the rapid diagnosis of acute myocardial infarction using whole blood samples. Its high agreement with plasma and established sex-specific URL support its potential for clinical use in acute coronary syndrome management.

全血全自动高灵敏度心肌肌钙蛋白I测定的分析和临床评价。
目的:评价iStar高灵敏度心肌肌钙蛋白I (hs-cTnI)检测的性能,重点关注其灵敏度、精密度、线性度和与血浆样品的一致性,并建立性别特异性的第99百分位上限参考限。方法:采用draway iStar 500分析仪对iStar hs-cTnI法进行评价。关键性能指标,如空白限(LoB)、检测限(LoD)和定量限(LoQ)、精密度、线性和样品类型之间的一致性,根据临床和实验室标准协会(CLSI)指南进行评估。与雅培ARCHITECT hs-cTnI试验进行方法学比较,并评估与其他肌钙蛋白的交叉反应性。结果:iStar hs-cTnI检测具有很强的灵敏度,LoB为0.09 ng/L, LoD为0.31 ng/L。变异系数为20% %时,LoQ为0.79 ng/L;变异系数为10% %时,LoQ为1.85 ng/L。精密度测试显示,CVs值为1.4 ~ 4.8 %,接近第99百分位参考上限(URL)。该方法具有良好的线性关系(r=1.00),全血和血浆样品之间的一致性很高(斜率=0.936)。与Abbott ARCHITECT hs-cTnI的方法学比较,相关系数为0.983。与骨骼肌肌钙蛋白I、心肌肌钙蛋白C和心肌肌钙蛋白T的交叉反应性可忽略不计。在健康个体中,总体第99百分位URL为16 ng/L,男性为18 ng/L,女性为14 ng/L。结论:iStar hs-cTnI检测具有较高的灵敏度和精密度,适用于全血快速诊断急性心肌梗死。它与血浆和已建立的性别特异性URL高度一致,支持其在急性冠状动脉综合征治疗中的临床应用潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Clinical chemistry and laboratory medicine
Clinical chemistry and laboratory medicine 医学-医学实验技术
CiteScore
11.30
自引率
16.20%
发文量
306
审稿时长
3 months
期刊介绍: Clinical Chemistry and Laboratory Medicine (CCLM) publishes articles on novel teaching and training methods applicable to laboratory medicine. CCLM welcomes contributions on the progress in fundamental and applied research and cutting-edge clinical laboratory medicine. It is one of the leading journals in the field, with an impact factor over 3. CCLM is issued monthly, and it is published in print and electronically. CCLM is the official journal of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) and publishes regularly EFLM recommendations and news. CCLM is the official journal of the National Societies from Austria (ÖGLMKC); Belgium (RBSLM); Germany (DGKL); Hungary (MLDT); Ireland (ACBI); Italy (SIBioC); Portugal (SPML); and Slovenia (SZKK); and it is affiliated to AACB (Australia) and SFBC (France). Topics: - clinical biochemistry - clinical genomics and molecular biology - clinical haematology and coagulation - clinical immunology and autoimmunity - clinical microbiology - drug monitoring and analysis - evaluation of diagnostic biomarkers - disease-oriented topics (cardiovascular disease, cancer diagnostics, diabetes) - new reagents, instrumentation and technologies - new methodologies - reference materials and methods - reference values and decision limits - quality and safety in laboratory medicine - translational laboratory medicine - clinical metrology Follow @cclm_degruyter on Twitter!
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信