Ambulatory monitoring of the ST segment, using direct-recording Holter systems.

Medical instrumentation Pub Date : 1988-02-01
J Brose, G Flachenecker, A Frey
{"title":"Ambulatory monitoring of the ST segment, using direct-recording Holter systems.","authors":"J Brose,&nbsp;G Flachenecker,&nbsp;A Frey","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Direct-recording ambulatory electrocardiographic monitoring systems may produce serious errors not only because of their restricted bandwidth, but even more because of the \"half-wavelength-to-head-contact effect.\" This article describes an easy measurement procedure and a mathematic model of the storage medium. The frequency response is calculated by way of five data from a single measurement. Some errors of typical recorders are discussed with the help of synthesized electrocardiographs. Measurements by six different recorders are listed.</p>","PeriodicalId":76133,"journal":{"name":"Medical instrumentation","volume":"22 1","pages":"2-11"},"PeriodicalIF":0.0000,"publicationDate":"1988-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical instrumentation","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Direct-recording ambulatory electrocardiographic monitoring systems may produce serious errors not only because of their restricted bandwidth, but even more because of the "half-wavelength-to-head-contact effect." This article describes an easy measurement procedure and a mathematic model of the storage medium. The frequency response is calculated by way of five data from a single measurement. Some errors of typical recorders are discussed with the help of synthesized electrocardiographs. Measurements by six different recorders are listed.

动态监测ST段,使用直接记录动态心电图系统。
直接记录的动态心电图监测系统可能会产生严重的错误,这不仅是因为它们的带宽有限,更重要的是由于“半波长到头部接触效应”。本文介绍了一种简便的测量方法和存储介质的数学模型。频率响应是通过一次测量的五个数据来计算的。结合合成心电图仪,讨论了典型记录仪的一些误差。列出了六种不同记录仪的测量值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信