Posterior Wall Involvement During Pulmonary Vein Isolation Using the Farapulse System.

IF 1.7 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Journal of Arrhythmia Pub Date : 2025-08-07 eCollection Date: 2025-08-01 DOI:10.1002/joa3.70171
Maria Teresa Izquierdo de Francisco, Josep Navarro-Manchon, Oscar Cano Perez, Javier Navarrete Navarro, Carmen Arveras Martinez, Fransciso Javier Chorro Gasco, Luis Martinez-Dolz, Joaquin Osca Asensi
{"title":"Posterior Wall Involvement During Pulmonary Vein Isolation Using the Farapulse System.","authors":"Maria Teresa Izquierdo de Francisco, Josep Navarro-Manchon, Oscar Cano Perez, Javier Navarrete Navarro, Carmen Arveras Martinez, Fransciso Javier Chorro Gasco, Luis Martinez-Dolz, Joaquin Osca Asensi","doi":"10.1002/joa3.70171","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>First approved PFA (Pulsed-Field-Ablation) system for pulmonary vein isolation (PVI) has been Farapulse PFA system. The aim was to assess the characteristics of the lesion made by the Farapulse system and its influence on the clinical results.</p><p><strong>Methods: </strong>First 76 consecutive patients referred for PVI and treated with the Farapulse PFA system were included. A voltage and an activation map were performed before and after PVI. An imaginary middle line was measured between the two carinas. Fusion on the posterior wall was defined when the contralateral ablation areas were connected. We arbitrarily defined a narrow corridor as one that measured < 20 mm of healthy tissue (voltage > 0.5 mV).</p><p><strong>Results: </strong>Post-PVI mapping revealed an unexpected narrow corridor in the posterior wall in 12 (15%) and fusion in 18 (23%) patients. The multivariate analysis revealed that the only independent predictor was the length of the middle inter-carinas line. The length of the middle posterior line was significantly shorter in patients with affectation of the posterior wall (62 ± 2 vs. 71 ± 3 mm, <i>p</i> = 0.0001). ROC curve showed that a middle line cutoff value of 65 mm offered a sensitivity and specificity of 80% and 70% (AUC: 0.82; 95% CI: 0.59-0.84). A corridor < 10 mm is associated with slow conduction velocity below 0.7 m/s, but narrow corridor or fusion were not associated with atrial fibrillation recurrences.</p><p><strong>Conclusions: </strong>30 (40%) patients showed narrow corridor or fusion on the posterior wall. The only independent predictor was the length of the middle inter-carina line.</p>","PeriodicalId":15174,"journal":{"name":"Journal of Arrhythmia","volume":"41 4","pages":"e70171"},"PeriodicalIF":1.7000,"publicationDate":"2025-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12331866/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Arrhythmia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/joa3.70171","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/8/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: First approved PFA (Pulsed-Field-Ablation) system for pulmonary vein isolation (PVI) has been Farapulse PFA system. The aim was to assess the characteristics of the lesion made by the Farapulse system and its influence on the clinical results.

Methods: First 76 consecutive patients referred for PVI and treated with the Farapulse PFA system were included. A voltage and an activation map were performed before and after PVI. An imaginary middle line was measured between the two carinas. Fusion on the posterior wall was defined when the contralateral ablation areas were connected. We arbitrarily defined a narrow corridor as one that measured < 20 mm of healthy tissue (voltage > 0.5 mV).

Results: Post-PVI mapping revealed an unexpected narrow corridor in the posterior wall in 12 (15%) and fusion in 18 (23%) patients. The multivariate analysis revealed that the only independent predictor was the length of the middle inter-carinas line. The length of the middle posterior line was significantly shorter in patients with affectation of the posterior wall (62 ± 2 vs. 71 ± 3 mm, p = 0.0001). ROC curve showed that a middle line cutoff value of 65 mm offered a sensitivity and specificity of 80% and 70% (AUC: 0.82; 95% CI: 0.59-0.84). A corridor < 10 mm is associated with slow conduction velocity below 0.7 m/s, but narrow corridor or fusion were not associated with atrial fibrillation recurrences.

Conclusions: 30 (40%) patients showed narrow corridor or fusion on the posterior wall. The only independent predictor was the length of the middle inter-carina line.

Abstract Image

Abstract Image

Abstract Image

使用farappulse系统隔离肺静脉时累及后壁。
背景:第一个批准用于肺静脉隔离(PVI)的PFA(脉冲场消融)系统是Farapulse PFA系统。目的是评估Farapulse系统病变的特征及其对临床结果的影响。方法:采用Farapulse PFA系统治疗PVI患者76例。PVI前后分别测量电压和激活图。在两个隆穴之间测量了一条假想的中线。当对侧消融区连接时,确定后壁融合。我们任意定义了一个狭窄的走廊,测量0.5毫伏)。结果:pvi后定位显示12例(15%)患者后壁出现意外狭窄通道,18例(23%)患者融合。多变量分析显示,唯一的独立预测因子是中间隆突线的长度。后壁畸形患者的后中线长度明显较短(62±2 vs 71±3 mm, p = 0.0001)。ROC曲线显示,65 mm的中线截断值的敏感性和特异性分别为80%和70% (AUC: 0.82;95% ci: 0.59-0.84)。结论:30例(40%)患者表现为后壁狭窄或融合。唯一的独立预测因子是中间隆突线的长度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Arrhythmia
Journal of Arrhythmia CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.90
自引率
10.00%
发文量
127
审稿时长
45 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信