Extraction of a TASER 7 Barb Embedded in the Supraorbital Frontal Bone: A Clinical Case Report.

Eplasty Pub Date : 2025-07-08 eCollection Date: 2025-01-01
Benjamin B Scott, José Antonio Arellano, Hilary Y Liu, Francesco M Egro
{"title":"Extraction of a TASER 7 Barb Embedded in the Supraorbital Frontal Bone: A Clinical Case Report.","authors":"Benjamin B Scott, José Antonio Arellano, Hilary Y Liu, Francesco M Egro","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Hand-held conducted energy devices, such as the TASER 7 (Axon Enterprise, Inc), are commonly used by law enforcement as a method of \"non-lethal\" force. However, their use may result in serious injuries. The authors report a case where a TASER 7 barb became embedded in the left supraorbital frontal bone during a field incident. Initial removal attempts were unsuccessful when the cylindrical cartridge broke off. Ultimately, the barb was successfully removed at bedside with a Kocher clamp and firm, constant in-line traction under local anesthesia at a tertiary hospital. This case highlights the potential complications associated with conducted energy devices and provides a bedside removal technique that avoids the need for operative intervention.</p>","PeriodicalId":93993,"journal":{"name":"Eplasty","volume":"25 ","pages":"e25"},"PeriodicalIF":0.0000,"publicationDate":"2025-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12331017/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eplasty","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Hand-held conducted energy devices, such as the TASER 7 (Axon Enterprise, Inc), are commonly used by law enforcement as a method of "non-lethal" force. However, their use may result in serious injuries. The authors report a case where a TASER 7 barb became embedded in the left supraorbital frontal bone during a field incident. Initial removal attempts were unsuccessful when the cylindrical cartridge broke off. Ultimately, the barb was successfully removed at bedside with a Kocher clamp and firm, constant in-line traction under local anesthesia at a tertiary hospital. This case highlights the potential complications associated with conducted energy devices and provides a bedside removal technique that avoids the need for operative intervention.

拔除嵌入眶上额骨的泰瑟7倒刺1例临床报告。
手持传导能量装置,如TASER 7 (Axon Enterprise, Inc .),通常被执法部门用作“非致命”武力的方法。然而,它们的使用可能会导致严重的伤害。作者报告了一例泰瑟7倒钩在一次野外事故中嵌入左眶上额骨。当圆柱形药筒破裂时,最初的移除尝试没有成功。最终,在一家三级医院,在局部麻醉下,在床边用Kocher钳和牢固、持续的在线牵引成功地取出了倒钩。本病例强调了与传导能量装置相关的潜在并发症,并提供了一种床边移除技术,避免了手术干预的需要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信