{"title":"Non-invasive SpO2/FiO2 ratio (SFR) as surrogate for PaO2/FiO2 ratio (PFR): A scoping review.","authors":"Madhura Reddy, Malavika Kulkarni, Sushma Thimmaiah Kanakalakshmi, Laxmi Shenoy, Rama Rani KrishnaBhat","doi":"10.2478/jccm-2025-0024","DOIUrl":null,"url":null,"abstract":"<p><p>Patient oxygenation significantly impacts clinical outcomes, and continuous monitoring is essential, especially in critical care settings where hypoxia is the leading cause of mortality. PFR (PaO2/FiO2 ratio or P/F ratio) is an invasive method for measuring oxygenation requiring arterial blood gas (ABG) sampling, however it carries complications making non-invasive methods more desirable. SFR (SpO2/FiO2 ratio or S/F ratio), a non-invasive tool based on pulse oximetry, provides a cost-effective and rapid way to monitor oxygenation status, especially in settings where advanced methods are unavailable. A total of 575 articles were screened from databases including Web of Science, Scopus, PubMed, and CINAHL, with 32 articles meeting the inclusion criteria for this scoping review wherein SFR was used as a surrogate for PFR and a diagnostic tool for acute lung injury and ARDS. A total of 81,637 patient records were analyzed, including ABG values, pulse oximetry readings, mechanical ventilator settings, and patient diagnoses. The study population included adults, pediatric patients, and neonates admitted to critical care units, with common diagnoses including acute hypoxemic respiratory failure, ARDS, and COVID-19. In the context of COVID-19, SFR was used to predict the need for mechanical ventilation, with a cut-off of 300 indicating a threshold for imminent ventilation requirement. The studies demonstrated statistically significant sensitivity and specificity for SFR, highlighting its utility as a non-invasive tool for assessing oxygenation status. SFR has shown potential as a reliable non-invasive surrogate for determining oxygenation status across all populations.</p>","PeriodicalId":44227,"journal":{"name":"Journal of Critical Care Medicine","volume":"11 3","pages":"221-232"},"PeriodicalIF":1.7000,"publicationDate":"2025-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12321259/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Critical Care Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/jccm-2025-0024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/7/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Patient oxygenation significantly impacts clinical outcomes, and continuous monitoring is essential, especially in critical care settings where hypoxia is the leading cause of mortality. PFR (PaO2/FiO2 ratio or P/F ratio) is an invasive method for measuring oxygenation requiring arterial blood gas (ABG) sampling, however it carries complications making non-invasive methods more desirable. SFR (SpO2/FiO2 ratio or S/F ratio), a non-invasive tool based on pulse oximetry, provides a cost-effective and rapid way to monitor oxygenation status, especially in settings where advanced methods are unavailable. A total of 575 articles were screened from databases including Web of Science, Scopus, PubMed, and CINAHL, with 32 articles meeting the inclusion criteria for this scoping review wherein SFR was used as a surrogate for PFR and a diagnostic tool for acute lung injury and ARDS. A total of 81,637 patient records were analyzed, including ABG values, pulse oximetry readings, mechanical ventilator settings, and patient diagnoses. The study population included adults, pediatric patients, and neonates admitted to critical care units, with common diagnoses including acute hypoxemic respiratory failure, ARDS, and COVID-19. In the context of COVID-19, SFR was used to predict the need for mechanical ventilation, with a cut-off of 300 indicating a threshold for imminent ventilation requirement. The studies demonstrated statistically significant sensitivity and specificity for SFR, highlighting its utility as a non-invasive tool for assessing oxygenation status. SFR has shown potential as a reliable non-invasive surrogate for determining oxygenation status across all populations.
患者氧合显著影响临床结果,持续监测是必不可少的,特别是在缺氧是主要死亡原因的重症监护环境中。PFR (PaO2/FiO2比率或P/F比率)是一种需要动脉血气(ABG)采样来测量氧合的侵入性方法,然而它带有并发症,使得非侵入性方法更可取。SFR (SpO2/FiO2比率或S/F比率)是一种基于脉搏血氧仪的无创工具,提供了一种经济高效且快速的监测氧合状态的方法,特别是在无法使用先进方法的情况下。从Web of Science、Scopus、PubMed和CINAHL等数据库中共筛选了575篇文章,其中32篇文章符合本综述的纳入标准,其中SFR被用作PFR的替代指标和急性肺损伤和ARDS的诊断工具。共分析了81637例患者记录,包括血气测定值、脉搏血氧仪读数、机械呼吸机设置和患者诊断。研究人群包括成人、儿科患者和入住重症监护病房的新生儿,常见的诊断包括急性低氧性呼吸衰竭、ARDS和COVID-19。在COVID-19的背景下,SFR用于预测机械通气需求,截断值为300表示即将需要通气的阈值。这些研究表明,SFR的敏感性和特异性具有统计学意义,突出了其作为评估氧合状态的非侵入性工具的实用性。SFR已显示出作为确定所有人群氧合状态的可靠的非侵入性替代指标的潜力。