{"title":"Enabling in vivo comparisons of different four-dimensional magnetic resonance imaging sequences for radiotherapy guidance using visual biofeedback","authors":"Katrinus Keijnemans , Tim Schakel , Bastien Lecoeur , Pim T.S. Borman , William A. Hall , Bas W. Raaymakers , Andreas Wetscherek , Eric S. Paulson , Martin F. Fast","doi":"10.1016/j.phro.2025.100815","DOIUrl":null,"url":null,"abstract":"<div><h3>Background and Purpose:</h3><div>Managing respiratory motion is essential for effective radiotherapy in the abdominothoracic regions. Respiratory-correlated four-dimensional magnetic resonance imaging (4D-MRI) can provide accurate motion estimation to help define treatment volumes for adaptive radiotherapy. However, validating and comparing 4D-MRI sequences in vivo is challenging due to the presence of breathing variability. This study combines visual biofeedback (VBF) with 4D-MRI sequences to facilitate in vivo comparisons.</div></div><div><h3>Materials and Methods:</h3><div>Fourteen healthy volunteers and one patient were scanned on a 1.5 T Unity MR-linear accelerator (Elekta AB, Stockholm, Sweden) at two institutions. A radial stack-of-stars (SoS), a simultaneous multi-slice (SMS), and a Cartesian acquisition with spiral ordering (CASPR) 4D-MRI sequence were acquired. These acquisitions were performed without and with VBF based on an interleaved one-dimensional respiratory navigator (1D-RNAV) acquisition. Breathing variability across sequences was quantified using 1D-RNAV-derived breathing waveforms. Reconstructed 4D-MRI data were used to extract the motion amplitude, which was compared intra-volunteer across sequences and to the amplitudes of the breathing waveforms.</div></div><div><h3>Results:</h3><div>Breathing variability across sequences decreased by 37% (amplitude, <em>p</em> <span><math><mo>=</mo></math></span> 0.039) and 64% (period, <em>p</em> <span><math><mo><</mo></math></span> 0.003), and the median intra-volunteer 4D-MRI-derived motion amplitude agreement improved from 3.5 mm to 1.8 mm (<em>p</em> <span><math><mo>=</mo></math></span> 0.064) across sequences due to VBF guidance. Four-dimensional MRI-derived amplitudes were smaller than breathing waveform amplitudes, with median differences of -31% (SoS), -17% (SMS), and -9% (CASPR). The average breathing waveform amplitude was 8% larger than instructed.</div></div><div><h3>Conclusions:</h3><div>This methodology enables in vivo comparisons of 4D-MRI sequences for adaptive radiotherapy, with guidance improving anatomical consistency and ensuring more reliable comparisons.</div></div>","PeriodicalId":36850,"journal":{"name":"Physics and Imaging in Radiation Oncology","volume":"35 ","pages":"Article 100815"},"PeriodicalIF":3.3000,"publicationDate":"2025-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics and Imaging in Radiation Oncology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2405631625001204","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background and Purpose:
Managing respiratory motion is essential for effective radiotherapy in the abdominothoracic regions. Respiratory-correlated four-dimensional magnetic resonance imaging (4D-MRI) can provide accurate motion estimation to help define treatment volumes for adaptive radiotherapy. However, validating and comparing 4D-MRI sequences in vivo is challenging due to the presence of breathing variability. This study combines visual biofeedback (VBF) with 4D-MRI sequences to facilitate in vivo comparisons.
Materials and Methods:
Fourteen healthy volunteers and one patient were scanned on a 1.5 T Unity MR-linear accelerator (Elekta AB, Stockholm, Sweden) at two institutions. A radial stack-of-stars (SoS), a simultaneous multi-slice (SMS), and a Cartesian acquisition with spiral ordering (CASPR) 4D-MRI sequence were acquired. These acquisitions were performed without and with VBF based on an interleaved one-dimensional respiratory navigator (1D-RNAV) acquisition. Breathing variability across sequences was quantified using 1D-RNAV-derived breathing waveforms. Reconstructed 4D-MRI data were used to extract the motion amplitude, which was compared intra-volunteer across sequences and to the amplitudes of the breathing waveforms.
Results:
Breathing variability across sequences decreased by 37% (amplitude, p 0.039) and 64% (period, p 0.003), and the median intra-volunteer 4D-MRI-derived motion amplitude agreement improved from 3.5 mm to 1.8 mm (p 0.064) across sequences due to VBF guidance. Four-dimensional MRI-derived amplitudes were smaller than breathing waveform amplitudes, with median differences of -31% (SoS), -17% (SMS), and -9% (CASPR). The average breathing waveform amplitude was 8% larger than instructed.
Conclusions:
This methodology enables in vivo comparisons of 4D-MRI sequences for adaptive radiotherapy, with guidance improving anatomical consistency and ensuring more reliable comparisons.