Evaluating the accuracy of 3D printing and finite element analysis in transcatheter aortic valveimplantation: a comparative study against post-TAVI CT imaging.

Q3 Engineering
Fabrizio Crascì, Stefano Cannata, Caterina Gandolfo, Salvatore Pasta
{"title":"Evaluating the accuracy of 3D printing and finite element analysis in transcatheter aortic valveimplantation: a comparative study against post-TAVI CT imaging.","authors":"Fabrizio Crascì, Stefano Cannata, Caterina Gandolfo, Salvatore Pasta","doi":"10.1080/03091902.2025.2540127","DOIUrl":null,"url":null,"abstract":"<p><p>Transcatheter aortic valve implantation (TAVI) is now the standard treatment for aortic stenosis, offering a less invasive alternative to surgery. While 3D printing and finite element analysis (FEA) show promise for pre-procedural planning, their accuracy in predicting post-TAVI device geometry remains unclear. This study evaluates the agreement between patient-specific FEA models, 3D-printed phantoms, and post-TAVI CT imaging in replicating implanted device geometry. Ten patients treated with the SAPIEN 3 Ultra (S3) device were analysed using pre- and post-TAVI CT scans. Both FEA simulations and 3D-printed models were assessed for stent deformation and anatomical fit. Agreement was quantified using statistical tools including concordance correlation coefficient (CCC), intraclass correlation coefficient (ICC), and Bland-Altman plots. FEA showed stronger agreement with post-TAVI CT (ICC = 0.614, CCC = 0.479) than 3D printing (ICC = 0.363, CCC = 0.165), which had higher variability. While FEA closely approximated device expansion at the annular level, both methods had limitations due to material and computational assumptions. The study supports the greater reliability of FEA in pre-procedural planning, highlighting the need for further validation and standardisation.</p>","PeriodicalId":39637,"journal":{"name":"Journal of Medical Engineering and Technology","volume":" ","pages":"315-324"},"PeriodicalIF":0.0000,"publicationDate":"2025-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Engineering and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/03091902.2025.2540127","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/8/1 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

Abstract

Transcatheter aortic valve implantation (TAVI) is now the standard treatment for aortic stenosis, offering a less invasive alternative to surgery. While 3D printing and finite element analysis (FEA) show promise for pre-procedural planning, their accuracy in predicting post-TAVI device geometry remains unclear. This study evaluates the agreement between patient-specific FEA models, 3D-printed phantoms, and post-TAVI CT imaging in replicating implanted device geometry. Ten patients treated with the SAPIEN 3 Ultra (S3) device were analysed using pre- and post-TAVI CT scans. Both FEA simulations and 3D-printed models were assessed for stent deformation and anatomical fit. Agreement was quantified using statistical tools including concordance correlation coefficient (CCC), intraclass correlation coefficient (ICC), and Bland-Altman plots. FEA showed stronger agreement with post-TAVI CT (ICC = 0.614, CCC = 0.479) than 3D printing (ICC = 0.363, CCC = 0.165), which had higher variability. While FEA closely approximated device expansion at the annular level, both methods had limitations due to material and computational assumptions. The study supports the greater reliability of FEA in pre-procedural planning, highlighting the need for further validation and standardisation.

评价3D打印和有限元分析在经导管主动脉瓣置入术中的准确性:与tavi后CT成像的比较研究。
经导管主动脉瓣植入术(TAVI)是目前治疗主动脉瓣狭窄的标准方法,它比手术侵入性更小。虽然3D打印和有限元分析(FEA)显示了程序前规划的前景,但它们在预测tavi后设备几何形状方面的准确性仍不清楚。本研究评估了患者特异性FEA模型、3d打印模型和tavi后CT成像在复制植入装置几何形状方面的一致性。对10例使用SAPIEN 3 Ultra (S3)装置治疗的患者进行tavi前后CT扫描分析。FEA模拟和3d打印模型都评估了支架变形和解剖配合。使用统计工具对一致性进行量化,包括一致性相关系数(CCC)、类内相关系数(ICC)和Bland-Altman图。FEA与tavi后CT的一致性(ICC = 0.614, CCC = 0.479)高于3D打印(ICC = 0.363, CCC = 0.165),差异较大。虽然FEA近似于环形水平的器件扩展,但由于材料和计算假设,这两种方法都有局限性。该研究支持FEA在程序前计划中的更高可靠性,强调了进一步验证和标准化的必要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Medical Engineering and Technology
Journal of Medical Engineering and Technology Engineering-Biomedical Engineering
CiteScore
4.60
自引率
0.00%
发文量
77
期刊介绍: The Journal of Medical Engineering & Technology is an international, independent, multidisciplinary, bimonthly journal promoting an understanding of the physiological processes underlying disease processes and the appropriate application of technology. Features include authoritative review papers, the reporting of original research, and evaluation reports on new and existing techniques and devices. Each issue of the journal contains a comprehensive information service which provides news relevant to the world of medical technology, details of new products, book reviews, and selected contents of related journals.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书