Evaluation of a digital bismuth germanium oxide PET/CT system according to the Japanese brain tumor phantom test for 18F-fluciclovine imaging.

IF 2 4区 医学 Q3 ENGINEERING, BIOMEDICAL
Shohei Fukai, Hiromitsu Daisaki, Honoka Yoshida, Naoki Shimada, Kazuki Motegi, Atsushi Osawa, Takashi Terauchi
{"title":"Evaluation of a digital bismuth germanium oxide PET/CT system according to the Japanese brain tumor phantom test for <sup>18</sup>F-fluciclovine imaging.","authors":"Shohei Fukai, Hiromitsu Daisaki, Honoka Yoshida, Naoki Shimada, Kazuki Motegi, Atsushi Osawa, Takashi Terauchi","doi":"10.1007/s13246-025-01608-z","DOIUrl":null,"url":null,"abstract":"<p><p>The Omni Legend (GE Healthcare), equipped with a digital bismuth germanium oxide PET/CT system, has been recently developed. However, the performance of the Omni Legend without a time-of-flight (TOF) system for <sup>18</sup>F-fluciclovine imaging is still unclear. Therefore, this study evaluated the image quality of the Omni Legend according to the Japanese brain tumor phantom test (JBT) criteria, and assessed its potential use for <sup>18</sup>F-fluciclovine imaging. This study followed the JBT procedures. A brain tumor phantom, which includes six hot spheres of different diameters, was filled with an <sup>18</sup>F-fluorodeoxyglucose solution with a radioactivity concentration ratio of 3 (spheres):1 (background). PET scanning was performed using the Omni Legend with a 30-min list mode acquisition. The PET data were reconstructed using an ordered subset expectation maximization (OSEM), an OSEM with point spread function (OSEM + PSF), and a Bayesian penalized likelihood (BPL) under standard clinical parameters. The image quality was evaluated using the JBT criteria, including contrast for a 7.5-mm sphere, recovery coefficient (RC) for a 10.0-mm sphere, standardized uptake value of total background (SUV<sub>TOT</sub>), and detectability for a 7.5-mm sphere. The contrast, RC, and SUV<sub>TOT</sub> were 25.1%, 0.70, and 1.00, respectively in OSEM; 25.8%, 0.80, and 0.99 in OSEM + PSF; and 33.8%, 0.93, and 0.99 in BPL. The 7.5-mm sphere was detected by all three methods. All of the JBT criteria were satisfied, regardless of the PET image reconstruction methods. This study demonstrated that the Omni Legend without TOF satisfies all JBT criteria and has the potential to provide high-quality images in <sup>18</sup>F-fluciclovine imaging.</p>","PeriodicalId":48490,"journal":{"name":"Physical and Engineering Sciences in Medicine","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2025-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physical and Engineering Sciences in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s13246-025-01608-z","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The Omni Legend (GE Healthcare), equipped with a digital bismuth germanium oxide PET/CT system, has been recently developed. However, the performance of the Omni Legend without a time-of-flight (TOF) system for 18F-fluciclovine imaging is still unclear. Therefore, this study evaluated the image quality of the Omni Legend according to the Japanese brain tumor phantom test (JBT) criteria, and assessed its potential use for 18F-fluciclovine imaging. This study followed the JBT procedures. A brain tumor phantom, which includes six hot spheres of different diameters, was filled with an 18F-fluorodeoxyglucose solution with a radioactivity concentration ratio of 3 (spheres):1 (background). PET scanning was performed using the Omni Legend with a 30-min list mode acquisition. The PET data were reconstructed using an ordered subset expectation maximization (OSEM), an OSEM with point spread function (OSEM + PSF), and a Bayesian penalized likelihood (BPL) under standard clinical parameters. The image quality was evaluated using the JBT criteria, including contrast for a 7.5-mm sphere, recovery coefficient (RC) for a 10.0-mm sphere, standardized uptake value of total background (SUVTOT), and detectability for a 7.5-mm sphere. The contrast, RC, and SUVTOT were 25.1%, 0.70, and 1.00, respectively in OSEM; 25.8%, 0.80, and 0.99 in OSEM + PSF; and 33.8%, 0.93, and 0.99 in BPL. The 7.5-mm sphere was detected by all three methods. All of the JBT criteria were satisfied, regardless of the PET image reconstruction methods. This study demonstrated that the Omni Legend without TOF satisfies all JBT criteria and has the potential to provide high-quality images in 18F-fluciclovine imaging.

根据日本脑肿瘤幻像试验对数字氧化铋锗PET/CT系统进行18f氟化影成像评价。
最近开发了Omni Legend (GE Healthcare),配备了数字铋锗氧化物PET/CT系统。然而,在没有飞行时间(TOF)系统的情况下,Omni Legend的18f氟化成像性能仍不清楚。因此,本研究根据日本脑肿瘤幻像测试(JBT)标准评估Omni Legend的图像质量,并评估其在18f -氟化线成像中的潜在应用。本研究遵循JBT程序。用放射性浓度比为3(球体):1(背景)的18f氟脱氧葡萄糖溶液填充脑肿瘤幻象,其中包括6个不同直径的热球体。PET扫描使用Omni Legend进行30分钟列表模式采集。PET数据在标准临床参数下使用有序子集期望最大化(OSEM)、带点扩散函数的OSEM (OSEM + PSF)和贝叶斯惩罚似然(BPL)进行重构。使用JBT标准评估图像质量,包括7.5 mm球体的对比度,10.0 mm球体的恢复系数(RC),总背景的标准化摄取值(SUVTOT)和7.5 mm球体的可检测性。OSEM的对比、RC和SUVTOT分别为25.1%、0.70和1.00;OSEM + PSF分别为25.8%、0.80和0.99;BPL分别为33.8%、0.93和0.99。三种方法均能检测到7.5 mm的球体。无论采用何种PET图像重建方法,均满足JBT标准。本研究表明,不带TOF的Omni Legend符合所有JBT标准,并有可能提供高质量的18f氟化成像图像。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
8.40
自引率
4.50%
发文量
110
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信