Mageshraja Kannan, Sathiyan Saminathan, C Prasobh, Aditya Gupta, Karuppusamy Arumugam, Nithin Bhaskar, Varatharaj Chandraraj, B Shwetha, K M Ganesh
{"title":"Dosimetric comparison in various stereotactic radiosurgery modalities for trigeminal neuralgia treatment.","authors":"Mageshraja Kannan, Sathiyan Saminathan, C Prasobh, Aditya Gupta, Karuppusamy Arumugam, Nithin Bhaskar, Varatharaj Chandraraj, B Shwetha, K M Ganesh","doi":"10.1007/s12194-025-00935-w","DOIUrl":null,"url":null,"abstract":"<p><p>Trigeminal neuralgia (TN) is characterized by severe facial pain and is treated with medications, surgery, percutaneous procedures, and stereotactic radiosurgery (SRS). The Gamma Knife (GK) has historically been the gold standard for SRS in TN, with alternatives such as the CyberKnife (CK) and standard linear accelerator (LA) having recently emerged. This study compared GK, CK, and LA treatments for TN via dosimetric analysis. Twenty patients (10 right- and 10 left-sided) with TN were planned in the three modalities. Dosimetric parameters, including D<sub>Max</sub>, D<sub>Min</sub>, D<sub>Mean</sub>, D<sub>98%</sub>, D<sub>90%</sub>, D<sub>50%</sub>, D<sub>30%</sub>, and V<sub>4Gy</sub>, were evaluated. The statistical significance was assessed using paired t tests. The CK and LA plans achieved a 60 Gy target coverage comparable to the GK plan. The GK plan exhibited superior brain stem sparing and lower V<sub>4Gy</sub> compared with CK (p = 0.0013) and LA (p = 0.0001). Significant differences in D<sub>Min</sub>, D<sub>98%</sub>, D<sub>90%</sub>, D<sub>50%</sub>, and D<sub>30%</sub> were observed between GK and CK (p < 0.05) and GK and LA (p < 0.05), but not for the CK-LA comparisons. The brain stem dose parameters (D<sub>0.03 cc</sub>, D<sub>1%</sub>, and D<sub>2%</sub>) were significantly lower in the GK plan (p < 0.05). The GK exhibited better normal tissue sparing and brain stem dose distribution than CK and LA, attributable partly to its higher beam count. CK and LA require more intricate planning times. Despite the established efficacy of GK, CK and LA offer viable alternatives, underscoring the need for further research on the clinical outcomes of TN treatment in the respective modalities.</p>","PeriodicalId":46252,"journal":{"name":"Radiological Physics and Technology","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2025-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiological Physics and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12194-025-00935-w","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Trigeminal neuralgia (TN) is characterized by severe facial pain and is treated with medications, surgery, percutaneous procedures, and stereotactic radiosurgery (SRS). The Gamma Knife (GK) has historically been the gold standard for SRS in TN, with alternatives such as the CyberKnife (CK) and standard linear accelerator (LA) having recently emerged. This study compared GK, CK, and LA treatments for TN via dosimetric analysis. Twenty patients (10 right- and 10 left-sided) with TN were planned in the three modalities. Dosimetric parameters, including DMax, DMin, DMean, D98%, D90%, D50%, D30%, and V4Gy, were evaluated. The statistical significance was assessed using paired t tests. The CK and LA plans achieved a 60 Gy target coverage comparable to the GK plan. The GK plan exhibited superior brain stem sparing and lower V4Gy compared with CK (p = 0.0013) and LA (p = 0.0001). Significant differences in DMin, D98%, D90%, D50%, and D30% were observed between GK and CK (p < 0.05) and GK and LA (p < 0.05), but not for the CK-LA comparisons. The brain stem dose parameters (D0.03 cc, D1%, and D2%) were significantly lower in the GK plan (p < 0.05). The GK exhibited better normal tissue sparing and brain stem dose distribution than CK and LA, attributable partly to its higher beam count. CK and LA require more intricate planning times. Despite the established efficacy of GK, CK and LA offer viable alternatives, underscoring the need for further research on the clinical outcomes of TN treatment in the respective modalities.
期刊介绍:
The purpose of the journal Radiological Physics and Technology is to provide a forum for sharing new knowledge related to research and development in radiological science and technology, including medical physics and radiological technology in diagnostic radiology, nuclear medicine, and radiation therapy among many other radiological disciplines, as well as to contribute to progress and improvement in medical practice and patient health care.