Patient-centered outcomes of indirect CAD-CAM removable partial denture frameworks: A 2-year follow-up study.

IF 3.4 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Hend Mahmoud Hegazi, Amr Elkhadem, Ahmed Fayyad, Doaa Mahmoud Elkady, Maha Wagdy Elkerdawy, Arwa Sedky
{"title":"Patient-centered outcomes of indirect CAD-CAM removable partial denture frameworks: A 2-year follow-up study.","authors":"Hend Mahmoud Hegazi, Amr Elkhadem, Ahmed Fayyad, Doaa Mahmoud Elkady, Maha Wagdy Elkerdawy, Arwa Sedky","doi":"10.1111/jopr.14100","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to assess patient-centered outcomes of polyetheretherketone (PEEK) and cobalt chromium (CoCr) removable partial denture (RPD) frameworks, as well as to present detailed technical steps of digital designing and indirect production of metal and PEEK RPD frameworks.</p><p><strong>Materials and methods: </strong>This randomized, controlled, parallel-group clinical trial included 30 patients. The enrolled patients were partially edentulous with mandibular Kennedy Class I. They were randomly assigned to receive an indirect computer-aided design and computer-aided manufacturing (CAD-CAM) PEEK RPD as the interventional group, or an indirect CAD-CAM metallic (CoCr) RPD as the control group. Oral health-related quality of life (OHRQoL) and patient satisfaction were evaluated by the Oral Health Impact Profile questionnaire (OHIP-14) and patient satisfaction with the Lower Removable Denture Questionnaire (SLRD-Q), respectively. They were assessed at RPD insertion as a baseline (T0), 1 month (T1), 3 months (T2), 1 year (T3), and 2 years (T4) after insertion. Mann-Whitney and Friedman's tests were used for statistical analysis (p-value = 0.05).</p><p><strong>Results: </strong>All patients completed the follow-up period. No significant difference was found at all follow-up periods between both RPDs regarding both OHRQoL and patient satisfaction.</p><p><strong>Conclusion: </strong>Within the limitations of this short-term study, it can be concluded that indirect CAD-CAM PEEK and metallic RPDs are acceptable treatment options for Kennedy Class I edentulous mandibles, from the patient's perspective. Both RPDs improved OHRQoL to a degree that surpasses the minimally clinically important difference (MCID) after 2 years. Patient satisfaction improved as well.</p>","PeriodicalId":49152,"journal":{"name":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","volume":" ","pages":""},"PeriodicalIF":3.4000,"publicationDate":"2025-07-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jopr.14100","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study aimed to assess patient-centered outcomes of polyetheretherketone (PEEK) and cobalt chromium (CoCr) removable partial denture (RPD) frameworks, as well as to present detailed technical steps of digital designing and indirect production of metal and PEEK RPD frameworks.

Materials and methods: This randomized, controlled, parallel-group clinical trial included 30 patients. The enrolled patients were partially edentulous with mandibular Kennedy Class I. They were randomly assigned to receive an indirect computer-aided design and computer-aided manufacturing (CAD-CAM) PEEK RPD as the interventional group, or an indirect CAD-CAM metallic (CoCr) RPD as the control group. Oral health-related quality of life (OHRQoL) and patient satisfaction were evaluated by the Oral Health Impact Profile questionnaire (OHIP-14) and patient satisfaction with the Lower Removable Denture Questionnaire (SLRD-Q), respectively. They were assessed at RPD insertion as a baseline (T0), 1 month (T1), 3 months (T2), 1 year (T3), and 2 years (T4) after insertion. Mann-Whitney and Friedman's tests were used for statistical analysis (p-value = 0.05).

Results: All patients completed the follow-up period. No significant difference was found at all follow-up periods between both RPDs regarding both OHRQoL and patient satisfaction.

Conclusion: Within the limitations of this short-term study, it can be concluded that indirect CAD-CAM PEEK and metallic RPDs are acceptable treatment options for Kennedy Class I edentulous mandibles, from the patient's perspective. Both RPDs improved OHRQoL to a degree that surpasses the minimally clinically important difference (MCID) after 2 years. Patient satisfaction improved as well.

间接CAD-CAM可摘局部义齿框架以患者为中心的疗效:一项2年随访研究。
目的:本研究旨在评估以患者为中心的聚醚醚酮(PEEK)和钴铬(CoCr)可摘局部义齿(RPD)框架的效果,并提出金属和PEEK RPD框架数字化设计和间接生产的详细技术步骤。材料与方法:本临床试验随机、对照、平行组共30例。纳入的患者为下颌Kennedy i级部分无牙患者,他们被随机分配接受间接计算机辅助设计和计算机辅助制造(CAD-CAM) PEEK RPD作为介入组,或间接CAD-CAM金属(CoCr) RPD作为对照组。口腔健康相关生活质量(OHRQoL)和患者满意度分别通过口腔健康影响问卷(OHIP-14)和患者对下颌可摘义齿问卷(SLRD-Q)进行评估。在RPD插入后作为基线(T0)、1个月(T1)、3个月(T2)、1年(T3)和2年(T4)对患者进行评估。采用Mann-Whitney和Friedman检验进行统计学分析(p值= 0.05)。结果:所有患者均完成随访。在所有随访期间,两种rpd在OHRQoL和患者满意度方面均无显著差异。结论:在这项短期研究的限制下,从患者的角度来看,间接CAD-CAM PEEK和金属rpd是Kennedy I类无牙下颌可接受的治疗选择。两种rpd在2年后改善OHRQoL的程度都超过了最小临床重要差异(MCID)。患者满意度也有所提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.90
自引率
15.00%
发文量
171
审稿时长
6-12 weeks
期刊介绍: The Journal of Prosthodontics promotes the advanced study and practice of prosthodontics, implant, esthetic, and reconstructive dentistry. It is the official journal of the American College of Prosthodontists, the American Dental Association-recognized voice of the Specialty of Prosthodontics. The journal publishes evidence-based original scientific articles presenting information that is relevant and useful to prosthodontists. Additionally, it publishes reports of innovative techniques, new instructional methodologies, and instructive clinical reports with an interdisciplinary flair. The journal is particularly focused on promoting the study and use of cutting-edge technology and positioning prosthodontists as the early-adopters of new technology in the dental community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信