{"title":"Changes in the Surface Area and Volume of Hyflex EDM Instruments after Multiple Uses.","authors":"Neslihan Büşra Keskin, Taha Özyürek, Zeliha Uğur Aydin, Ferhat Geneci, Mert Ocak, Hakan Hamdi Çelik, Dilek Helvacioglu-Yigit","doi":"10.15644/asc59/2/1","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The aim of the study was to evaluate the surface areas and volumes of HyFlex EDM (HEDM) nickel-titanium (NiTi) files before and after multiple uses in mandibular molar root canal preparation.</p><p><strong>Materials and methods: </strong>Twelve HEDM files with sizes of 10/.05 and 25/.08 were evaluated by micro-CT before and after a single use or multiple uses in root canal preparation. The mesiobuccal and mesiolingual root canals of thirty-six human mandibular molar teeth were instrumented using twelve 10/.05 (300 rpm and 1.8 Ncm) and twelve 25/.085 Ncm) HEDM files according to the manufacturer's recommendation. HEDM files were evaluated using micro-CT at four different timelines: 1) Intact file, 2) After instrumentation of one canal, 3) After instrumentation of two canals, and 4) After instrumentation of three canals. Each group's volume and surface area were analyzed by applying Friedman's test. Each group comparison was assessed using the Wilcoxon signed-rank test with Bonferroni correction.</p><p><strong>Results: </strong>Intact HEDM 10/.05 and HEDM 25/.08 files showed significantly larger volumes and surface areas compared to the used instruments (p < 0.05).</p><p><strong>Conclusions: </strong>A significant decrease in the volume and surface area of the NiTi files was observed as the number of uses increased regardless of the file group. These findings emphasize the importance for clinicians to understand the structural changes in HEDM files during repeated use to ensure safe instrument reuse and prevent endodontic treatment failure.</p>","PeriodicalId":7154,"journal":{"name":"Acta Stomatologica Croatica","volume":"59 2","pages":"114-123"},"PeriodicalIF":1.8000,"publicationDate":"2025-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12239642/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Stomatologica Croatica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15644/asc59/2/1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The aim of the study was to evaluate the surface areas and volumes of HyFlex EDM (HEDM) nickel-titanium (NiTi) files before and after multiple uses in mandibular molar root canal preparation.

Materials and methods: Twelve HEDM files with sizes of 10/.05 and 25/.08 were evaluated by micro-CT before and after a single use or multiple uses in root canal preparation. The mesiobuccal and mesiolingual root canals of thirty-six human mandibular molar teeth were instrumented using twelve 10/.05 (300 rpm and 1.8 Ncm) and twelve 25/.085 Ncm) HEDM files according to the manufacturer's recommendation. HEDM files were evaluated using micro-CT at four different timelines: 1) Intact file, 2) After instrumentation of one canal, 3) After instrumentation of two canals, and 4) After instrumentation of three canals. Each group's volume and surface area were analyzed by applying Friedman's test. Each group comparison was assessed using the Wilcoxon signed-rank test with Bonferroni correction.

Results: Intact HEDM 10/.05 and HEDM 25/.08 files showed significantly larger volumes and surface areas compared to the used instruments (p < 0.05).

Conclusions: A significant decrease in the volume and surface area of the NiTi files was observed as the number of uses increased regardless of the file group. These findings emphasize the importance for clinicians to understand the structural changes in HEDM files during repeated use to ensure safe instrument reuse and prevent endodontic treatment failure.

Hyflex电火花加工仪器多次使用后的表面积和体积变化。
目的:研究HyFlex EDM (HEDM)镍钛(NiTi)锉在下颌磨牙根管预备中多次使用前后的表面积和体积。材料与方法:HEDM文件12个,大小为10/。05和25/。在单次或多次使用根管预备前后对08例进行micro-CT评价。对36颗人下颌磨牙的中颊根管和中舌根管进行了12.10 / 0.05的固定(300 rpm和1.8 Ncm)和12 25/.085根据制造商推荐的Ncm) HEDM文件。使用micro-CT在四个不同的时间线评估HEDM锉:1)完整锉,2)一根管预备完毕后,3)两根管预备完毕后,4)三根管预备完毕后。采用Friedman’s检验对各组的体积和表面积进行分析。采用Wilcoxon sign -rank检验和Bonferroni校正对各组比较进行评估。结果:完整的HEDM 10/。05和HEDM 25/。结论:无论何种锉组,随着使用次数的增加,观察到NiTi锉的体积和表面积都显著减少。这些发现强调了临床医生了解HEDM文件在重复使用期间的结构变化的重要性,以确保器械的安全重复使用并防止根管治疗失败。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Acta Stomatologica Croatica
Acta Stomatologica Croatica DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.40
自引率
28.60%
发文量
32
审稿时长
12 weeks
期刊介绍: The Acta Stomatologica Croatica (ASCRO) is a leading scientific non-profit journal in the field of dental, oral and cranio-facial sciences during the past 44 years in Croatia. ASCRO publishes original scientific and clinical papers, preliminary communications, case reports, book reviews, letters to the editor and news. Review articles are published by invitation from the Editor-in-Chief by acclaimed professionals in distinct fields of dental medicine. All manuscripts are subjected to peer review process.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信