Xinni Xu, Margaret Ru Xiang Zhang, Terese Huiying Low, Yew Kwang Ong
{"title":"Development and validation of odour identification tests for olfactory assessment in Singapore.","authors":"Xinni Xu, Margaret Ru Xiang Zhang, Terese Huiying Low, Yew Kwang Ong","doi":"10.47102/annals-acadmedsg.2024364","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Odour recognition is influenced by culture. Odour identification tests need to be adapted to a population to accurately assess olfactory function. This study's objectives were to validate the Singapore version of the Sniffin' Sticks (SS-Sg) and a locally-developed odour recognition test (Scentsor) for Singapore.</p><p><strong>Method: </strong>This prospective study was performed in 3 otolaryngology outpatient clinics in 3 phases (1 May to 15 November 2024). Phase 1 was a survey evaluation of 93 odour descriptors to identify familiar odour descriptors to be used in the tests (n=414); Phase 2 evaluated and finalised SS-Sg and Scentsor to ensure test odours were recognised by ≥75% of healthy controls (n=130); and Phase 3 validated both tests on healthy controls (n=473) to obtain normative data, to determine test-retest reliability (n=50), and to assess the ability to distinguish patients with olfactory loss (n=67).</p><p><strong>Results: </strong>In Phase 1, the unmodified SS blue and purple sets had 15/32 (46.9%) unfamiliar test odours and 25 unfamiliar distractors combined. In Phase 2, after modification, all odours in SS-Sg and Scentsor were correctly identified by ≥75% of controls. In Phase 3, normative data (age 21-83 years) was obtained. Both tests had good test-retest reliability (Pearson's correlation coefficient of 0.88 with<0.001 for SS-Sg; and at 0.90 with<0.001 for Scentsor). Both tests differentiated among normosmia, hyposmia and anosmia (SS-Sg scores: 12.6 [±2.4] versus [vs] 9.8 (±3.2) vs 6.0 [±2.3] respectively,<0.001; Scentsor scores: 14.3 [±1.8] vs 11.3 [±2.8] vs 5.8 [±3.4] respectively,<0.001).</p><p><strong>Conclusion: </strong>SS-Sg and Scentsor have been validated to assess olfaction in Singapore.</p>","PeriodicalId":502093,"journal":{"name":"Annals of the Academy of Medicine, Singapore","volume":"54 6","pages":"329-339"},"PeriodicalIF":2.0000,"publicationDate":"2025-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of the Academy of Medicine, Singapore","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47102/annals-acadmedsg.2024364","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Odour recognition is influenced by culture. Odour identification tests need to be adapted to a population to accurately assess olfactory function. This study's objectives were to validate the Singapore version of the Sniffin' Sticks (SS-Sg) and a locally-developed odour recognition test (Scentsor) for Singapore.
Method: This prospective study was performed in 3 otolaryngology outpatient clinics in 3 phases (1 May to 15 November 2024). Phase 1 was a survey evaluation of 93 odour descriptors to identify familiar odour descriptors to be used in the tests (n=414); Phase 2 evaluated and finalised SS-Sg and Scentsor to ensure test odours were recognised by ≥75% of healthy controls (n=130); and Phase 3 validated both tests on healthy controls (n=473) to obtain normative data, to determine test-retest reliability (n=50), and to assess the ability to distinguish patients with olfactory loss (n=67).
Results: In Phase 1, the unmodified SS blue and purple sets had 15/32 (46.9%) unfamiliar test odours and 25 unfamiliar distractors combined. In Phase 2, after modification, all odours in SS-Sg and Scentsor were correctly identified by ≥75% of controls. In Phase 3, normative data (age 21-83 years) was obtained. Both tests had good test-retest reliability (Pearson's correlation coefficient of 0.88 with<0.001 for SS-Sg; and at 0.90 with<0.001 for Scentsor). Both tests differentiated among normosmia, hyposmia and anosmia (SS-Sg scores: 12.6 [±2.4] versus [vs] 9.8 (±3.2) vs 6.0 [±2.3] respectively,<0.001; Scentsor scores: 14.3 [±1.8] vs 11.3 [±2.8] vs 5.8 [±3.4] respectively,<0.001).
Conclusion: SS-Sg and Scentsor have been validated to assess olfaction in Singapore.