A study of the clinical usefulness of the eMEMO®

IF 2.2 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Hinako Nakayama, Nobuhisa Watanabe, Misa Tsukamoto, Miyu Mori, Eri Nakakubo, Shogo Watanabe, Manabu Taniguchi MD, PhD
{"title":"A study of the clinical usefulness of the eMEMO®","authors":"Hinako Nakayama,&nbsp;Nobuhisa Watanabe,&nbsp;Misa Tsukamoto,&nbsp;Miyu Mori,&nbsp;Eri Nakakubo,&nbsp;Shogo Watanabe,&nbsp;Manabu Taniguchi MD, PhD","doi":"10.1002/joa3.70137","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Taking advantage of the characteristics of the novel compact external loop recorder (ELR; eMEMO®), which is waterproof and has an automatic arrhythmia detection and monitoring function for up to 14 days, we investigated the usefulness of ELR measurement, especially during bathing.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>We included 294 patients (102 males and 192 females) who presented with palpitations as their main complaint from April 2021 to September 2022, with a mean age of 57.0 ± 17.4 years. The average wearing period of the ELR was 4.5 ± 0.9 days.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>ELR for longer than 24 h led to the first arrhythmia detection in 170 (21.3%) of the 799 cases of all detected arrhythmias, including 11 with premature atrial contraction, 50 with premature ventricular contraction, 8 with atrial fibrillation, 32 with supraventricular tachycardia, and 21 with sick sinus syndrome. They had low noise contamination during measurement. Arrhythmic events during bathing were observed in 52 patients, effectively detecting arrhythmia during bathing, which was difficult with the usual 24-h Holter electrocardiography (ECG). In addition, the itching and rash of the skin at the electrode attachment over a period of up to 5 days were very mild, indicating the comfort of the waterproof patch-type electrode.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The patch-type ELR (eMEMO®) with waterproof design is capable of continuous recording regardless of restrictions such as bathing or exercise and is useful for detecting stable arrhythmias in patients with palpitations.</p>\n </section>\n </div>","PeriodicalId":15174,"journal":{"name":"Journal of Arrhythmia","volume":"41 4","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2025-07-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/joa3.70137","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Arrhythmia","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/joa3.70137","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Taking advantage of the characteristics of the novel compact external loop recorder (ELR; eMEMO®), which is waterproof and has an automatic arrhythmia detection and monitoring function for up to 14 days, we investigated the usefulness of ELR measurement, especially during bathing.

Methods

We included 294 patients (102 males and 192 females) who presented with palpitations as their main complaint from April 2021 to September 2022, with a mean age of 57.0 ± 17.4 years. The average wearing period of the ELR was 4.5 ± 0.9 days.

Results

ELR for longer than 24 h led to the first arrhythmia detection in 170 (21.3%) of the 799 cases of all detected arrhythmias, including 11 with premature atrial contraction, 50 with premature ventricular contraction, 8 with atrial fibrillation, 32 with supraventricular tachycardia, and 21 with sick sinus syndrome. They had low noise contamination during measurement. Arrhythmic events during bathing were observed in 52 patients, effectively detecting arrhythmia during bathing, which was difficult with the usual 24-h Holter electrocardiography (ECG). In addition, the itching and rash of the skin at the electrode attachment over a period of up to 5 days were very mild, indicating the comfort of the waterproof patch-type electrode.

Conclusions

The patch-type ELR (eMEMO®) with waterproof design is capable of continuous recording regardless of restrictions such as bathing or exercise and is useful for detecting stable arrhythmias in patients with palpitations.

Abstract Image

eMEMO®的临床应用研究
利用新型紧凑型外环路记录仪(ELR)的特点;eMEMO®),防水并具有长达14天的心律失常自动检测和监测功能,我们研究了ELR测量的有用性,特别是在洗澡期间。方法纳入2021年4月至2022年9月以心悸为主诉的患者294例(男102例,女192例),平均年龄57.0±17.4岁。ELR平均佩戴时间为4.5±0.9天。结果在799例心律失常中,ELR≥24 h首次检出心律失常170例(21.3%),其中房性早搏11例,室性早搏50例,房颤8例,室上性心动过速32例,病态窦性综合征21例。在测量过程中,它们的噪声污染很低。在52例患者中观察到洗澡时的心律失常事件,有效地检测到洗澡时的心律失常,这是常规24小时动态心电图(ECG)难以检测到的。此外,在长达5天的时间内,电极附着处皮肤的瘙痒和皮疹非常轻微,表明防水贴片式电极的舒适性。结论采用防水设计的贴片式ELR (eMEMO®)可在不受洗澡或运动等限制的情况下进行连续记录,可用于心悸患者的稳定型心律失常检测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Arrhythmia
Journal of Arrhythmia CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.90
自引率
10.00%
发文量
127
审稿时长
45 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信