Promising short-term results after anatomical total shoulder arthroplasty for glenohumeral osteoarthritis with a novel stemless humeral implant in combination with a pegged all-polyethylene bone ingrowth glenoid component.
Spiros Tsamassiotis, Tomas Smith, Karen Rychlik, Roman F Karkosch, Hauke Horstmann, Gunnar Jensen
{"title":"Promising short-term results after anatomical total shoulder arthroplasty for glenohumeral osteoarthritis with a novel stemless humeral implant in combination with a pegged all-polyethylene bone ingrowth glenoid component.","authors":"Spiros Tsamassiotis, Tomas Smith, Karen Rychlik, Roman F Karkosch, Hauke Horstmann, Gunnar Jensen","doi":"10.1007/s00590-025-04405-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Stemless anatomical shoulder arthroplasty offers numerous potential advantages over stemmed systems. The aim of this prospective study was to evaluate the clinical and radiological 2-year results of a novel metaphyseal anchored stemless shoulder system (Global Icon™ Stemless Shoulder System, DePuy Synthes, Warsaw, IN, USA).</p><p><strong>Methods: </strong>Thirty patients with primary osteoarthritis, 14 males and 6 females, were prospectively included in the study. Two-year follow-up data were analyzed for 20 patients. The average age and BMI were 63.4 years and 27.6 kg/m2. The adjusted Constant-Murley Score (aCS), Oxford Shoulder Score (OSS), and EQ-5D-5L were used as primary endpoints to reflect postoperative clinical improvement. Postoperative radiographs in two planes were analyzed for implant loosening and migration.</p><p><strong>Results: </strong>There was an overall clinical improvement 2 years postoperatively. The aCS increased from 58.3 ± 17.7 to 113.7 ± 15.6 points (p < 0.0001). The OSS score improved from 25.5 ± 6.1 to 43.9 ± 6.1 points (p < 0.0001). The EQ-5D-5L value score increased on average from 0.7 ± 0.2 to 0.9 ± 0.1 (p = 0.0004). There was no implant loosening or migration. No revisions were required.</p><p><strong>Conclusion: </strong>In summary, the examined prosthesis system achieved very good clinical and radiographic results 2 years postoperatively without implant failure. Shoulder function and quality of life improved significantly. These results are encouraging for prostheses with bone-preserving designs which rely on peripheral humeral fixation, though more long-term results are needed.</p><p><strong>Level of evidence: </strong>Level IV; Case Series; Treatment Study.</p>","PeriodicalId":50484,"journal":{"name":"European Journal of Orthopaedic Surgery and Traumatology","volume":"35 1","pages":"291"},"PeriodicalIF":1.5000,"publicationDate":"2025-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12227341/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Orthopaedic Surgery and Traumatology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s00590-025-04405-2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: Stemless anatomical shoulder arthroplasty offers numerous potential advantages over stemmed systems. The aim of this prospective study was to evaluate the clinical and radiological 2-year results of a novel metaphyseal anchored stemless shoulder system (Global Icon™ Stemless Shoulder System, DePuy Synthes, Warsaw, IN, USA).
Methods: Thirty patients with primary osteoarthritis, 14 males and 6 females, were prospectively included in the study. Two-year follow-up data were analyzed for 20 patients. The average age and BMI were 63.4 years and 27.6 kg/m2. The adjusted Constant-Murley Score (aCS), Oxford Shoulder Score (OSS), and EQ-5D-5L were used as primary endpoints to reflect postoperative clinical improvement. Postoperative radiographs in two planes were analyzed for implant loosening and migration.
Results: There was an overall clinical improvement 2 years postoperatively. The aCS increased from 58.3 ± 17.7 to 113.7 ± 15.6 points (p < 0.0001). The OSS score improved from 25.5 ± 6.1 to 43.9 ± 6.1 points (p < 0.0001). The EQ-5D-5L value score increased on average from 0.7 ± 0.2 to 0.9 ± 0.1 (p = 0.0004). There was no implant loosening or migration. No revisions were required.
Conclusion: In summary, the examined prosthesis system achieved very good clinical and radiographic results 2 years postoperatively without implant failure. Shoulder function and quality of life improved significantly. These results are encouraging for prostheses with bone-preserving designs which rely on peripheral humeral fixation, though more long-term results are needed.
Level of evidence: Level IV; Case Series; Treatment Study.
期刊介绍:
The European Journal of Orthopaedic Surgery and Traumatology (EJOST) aims to publish high quality Orthopedic scientific work. The objective of our journal is to disseminate meaningful, impactful, clinically relevant work from each and every region of the world, that has the potential to change and or inform clinical practice.