Promising short-term results after anatomical total shoulder arthroplasty for glenohumeral osteoarthritis with a novel stemless humeral implant in combination with a pegged all-polyethylene bone ingrowth glenoid component.

IF 1.5 Q3 ORTHOPEDICS
Spiros Tsamassiotis, Tomas Smith, Karen Rychlik, Roman F Karkosch, Hauke Horstmann, Gunnar Jensen
{"title":"Promising short-term results after anatomical total shoulder arthroplasty for glenohumeral osteoarthritis with a novel stemless humeral implant in combination with a pegged all-polyethylene bone ingrowth glenoid component.","authors":"Spiros Tsamassiotis, Tomas Smith, Karen Rychlik, Roman F Karkosch, Hauke Horstmann, Gunnar Jensen","doi":"10.1007/s00590-025-04405-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Stemless anatomical shoulder arthroplasty offers numerous potential advantages over stemmed systems. The aim of this prospective study was to evaluate the clinical and radiological 2-year results of a novel metaphyseal anchored stemless shoulder system (Global Icon™ Stemless Shoulder System, DePuy Synthes, Warsaw, IN, USA).</p><p><strong>Methods: </strong>Thirty patients with primary osteoarthritis, 14 males and 6 females, were prospectively included in the study. Two-year follow-up data were analyzed for 20 patients. The average age and BMI were 63.4 years and 27.6 kg/m2. The adjusted Constant-Murley Score (aCS), Oxford Shoulder Score (OSS), and EQ-5D-5L were used as primary endpoints to reflect postoperative clinical improvement. Postoperative radiographs in two planes were analyzed for implant loosening and migration.</p><p><strong>Results: </strong>There was an overall clinical improvement 2 years postoperatively. The aCS increased from 58.3 ± 17.7 to 113.7 ± 15.6 points (p < 0.0001). The OSS score improved from 25.5 ± 6.1 to 43.9 ± 6.1 points (p < 0.0001). The EQ-5D-5L value score increased on average from 0.7 ± 0.2 to 0.9 ± 0.1 (p = 0.0004). There was no implant loosening or migration. No revisions were required.</p><p><strong>Conclusion: </strong>In summary, the examined prosthesis system achieved very good clinical and radiographic results 2 years postoperatively without implant failure. Shoulder function and quality of life improved significantly. These results are encouraging for prostheses with bone-preserving designs which rely on peripheral humeral fixation, though more long-term results are needed.</p><p><strong>Level of evidence: </strong>Level IV; Case Series; Treatment Study.</p>","PeriodicalId":50484,"journal":{"name":"European Journal of Orthopaedic Surgery and Traumatology","volume":"35 1","pages":"291"},"PeriodicalIF":1.5000,"publicationDate":"2025-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12227341/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Orthopaedic Surgery and Traumatology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s00590-025-04405-2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Stemless anatomical shoulder arthroplasty offers numerous potential advantages over stemmed systems. The aim of this prospective study was to evaluate the clinical and radiological 2-year results of a novel metaphyseal anchored stemless shoulder system (Global Icon™ Stemless Shoulder System, DePuy Synthes, Warsaw, IN, USA).

Methods: Thirty patients with primary osteoarthritis, 14 males and 6 females, were prospectively included in the study. Two-year follow-up data were analyzed for 20 patients. The average age and BMI were 63.4 years and 27.6 kg/m2. The adjusted Constant-Murley Score (aCS), Oxford Shoulder Score (OSS), and EQ-5D-5L were used as primary endpoints to reflect postoperative clinical improvement. Postoperative radiographs in two planes were analyzed for implant loosening and migration.

Results: There was an overall clinical improvement 2 years postoperatively. The aCS increased from 58.3 ± 17.7 to 113.7 ± 15.6 points (p < 0.0001). The OSS score improved from 25.5 ± 6.1 to 43.9 ± 6.1 points (p < 0.0001). The EQ-5D-5L value score increased on average from 0.7 ± 0.2 to 0.9 ± 0.1 (p = 0.0004). There was no implant loosening or migration. No revisions were required.

Conclusion: In summary, the examined prosthesis system achieved very good clinical and radiographic results 2 years postoperatively without implant failure. Shoulder function and quality of life improved significantly. These results are encouraging for prostheses with bone-preserving designs which rely on peripheral humeral fixation, though more long-term results are needed.

Level of evidence: Level IV; Case Series; Treatment Study.

解剖全肩关节置换术治疗肩关节骨性关节炎,采用新型无柄肱骨假体联合固定式全聚乙烯骨向内生长肩关节假体,短期效果良好。
目的:无柄解剖肩关节置换术提供了许多潜在的优势比干系统。这项前瞻性研究的目的是评估一种新型干骺端锚定无茎肩系统(Global Icon™无茎肩系统,DePuy Synthes, Warsaw, IN, USA) 2年的临床和放射学结果。方法:30例原发性骨关节炎患者,男14例,女6例。对20例患者的2年随访数据进行分析。平均年龄为63.4岁,BMI为27.6 kg/m2。调整后的Constant-Murley评分(aCS)、Oxford肩部评分(OSS)和EQ-5D-5L作为反映术后临床改善的主要终点。术后两平面x线片分析假体松动和移位情况。结果:术后2年临床总体改善。aCS从58.3±17.7分增加到113.7±15.6分(p)。结论:术后2年,所检查的假体系统取得了很好的临床和影像学结果,无假体失效。肩部功能和生活质量明显改善。尽管还需要更多的长期结果,但这些结果对于依靠肱骨外周固定的保骨设计的假体来说是令人鼓舞的。证据等级:四级;系列;治疗研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.00
自引率
5.90%
发文量
265
审稿时长
3-8 weeks
期刊介绍: The European Journal of Orthopaedic Surgery and Traumatology (EJOST) aims to publish high quality Orthopedic scientific work. The objective of our journal is to disseminate meaningful, impactful, clinically relevant work from each and every region of the world, that has the potential to change and or inform clinical practice.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信