[Fast determination of per- and polyfluoroalkyl substances in human serum by cold-induced phase separation coupled with liquid chromatography-tandem mass spectrometry].

Jian-di Wang, Yi-Wei Wang, Jia-Xin Wu, Zhi-Xiong Shi
{"title":"[Fast determination of per- and polyfluoroalkyl substances in human serum by cold-induced phase separation coupled with liquid chromatography-tandem mass spectrometry].","authors":"Jian-di Wang, Yi-Wei Wang, Jia-Xin Wu, Zhi-Xiong Shi","doi":"10.3724/SP.J.1123.2024.11028","DOIUrl":null,"url":null,"abstract":"<p><p>Per- and polyfluoroalkyl substances (PFASs) are a large group of synthetic chemicals that have been widely used in various industrial and commercial products owing to their unique physicochemical properties. However, accumulating evidence suggests that PFASs are persistent, transmissive over long distances, bioaccumulative, and toxic; consequently, their adverse effects on ecosystems and humans is of widespread concern. Serum is the most commonly used human matrix for assessing internal exposure to environmental pollutants, and several analytical methods have been developed to measure PFASs in sera. Current methods are generally fast, convenient, and robust; however, their pretreatment steps require large amounts of organic solvents and materials, such as solid-phase extraction cartridges and/or sorbents. In this study, a novel and low-cost analytical method based on cold-induced phase separation (CIPS) strategy was developed for the simultaneous determination of 31 legacy and emerging PFASs in serum. The core mechanism and distinctive feature of CIPS involves cooling an acetonitrile-water (ACN-water) mixture at a low temperature to produce two clear-cut layers: one with a high ACN proportion (the ACN layer) and an aqueous layer (water layer). Certain chemicals are significantly enriched in the ACN layer during cooling; at the same time, impurities, especially water-soluble impurities, remain in the aqueous layer. CIPS only requires the temperature to be varied, and no external impurities are introduced during pretreatment, which dramatically reduces material costs and avoids new impurities from intervening. Our method involves the following procedure: serum was drawn accurately (0.2 mL) into a 1.5 mL Eppendorf (EP) tube, 2 ng of each isotopically labeled internal standard was added, the mixture is vortexed, and 350 µL of ACN was added, followed by vortexing and ultrasonic extraction. Subsequently, 450 µL of water is added to adjust the volume proportion of ACN to 35% (the volume percentage of ACN in the total solution). The protein at the bottom of the tube was collected following centrifugation at 15 000 r/min for 10 min, and the supernatant was transferred to a 1 mL syringe. The syringe was frozen in a -20 ℃ refrigerator for 1 h to obtain the two layers, after which the upper layer (approximately 80-100 μL) containing ACN and the target compounds was finally transferred to a glass vial for instrumental analysis. Liquid chromatography coupled with triple quadrupole mass spectrometry augmented with electrospray ionization (LC-ESI-MS/MS) was used to quantify the PFASs. The analytes were separated using a C18 column, with methanol and 2 mmol/L of ammonium formate-H<sub>2</sub>O used as mobile phases. Linearities, limits of detection (LODs) and, limits of quantification (LOQs), recoveries, precisions, and matrix effects were determined under the optimal conditions. The LODs and LOQs of PFASs in serum were 0.01-25 and 0.03-83 pg/mL, respectively. Under two spiked levels, namely 5 ng/mL and 25 ng/mL, average recoveries ranged between 60.5% and 129.6%, with relative standard deviations (RSDs) of less than 22.8%. Under 5 pg/mL as LOD spiked level, average recoveries ranged between 61.6% and 199.1%,with RSDs<29.4%. While matrix-effect testing revealed slightly enhanced signals, the use of isotopically labeled internal standards compensated for these effects. Real samples were subsequently analyzed, with 50 human serum samples collected in first trimester of pregnancy women living in the Shunyi District, Beijing. Nine PFASs exhibited high detection frequencies (>80%), which suggests that PFASs are ubiquitous in the population. The median and mean levels of Σ<sub>31</sub>PFASs (sum of 31 PFASs) in serum were 21.8 and 22.9 ng/mL, respectively, and the range was 0.456-73.9 ng/mL. Both legacy and emerging PFASs were detected at high frequencies and contamination levels, which suggests that they are widely used. In summary, the method developed in this study is fast, sensitive, and solvent- and material-efficient; it is also very linear and highly accurate, and exhibits satisfactory extraction recovery and enrichment factors; hence, it is suitable for surveying large populations as well as for use in environmental epidemiology.</p>","PeriodicalId":101336,"journal":{"name":"Se pu = Chinese journal of chromatography","volume":"43 7","pages":"756-766"},"PeriodicalIF":0.0000,"publicationDate":"2025-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12231447/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Se pu = Chinese journal of chromatography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3724/SP.J.1123.2024.11028","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Per- and polyfluoroalkyl substances (PFASs) are a large group of synthetic chemicals that have been widely used in various industrial and commercial products owing to their unique physicochemical properties. However, accumulating evidence suggests that PFASs are persistent, transmissive over long distances, bioaccumulative, and toxic; consequently, their adverse effects on ecosystems and humans is of widespread concern. Serum is the most commonly used human matrix for assessing internal exposure to environmental pollutants, and several analytical methods have been developed to measure PFASs in sera. Current methods are generally fast, convenient, and robust; however, their pretreatment steps require large amounts of organic solvents and materials, such as solid-phase extraction cartridges and/or sorbents. In this study, a novel and low-cost analytical method based on cold-induced phase separation (CIPS) strategy was developed for the simultaneous determination of 31 legacy and emerging PFASs in serum. The core mechanism and distinctive feature of CIPS involves cooling an acetonitrile-water (ACN-water) mixture at a low temperature to produce two clear-cut layers: one with a high ACN proportion (the ACN layer) and an aqueous layer (water layer). Certain chemicals are significantly enriched in the ACN layer during cooling; at the same time, impurities, especially water-soluble impurities, remain in the aqueous layer. CIPS only requires the temperature to be varied, and no external impurities are introduced during pretreatment, which dramatically reduces material costs and avoids new impurities from intervening. Our method involves the following procedure: serum was drawn accurately (0.2 mL) into a 1.5 mL Eppendorf (EP) tube, 2 ng of each isotopically labeled internal standard was added, the mixture is vortexed, and 350 µL of ACN was added, followed by vortexing and ultrasonic extraction. Subsequently, 450 µL of water is added to adjust the volume proportion of ACN to 35% (the volume percentage of ACN in the total solution). The protein at the bottom of the tube was collected following centrifugation at 15 000 r/min for 10 min, and the supernatant was transferred to a 1 mL syringe. The syringe was frozen in a -20 ℃ refrigerator for 1 h to obtain the two layers, after which the upper layer (approximately 80-100 μL) containing ACN and the target compounds was finally transferred to a glass vial for instrumental analysis. Liquid chromatography coupled with triple quadrupole mass spectrometry augmented with electrospray ionization (LC-ESI-MS/MS) was used to quantify the PFASs. The analytes were separated using a C18 column, with methanol and 2 mmol/L of ammonium formate-H2O used as mobile phases. Linearities, limits of detection (LODs) and, limits of quantification (LOQs), recoveries, precisions, and matrix effects were determined under the optimal conditions. The LODs and LOQs of PFASs in serum were 0.01-25 and 0.03-83 pg/mL, respectively. Under two spiked levels, namely 5 ng/mL and 25 ng/mL, average recoveries ranged between 60.5% and 129.6%, with relative standard deviations (RSDs) of less than 22.8%. Under 5 pg/mL as LOD spiked level, average recoveries ranged between 61.6% and 199.1%,with RSDs<29.4%. While matrix-effect testing revealed slightly enhanced signals, the use of isotopically labeled internal standards compensated for these effects. Real samples were subsequently analyzed, with 50 human serum samples collected in first trimester of pregnancy women living in the Shunyi District, Beijing. Nine PFASs exhibited high detection frequencies (>80%), which suggests that PFASs are ubiquitous in the population. The median and mean levels of Σ31PFASs (sum of 31 PFASs) in serum were 21.8 and 22.9 ng/mL, respectively, and the range was 0.456-73.9 ng/mL. Both legacy and emerging PFASs were detected at high frequencies and contamination levels, which suggests that they are widely used. In summary, the method developed in this study is fast, sensitive, and solvent- and material-efficient; it is also very linear and highly accurate, and exhibits satisfactory extraction recovery and enrichment factors; hence, it is suitable for surveying large populations as well as for use in environmental epidemiology.

Abstract Image

Abstract Image

[冷诱导相分离-液相色谱-串联质谱法快速测定人血清中的单氟烷基和多氟烷基物质]。
全氟烷基和多氟烷基物质(PFASs)是一类合成化学品,由于其独特的物理化学性质,已广泛应用于各种工业和商业产品。然而,越来越多的证据表明,全氟辛烷磺酸具有持久性、远距离传播性、生物蓄积性和毒性;因此,它们对生态系统和人类的不利影响受到广泛关注。血清是评估体内环境污染物暴露的最常用的人体基质,并且已经开发了几种分析方法来测量血清中的PFASs。目前的方法通常是快速、方便和可靠的;然而,它们的预处理步骤需要大量的有机溶剂和材料,如固相萃取盒和/或吸附剂。本研究建立了一种基于冷诱导相分离(CIPS)策略的新型低成本分析方法,用于同时测定血清中31种遗留和新出现的PFASs。CIPS的核心机制和独特特征是在低温下冷却乙腈-水(ACN-水)混合物,产生两个清晰的层:一个是高ACN比例的ACN层(ACN层)和一个水层(水层)。某些化学物质在冷却过程中在ACN层中显著富集,同时杂质,特别是水溶性杂质留在水层中。CIPS只需要改变温度,预处理过程中不引入外部杂质,大大降低了材料成本,避免了新杂质的介入。我们的方法包括以下步骤:将血清(0.2 mL)准确抽取到1.5 mL埃彭多夫(EP)管中,加入每种同位素标记的内标物2 ng,搅拌,加入ACN 350µL,进行涡流和超声提取。随后,加入450µL的水,将ACN的体积比例调整到35% (ACN在总溶液中的体积百分比)。在15 000 r/min离心10 min后收集管底蛋白,将上清转移到1 mL注射器中。注射器在-20℃的冰箱中冷冻1 h,得到两层,最后将含有ACN和目标化合物的上层(约80-100 μL)转移到玻璃小瓶中进行仪器分析。采用液相色谱-三重四极杆质谱-电喷雾电离法(LC-ESI-MS/MS)对PFASs进行定量分析。色谱柱为C18,流动相为甲醇和2 mmol/L甲酸铵- h2o。在最佳条件下测定了线性、检出限、定量限、回收率、精密度和基质效应。血清中PFASs的lod为0.01 ~ 25 pg/mL, loq为0.03 ~ 83 pg/mL。在5 ng/mL和25 ng/mL加标水平下,平均加标回收率为60.5% ~ 129.6%,相对标准偏差(rsd)小于22.8%。在LOD加标水平为5 pg/mL时,平均加标回收率为61.6% ~ 199.1%,rsds为80%,表明PFASs在人群中普遍存在。血清中Σ31PFASs(31种PFASs的总和)的中位数和平均值分别为21.8和22.9 ng/mL,范围为0.456 ~ 73.9 ng/mL。遗留的和新出现的PFASs都在高频率和污染水平下被检测到,这表明它们被广泛使用。综上所述,本方法具有快速、灵敏、溶剂和材料效率高、线性性好、准确度高、提取回收率和富集系数高的特点,适用于大规模人群调查和环境流行病学研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信