Kai Zhao , Hui Xu , Jie Zhang , Xiao Lin , Liming Sheng , Yujin Xu , Binbing Wang , Qing Hou , Xue Bai
{"title":"Study on the stability of lung cancer radiotherapy dosiomic features under respiratory motion","authors":"Kai Zhao , Hui Xu , Jie Zhang , Xiao Lin , Liming Sheng , Yujin Xu , Binbing Wang , Qing Hou , Xue Bai","doi":"10.1016/j.ejmp.2025.105040","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><div>To assess the stability of dosiomic features in response to dose distribution variations caused by respiratory motion.</div></div><div><h3>Methods and Materials</h3><div>A total of 24 lung cancer patients who underwent 4DCT scanning and radiotherapy were included. For each patient, a 3D dose matrix and three 4D dose matrices generated using three distinct methods were calculated. Dosiomic features were extracted from dose distributions for four regions of interest: the gross tumor volume (GTV), the planning target volume (PTV), the heart, and the lung. The stability of each dosiomic feature was evaluated using the coefficient of variation (CV), while reproducibility was assessed using the intraclass correlation coefficient (ICC). The differences between 3D and 4D dose features were determined using the normalized difference (ND).</div></div><div><h3>Results</h3><div>5.0% of dosiomic features had a CV greater than or equal to 20%. The CVs were highest in the GTV region and lowest in the lung region. Additionally, 0.27% of features had an ICC less than 0.5, while 92.74% had an ICC greater than 0.9. 16.48% of features had an absolute value of the ND greater than 0.4.</div></div><div><h3>Conclusions</h3><div>The stability of certain dosiomic features is strongly influenced by respiratory motion in radiotherapy. To ensure result reproducibility, dosiomic studies should fully consider the impact of respiratory motion during dose calculation or excluding unstable features to enhance model stability.</div></div>","PeriodicalId":56092,"journal":{"name":"Physica Medica-European Journal of Medical Physics","volume":"136 ","pages":"Article 105040"},"PeriodicalIF":2.7000,"publicationDate":"2025-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physica Medica-European Journal of Medical Physics","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1120179725001504","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose
To assess the stability of dosiomic features in response to dose distribution variations caused by respiratory motion.
Methods and Materials
A total of 24 lung cancer patients who underwent 4DCT scanning and radiotherapy were included. For each patient, a 3D dose matrix and three 4D dose matrices generated using three distinct methods were calculated. Dosiomic features were extracted from dose distributions for four regions of interest: the gross tumor volume (GTV), the planning target volume (PTV), the heart, and the lung. The stability of each dosiomic feature was evaluated using the coefficient of variation (CV), while reproducibility was assessed using the intraclass correlation coefficient (ICC). The differences between 3D and 4D dose features were determined using the normalized difference (ND).
Results
5.0% of dosiomic features had a CV greater than or equal to 20%. The CVs were highest in the GTV region and lowest in the lung region. Additionally, 0.27% of features had an ICC less than 0.5, while 92.74% had an ICC greater than 0.9. 16.48% of features had an absolute value of the ND greater than 0.4.
Conclusions
The stability of certain dosiomic features is strongly influenced by respiratory motion in radiotherapy. To ensure result reproducibility, dosiomic studies should fully consider the impact of respiratory motion during dose calculation or excluding unstable features to enhance model stability.
期刊介绍:
Physica Medica, European Journal of Medical Physics, publishing with Elsevier from 2007, provides an international forum for research and reviews on the following main topics:
Medical Imaging
Radiation Therapy
Radiation Protection
Measuring Systems and Signal Processing
Education and training in Medical Physics
Professional issues in Medical Physics.