{"title":"[Determination of Acetate Content in Hemodialysis Solutions and Dialysis Concentrates by HPLC].","authors":"Huadong Wang, Yue Wang, Dong Liu, Xianghui Liu","doi":"10.12455/j.issn.1671-7104.240718","DOIUrl":null,"url":null,"abstract":"<p><p>This study establishes a high-performance liquid chromatography (HPLC) method for the determination of acetate content in hemodialysis solutions and dialysis concentrates. In this study, Synergi Polar-RP column is utilized. Phosphate buffered saline (50 mmol/L, pH=2.5) is used as a mobile phase. The flow rate is 1.0 mL/min. The wavelength of detection is 212 nm. Results show that the linear relationship of acetate is good in the range of 0.1~20 mmol/L, <i>r</i> =0.999 9 and the spike recoveries are from 98.9%~99.5%, RSD<0.5% ( <i>n</i>=3). This method can easily and accurately determine the acetate content in hemodialysis solutions and dialysis concentrates, and can be applied to quality control in the production and use of such products.</p>","PeriodicalId":52535,"journal":{"name":"中国医疗器械杂志","volume":"49 3","pages":"350-354"},"PeriodicalIF":0.0000,"publicationDate":"2025-05-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国医疗器械杂志","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.12455/j.issn.1671-7104.240718","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
This study establishes a high-performance liquid chromatography (HPLC) method for the determination of acetate content in hemodialysis solutions and dialysis concentrates. In this study, Synergi Polar-RP column is utilized. Phosphate buffered saline (50 mmol/L, pH=2.5) is used as a mobile phase. The flow rate is 1.0 mL/min. The wavelength of detection is 212 nm. Results show that the linear relationship of acetate is good in the range of 0.1~20 mmol/L, r =0.999 9 and the spike recoveries are from 98.9%~99.5%, RSD<0.5% ( n=3). This method can easily and accurately determine the acetate content in hemodialysis solutions and dialysis concentrates, and can be applied to quality control in the production and use of such products.
期刊介绍:
Chinese Journal of Medical Instrumentation mainly reports on the development, progress, research and development, production, clinical application, management, and maintenance of medical devices and biomedical engineering. Its aim is to promote the exchange of information on medical devices and biomedical engineering in China and turn the journal into a high-quality academic journal that leads academic directions and advocates academic debates.