A comparison between two image reconstructions on the measures of prostate-specific membrane antigen-positive tumor volume in 18 F-PSMA-JK-7-PET/computed tomography.

IF 1.3 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Nuclear Medicine Communications Pub Date : 2025-10-01 Epub Date: 2025-06-24 DOI:10.1097/MNM.0000000000002021
Dominic Ufton, Jan Heilinger, Katrin S Roth, Matthias Schmidt, Alexander Drzezga, Carsten Kobe
{"title":"A comparison between two image reconstructions on the measures of prostate-specific membrane antigen-positive tumor volume in 18 F-PSMA-JK-7-PET/computed tomography.","authors":"Dominic Ufton, Jan Heilinger, Katrin S Roth, Matthias Schmidt, Alexander Drzezga, Carsten Kobe","doi":"10.1097/MNM.0000000000002021","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Tumor volume in prostate-specific membrane antigen (PSMA-TV)-PET/computed tomography (CT) has shown an emerging impact for prognosis and response evaluation in patients with prostate cancer. We evaluated the robustness of different PSMA-TV delineation methods.</p><p><strong>Materials and methods: </strong>A total of 40 18 F-JK-7-PSMA-PET/CT performed on the same scanner were analyzed. PSMA-TV measurements were performed using a standardized uptake value of 4.0 as a fixed threshold (T1), 41% of the single hottest voxel as an adaptive threshold (T2), and a liver-specific threshold (T3) for delineation in two reconstruction methods [four iterations and 12 subsets (R1) and three iterations and 21 subsets while applying a point spread function and a time-of-flight algorithm (R2)]. Differences between the segmentation thresholds in R1 and R2 were gathered and tested for statistical significance.</p><p><strong>Results: </strong>PSMA-TV differed significantly between R1Tx and R2Tx for individual segmentation thresholds, with PSMA-TV in R2 being significantly smaller than in R1 using the same segmentation method. Comparing the differences in PSMA-TV between R1 and R2 reconstruction between the three separate segmentation thresholds showed significantly larger absolute volume differences for T2 compared with T3 and significantly larger relative volume differences for T2 compared with T1 and T3.</p><p><strong>Conclusion: </strong>Reconstruction settings greatly influence the measurement of PSMA-TV, regardless of the segmentation threshold chosen; however, our results indicate that the fixed thresholds (T1 and T3) are less susceptible to reconstruction-induced volumetry effects than a relative threshold.</p>","PeriodicalId":19708,"journal":{"name":"Nuclear Medicine Communications","volume":" ","pages":"967-971"},"PeriodicalIF":1.3000,"publicationDate":"2025-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Medicine Communications","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MNM.0000000000002021","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/6/24 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Tumor volume in prostate-specific membrane antigen (PSMA-TV)-PET/computed tomography (CT) has shown an emerging impact for prognosis and response evaluation in patients with prostate cancer. We evaluated the robustness of different PSMA-TV delineation methods.

Materials and methods: A total of 40 18 F-JK-7-PSMA-PET/CT performed on the same scanner were analyzed. PSMA-TV measurements were performed using a standardized uptake value of 4.0 as a fixed threshold (T1), 41% of the single hottest voxel as an adaptive threshold (T2), and a liver-specific threshold (T3) for delineation in two reconstruction methods [four iterations and 12 subsets (R1) and three iterations and 21 subsets while applying a point spread function and a time-of-flight algorithm (R2)]. Differences between the segmentation thresholds in R1 and R2 were gathered and tested for statistical significance.

Results: PSMA-TV differed significantly between R1Tx and R2Tx for individual segmentation thresholds, with PSMA-TV in R2 being significantly smaller than in R1 using the same segmentation method. Comparing the differences in PSMA-TV between R1 and R2 reconstruction between the three separate segmentation thresholds showed significantly larger absolute volume differences for T2 compared with T3 and significantly larger relative volume differences for T2 compared with T1 and T3.

Conclusion: Reconstruction settings greatly influence the measurement of PSMA-TV, regardless of the segmentation threshold chosen; however, our results indicate that the fixed thresholds (T1 and T3) are less susceptible to reconstruction-induced volumetry effects than a relative threshold.

两种图像重建在18F-PSMA-JK-7-PET/计算机断层扫描中测量前列腺特异性膜抗原阳性肿瘤体积的比较
目的:前列腺特异性膜抗原(PSMA-TV)-PET/计算机断层扫描(CT)显示出对前列腺癌患者预后和反应评估的新影响。我们评估了不同PSMA-TV描绘方法的稳健性。材料与方法:对同一台扫描仪上的40张18F-JK-7-PSMA-PET/CT进行分析。采用标准化摄取值4.0作为固定阈值(T1),单个最热体素的41%作为自适应阈值(T2),以及肝脏特异性阈值(T3)进行PSMA-TV测量,用于两种重建方法[4次迭代和12个子集(R1)和3次迭代和21个子集,同时应用点扩展函数和飞行时间算法(R2)]。收集R1和R2分割阈值的差异,检验有无统计学意义。结果:R1Tx和R2Tx的PSMA-TV在单个分割阈值上存在显著差异,在相同分割方法下,R2中的PSMA-TV明显小于R1。比较三个独立分割阈值之间R1和R2重构的PSMA-TV差异,T2的绝对体积差异明显大于T3, T2的相对体积差异明显大于T1和T3。结论:无论分割阈值的选择如何,重建设置对PSMA-TV的测量都有很大的影响;然而,我们的研究结果表明,固定阈值(T1和T3)比相对阈值更不容易受到重建诱导的体积效应的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.20
自引率
6.70%
发文量
212
审稿时长
3-8 weeks
期刊介绍: Nuclear Medicine Communications, the official journal of the British Nuclear Medicine Society, is a rapid communications journal covering nuclear medicine and molecular imaging with radionuclides, and the basic supporting sciences. As well as clinical research and commentary, manuscripts describing research on preclinical and basic sciences (radiochemistry, radiopharmacy, radiobiology, radiopharmacology, medical physics, computing and engineering, and technical and nursing professions involved in delivering nuclear medicine services) are welcomed, as the journal is intended to be of interest internationally to all members of the many medical and non-medical disciplines involved in nuclear medicine. In addition to papers reporting original studies, frankly written editorials and topical reviews are a regular feature of the journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信