Madhumathi Jayaprakasam, Joy Sarojini Michael, Parul Jain, Shaoli Basu, Kanchan Ajbani, Siva Kumar Shanmugam, Marilyn Mary Ninan, Hansraj Choudhary, Amita Jain, Ravindra Mohan Pandey, Nivedita Gupta
{"title":"Diagnostic accuracy of real-time PCR assay 'Quantiplus® MTB FAST' for detection of adult pulmonary tuberculosis (PTB): A multi-centric study.","authors":"Madhumathi Jayaprakasam, Joy Sarojini Michael, Parul Jain, Shaoli Basu, Kanchan Ajbani, Siva Kumar Shanmugam, Marilyn Mary Ninan, Hansraj Choudhary, Amita Jain, Ravindra Mohan Pandey, Nivedita Gupta","doi":"10.25259/IJMR_767_2025","DOIUrl":null,"url":null,"abstract":"<p><p>Background & objectives The global target set by the United Nations (UN) high-level meeting on Tuberculosis (TB) for coverage of rapid molecular tests is 100 per cent by 2027. Rapid, affordable molecular tests for early detection of TB are the need of the hour. This study aimed to evaluate the diagnostic accuracy of an open real-time PCR (RT-PCR) assay, Quantiplus®, with reference to Mycobacteria Growth Indicator Tube (MGIT) liquid culture. Methods We conducted a prospective multi-centric diagnostic accuracy study of Quantiplus® assay (version 2.0) at three sites in India for the detection of pulmonary TB in sputum with culture as the reference standard, compared with Xpert® MTB/RIF. A total of 657 adults (>18 yr) with presumptive TB were enrolled consecutively. The Quantiplus® assay uses an extraction-free, quick-lysis protocol and three gene targets for RT-PCR. Results Of the 644 samples analysed, 37 per cent were culture-positive and 32 per cent were smear-positive. The sensitivity and specificity of Quantiplus® assay with reference to MGIT culture were 86 per cent [95% confidence interval (CI): 81-90] and 96 per cent (95% CI: 94-98), respectively, at Ct ≤ 38. The positive and negative predictive values (PPV/NPV) were 93 per cent (95% CI: 89-96%) and 92 per cent (95% CI: 89-94%), respectively. Among the 73 smear-negative culture-positive specimens, the sensitivity and specificity were 61.6 per cent (95% CI: 50-73) and 97 per cent (95% CI: 92-98.6), respectively. The performance of Quantiplus® assay(v2.0) was comparable to Xpert MTB/RIF® (κ=0.83, SE=0.02) at Ct ≤38. Interpretation & conclusions The flexibility of the open RT-PCR assay to be used in any RT-PCR machine makes it a very low-cost (<2 US$) alternative to the expensive cartridge-based tests. This is the first report of validation of an open system RT-PCR assay for the detection of pulmonary TB.</p>","PeriodicalId":13349,"journal":{"name":"Indian Journal of Medical Research","volume":"161 4","pages":"346-353"},"PeriodicalIF":2.7000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12178193/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Medical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.25259/IJMR_767_2025","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"IMMUNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background & objectives The global target set by the United Nations (UN) high-level meeting on Tuberculosis (TB) for coverage of rapid molecular tests is 100 per cent by 2027. Rapid, affordable molecular tests for early detection of TB are the need of the hour. This study aimed to evaluate the diagnostic accuracy of an open real-time PCR (RT-PCR) assay, Quantiplus®, with reference to Mycobacteria Growth Indicator Tube (MGIT) liquid culture. Methods We conducted a prospective multi-centric diagnostic accuracy study of Quantiplus® assay (version 2.0) at three sites in India for the detection of pulmonary TB in sputum with culture as the reference standard, compared with Xpert® MTB/RIF. A total of 657 adults (>18 yr) with presumptive TB were enrolled consecutively. The Quantiplus® assay uses an extraction-free, quick-lysis protocol and three gene targets for RT-PCR. Results Of the 644 samples analysed, 37 per cent were culture-positive and 32 per cent were smear-positive. The sensitivity and specificity of Quantiplus® assay with reference to MGIT culture were 86 per cent [95% confidence interval (CI): 81-90] and 96 per cent (95% CI: 94-98), respectively, at Ct ≤ 38. The positive and negative predictive values (PPV/NPV) were 93 per cent (95% CI: 89-96%) and 92 per cent (95% CI: 89-94%), respectively. Among the 73 smear-negative culture-positive specimens, the sensitivity and specificity were 61.6 per cent (95% CI: 50-73) and 97 per cent (95% CI: 92-98.6), respectively. The performance of Quantiplus® assay(v2.0) was comparable to Xpert MTB/RIF® (κ=0.83, SE=0.02) at Ct ≤38. Interpretation & conclusions The flexibility of the open RT-PCR assay to be used in any RT-PCR machine makes it a very low-cost (<2 US$) alternative to the expensive cartridge-based tests. This is the first report of validation of an open system RT-PCR assay for the detection of pulmonary TB.
期刊介绍:
The Indian Journal of Medical Research (IJMR) [ISSN 0971-5916] is one of the oldest medical Journals not only in India, but probably in Asia, as it started in the year 1913. The Journal was started as a quarterly (4 issues/year) in 1913 and made bimonthly (6 issues/year) in 1958. It became monthly (12 issues/year) in the year 1964.