Dental Implants: Adjacent Tooth Proximity and Contact.

Dennis Flanagan
{"title":"Dental Implants: Adjacent Tooth Proximity and Contact.","authors":"Dennis Flanagan","doi":"10.1563/aaid-joi-D-24-00188","DOIUrl":null,"url":null,"abstract":"<p><p>During the osteotomy and placement of dental implants, anatomical positions of adjacent natural teeth to a dental implant site may be very close or in actual contact. This can be due to anatomy, the size of the implant site, a misguided osteotomy, drifting, or migration of the adjacent tooth. The implant surgeon needs to be aware of the position of adjacent teeth to avoid root damage from the implant drill or the implant itself. The dimension of 1.5mm space has been discussed, but it is an arbitrary speculative dimension. There is no agreed-upon \"safe\" proximity to adjacent tooth roots. Theoretically, a large displacement size of an implant may inhibit bone remodeling and cause bone loss if placed close to an adjacent tooth. A small diameter or mini-implant may not significantly affect bone remodeling when placed in close proximity or even in contact with an adjacent tooth root. Many factors dictate \"safe\" proximity, including the implant diameter, tooth root displacement, periodontal ligament, bone quality, and patient physiologic factors, including diseases and medications. The degree of root contact by an implant or implant drill may be graded by the contact depth. Grade 1 is contact with periodontal ligament, Grade 2 is contact with periodontal ligament and cementum, Grade 3 is contact with periodontal ligament, cementum, and dentin penetration, and Grade 4 is contact with periodontal ligament, cementum, root dentin, and pulpal penetration. This discussion highlights the need for further research on dental implant proximity and contact with adjacent teeth.</p>","PeriodicalId":519890,"journal":{"name":"The Journal of oral implantology","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of oral implantology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1563/aaid-joi-D-24-00188","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

During the osteotomy and placement of dental implants, anatomical positions of adjacent natural teeth to a dental implant site may be very close or in actual contact. This can be due to anatomy, the size of the implant site, a misguided osteotomy, drifting, or migration of the adjacent tooth. The implant surgeon needs to be aware of the position of adjacent teeth to avoid root damage from the implant drill or the implant itself. The dimension of 1.5mm space has been discussed, but it is an arbitrary speculative dimension. There is no agreed-upon "safe" proximity to adjacent tooth roots. Theoretically, a large displacement size of an implant may inhibit bone remodeling and cause bone loss if placed close to an adjacent tooth. A small diameter or mini-implant may not significantly affect bone remodeling when placed in close proximity or even in contact with an adjacent tooth root. Many factors dictate "safe" proximity, including the implant diameter, tooth root displacement, periodontal ligament, bone quality, and patient physiologic factors, including diseases and medications. The degree of root contact by an implant or implant drill may be graded by the contact depth. Grade 1 is contact with periodontal ligament, Grade 2 is contact with periodontal ligament and cementum, Grade 3 is contact with periodontal ligament, cementum, and dentin penetration, and Grade 4 is contact with periodontal ligament, cementum, root dentin, and pulpal penetration. This discussion highlights the need for further research on dental implant proximity and contact with adjacent teeth.

种植牙:邻近牙齿的接近和接触。
在截骨和种植牙放置过程中,相邻天然牙与种植牙的解剖位置可能非常接近或实际接触。这可能是由于解剖结构,种植体位置的大小,错误的截骨,漂移或邻近牙齿的移动。种植外科医生需要了解邻近牙齿的位置,以避免种植钻或种植体本身对牙根造成损害。1.5mm空间的尺寸已经讨论过了,但这是一个任意推测的尺寸。没有公认的“安全”接近邻近牙根。从理论上讲,大位移的种植体如果放置在邻近牙齿附近,可能会抑制骨重塑并导致骨质流失。小直径种植体或微型种植体在靠近相邻牙根甚至与相邻牙根接触时可能不会显著影响骨重塑。许多因素决定了“安全”的接近程度,包括种植体直径、牙根位移、牙周韧带、骨质量和患者的生理因素,包括疾病和药物。种植体或种植钻与牙根的接触程度可根据接触深度来分级。1级为与牙周韧带接触,2级为与牙周韧带和牙骨质接触,3级为与牙周韧带、牙骨质接触,牙本质渗透,4级为与牙周韧带、牙骨质、牙根牙本质接触,牙髓渗透。这一讨论强调了种植体与邻牙的接近和接触的进一步研究的必要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信