{"title":"Improving Care with the First measurement of high-sensitivity troponin T (ICare-FirsT) to enable early rule out and reduce length of stay: a diagnostic and observational study.","authors":"John W Pickering, Laura Joyce, Gerard Devlin, Chris Pemberton, Richard Troughton, A Mark Richards, Martin P Than","doi":"10.1136/emermed-2024-214754","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Pathways incorporating clinical risk assessment, ECG and serial troponin measurements for the assessment of patients with possible myocardial infarction (MI) in the ED are standard practice. Incorporating a single troponin test to stratify to low risk of MI using a baseline measurement of cardiac troponin (cTn) with a high-sensitivity T assay (hs-cTnT) is recommended. We aimed to implement a pathway incorporating a single-test component and measure the impact on length of stay (LOS).</p><p><strong>Methods: </strong>There were two study phases: (1) Development and performance assessment of a novel pathway incorporating a single-test hs-cTnT stratification using high-fidelity research data, (2) An audit of the implementation of a single-test Roche hs-cTnT strategy within multiple EDs. The low-risk threshold used for hs-cTnT was 5 ng/L. The safety metric was MI or death not known to be non-cardiac within 30 days (MACE30).</p><p><strong>Results: </strong>Phase I: The derived pathway had 16.3% low risk after one blood draw ≥3 hours from symptom onset with hs-cTnT <5 ng/L, non-ischaemic ECG and ED Assessment of Chest pain Score <21.</p><p><strong>Phase ii: </strong>In six hospitals, there were 10 912 patients in the control arm and 13 997 after implementation of single-test hs-cTnT. The unadjusted estimated mean reduction in LOS after intervention was 1.6% (95% CI 0.4% to 2.9%). After adjustment accounting for increased presentations, this was 8.5% (95% CI 7.7% to 9.3%).</p><p><strong>Conclusions: </strong>Within clinical pathways, a single test with a result from an hs-cTnT of <5 ng/L as a component resulted in a small, but meaningful, reduction in mean ED LOS.</p>","PeriodicalId":11532,"journal":{"name":"Emergency Medicine Journal","volume":" ","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2025-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Emergency Medicine Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1136/emermed-2024-214754","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Pathways incorporating clinical risk assessment, ECG and serial troponin measurements for the assessment of patients with possible myocardial infarction (MI) in the ED are standard practice. Incorporating a single troponin test to stratify to low risk of MI using a baseline measurement of cardiac troponin (cTn) with a high-sensitivity T assay (hs-cTnT) is recommended. We aimed to implement a pathway incorporating a single-test component and measure the impact on length of stay (LOS).
Methods: There were two study phases: (1) Development and performance assessment of a novel pathway incorporating a single-test hs-cTnT stratification using high-fidelity research data, (2) An audit of the implementation of a single-test Roche hs-cTnT strategy within multiple EDs. The low-risk threshold used for hs-cTnT was 5 ng/L. The safety metric was MI or death not known to be non-cardiac within 30 days (MACE30).
Results: Phase I: The derived pathway had 16.3% low risk after one blood draw ≥3 hours from symptom onset with hs-cTnT <5 ng/L, non-ischaemic ECG and ED Assessment of Chest pain Score <21.
Phase ii: In six hospitals, there were 10 912 patients in the control arm and 13 997 after implementation of single-test hs-cTnT. The unadjusted estimated mean reduction in LOS after intervention was 1.6% (95% CI 0.4% to 2.9%). After adjustment accounting for increased presentations, this was 8.5% (95% CI 7.7% to 9.3%).
Conclusions: Within clinical pathways, a single test with a result from an hs-cTnT of <5 ng/L as a component resulted in a small, but meaningful, reduction in mean ED LOS.
期刊介绍:
The Emergency Medicine Journal is a leading international journal reporting developments and advances in emergency medicine and acute care. It has relevance to all specialties involved in the management of emergencies in the hospital and prehospital environment. Each issue contains editorials, reviews, original research, evidence based reviews, letters and more.