{"title":"The Use of Composite Xenograft and Allograft in Post-Explantation Ridge Defect Augmentation: A Case Report.","authors":"Hanae Saito, Kaylie Nguyen","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>This case report highlights the successful management of ridge defects resulting from early implant failures through ridge defect augmentation using a composite allograft/xenograft bone substitute following explantation. Subsequent implant placements achieved primary stability within 4 months post-augmentation, enabling the delivery of a prosthesis with a fixed partial denture by 5 months post-implant placement. The unique combination of the demineralized allograft fiber-form and xenograft leveraged the materials' distinct osteoinductive and osteoconductive attributes to facilitate a positive outcome in the ridge defect augmentation. As demonstrated in this case presentation, this composite graft provides both volume stability and structural support for implant-supported prostheses.</p>","PeriodicalId":72651,"journal":{"name":"Compendium of continuing education in dentistry (Jamesburg, N.J. : 1995)","volume":"46 4","pages":"187-190"},"PeriodicalIF":0.0000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Compendium of continuing education in dentistry (Jamesburg, N.J. : 1995)","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This case report highlights the successful management of ridge defects resulting from early implant failures through ridge defect augmentation using a composite allograft/xenograft bone substitute following explantation. Subsequent implant placements achieved primary stability within 4 months post-augmentation, enabling the delivery of a prosthesis with a fixed partial denture by 5 months post-implant placement. The unique combination of the demineralized allograft fiber-form and xenograft leveraged the materials' distinct osteoinductive and osteoconductive attributes to facilitate a positive outcome in the ridge defect augmentation. As demonstrated in this case presentation, this composite graft provides both volume stability and structural support for implant-supported prostheses.