High-speed sintering on monolithic zirconia: Effects on surface and antagonist wear in vitro.

IF 3.4 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Turki Alsubaie, Rayan Ahmed Alhebshi, Abdul Samad Khan, Mohammed M Gad, Abdulrahman A Balhaddad, Haidar Alalawi
{"title":"High-speed sintering on monolithic zirconia: Effects on surface and antagonist wear in vitro.","authors":"Turki Alsubaie, Rayan Ahmed Alhebshi, Abdul Samad Khan, Mohammed M Gad, Abdulrahman A Balhaddad, Haidar Alalawi","doi":"10.1111/jopr.14083","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to assess the influence of zirconia's chemical structure and the sintering method on the wear behavior of the material itself and the opposing enamel.</p><p><strong>Materials and methods: </strong>Two different types of zirconia, 3 mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP (Whitepeaks Dental Solutions Inc., Hamminkeln, Germany) and 5 mol% yttria-stabilized tetragonal zirconia polycrystal (5Y-PSZ) (Whitepeaks Dental Solutions Inc., Hamminkeln, Germany), were fabricated via conventional and high-speed sintering methods and investigated for their wear behavior. The two-body wear of zirconia and opposing enamel was induced using a chewing simulation device under a vertical load of 50 N, and a sliding movement of 0.7 mm until 1,200,000 chewing cycles were achieved. A three-dimensional data measuring software (GeoMagic Control X, 2018) was used to calculate volume loss following cyclic fatigue. Two-way ANOVA and Tukey tests analyzed the data.</p><p><strong>Results: </strong>The results demonstrated that both material types, 3Y-TZP and 5Y-PSZ, and the sintering method, conventional or high-speed sintering, significantly affected the wear of enamel and zirconia (p < 0.001). The amount of enamel wear induced by 3Y-TZP and 5Y-PSZ high-speed sintering zirconia was reported to be 502.91 ± 44.91 and 635.07 ± 78.32 µm, respectively, which was significantly higher (p < 0.001) than the same materials when they were sintered conventionally (12.05 ± 0.90 and 13.40 ± 0.65 µm). Comparing the 3Y-TZP and 5Y-TZP high-speed sintered zirconia, the amount of wear of enamel associated with 5Y-PSZ was significantly higher than 3Y-TZP (p < 0.05). When the zirconia wear behavior was evaluated, minor surface loss of less than 15 µm was observed among all the groups.</p><p><strong>Conclusion: </strong>High-speed sintering of zirconia caused substantial enamel loss and minor wear on the zirconia itself. As a result, clinicians may consider using conventionally sintered zirconia to minimize the wear of the antagonist. Clinicians may consider using conventionally sintered zirconia to minimize the wear of the antagonist and avoid the associated clinical complications.</p>","PeriodicalId":49152,"journal":{"name":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","volume":" ","pages":""},"PeriodicalIF":3.4000,"publicationDate":"2025-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jopr.14083","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study aimed to assess the influence of zirconia's chemical structure and the sintering method on the wear behavior of the material itself and the opposing enamel.

Materials and methods: Two different types of zirconia, 3 mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP (Whitepeaks Dental Solutions Inc., Hamminkeln, Germany) and 5 mol% yttria-stabilized tetragonal zirconia polycrystal (5Y-PSZ) (Whitepeaks Dental Solutions Inc., Hamminkeln, Germany), were fabricated via conventional and high-speed sintering methods and investigated for their wear behavior. The two-body wear of zirconia and opposing enamel was induced using a chewing simulation device under a vertical load of 50 N, and a sliding movement of 0.7 mm until 1,200,000 chewing cycles were achieved. A three-dimensional data measuring software (GeoMagic Control X, 2018) was used to calculate volume loss following cyclic fatigue. Two-way ANOVA and Tukey tests analyzed the data.

Results: The results demonstrated that both material types, 3Y-TZP and 5Y-PSZ, and the sintering method, conventional or high-speed sintering, significantly affected the wear of enamel and zirconia (p < 0.001). The amount of enamel wear induced by 3Y-TZP and 5Y-PSZ high-speed sintering zirconia was reported to be 502.91 ± 44.91 and 635.07 ± 78.32 µm, respectively, which was significantly higher (p < 0.001) than the same materials when they were sintered conventionally (12.05 ± 0.90 and 13.40 ± 0.65 µm). Comparing the 3Y-TZP and 5Y-TZP high-speed sintered zirconia, the amount of wear of enamel associated with 5Y-PSZ was significantly higher than 3Y-TZP (p < 0.05). When the zirconia wear behavior was evaluated, minor surface loss of less than 15 µm was observed among all the groups.

Conclusion: High-speed sintering of zirconia caused substantial enamel loss and minor wear on the zirconia itself. As a result, clinicians may consider using conventionally sintered zirconia to minimize the wear of the antagonist. Clinicians may consider using conventionally sintered zirconia to minimize the wear of the antagonist and avoid the associated clinical complications.

单片氧化锆的高速烧结:对表面和拮抗剂磨损的影响。
目的:研究氧化锆的化学结构和烧结方式对材料本身及对牙釉质磨损性能的影响。材料和方法:通过常规和高速烧结方法制备了两种不同类型的氧化锆,3mol %氧化钇稳定的四方氧化锆多晶(3Y-TZP) (Whitepeaks Dental Solutions Inc., Hamminkeln,德国)和5mol %氧化钇稳定的四方氧化锆多晶(5Y-PSZ) (Whitepeaks Dental Solutions Inc., Hamminkeln,德国),并研究了它们的磨损行为。采用模拟咀嚼装置诱导氧化锆和对立牙釉质在50 N垂直载荷下的双体磨损,滑动移动0.7 mm,达到120万次咀嚼循环。三维数据测量软件(GeoMagic Control X, 2018)用于计算循环疲劳后的体积损失。双因素方差分析和Tukey检验分析数据。结果:3Y-TZP和5Y-PSZ两种材料类型以及常规烧结和高速烧结两种烧结方式对牙釉质和氧化锆的磨损均有显著影响(p结论:氧化锆高速烧结导致牙釉质大量流失,氧化锆本身磨损较小。因此,临床医生可能会考虑使用传统的烧结氧化锆来减少拮抗剂的磨损。临床医生可能会考虑使用传统的烧结氧化锆来减少拮抗剂的磨损并避免相关的临床并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.90
自引率
15.00%
发文量
171
审稿时长
6-12 weeks
期刊介绍: The Journal of Prosthodontics promotes the advanced study and practice of prosthodontics, implant, esthetic, and reconstructive dentistry. It is the official journal of the American College of Prosthodontists, the American Dental Association-recognized voice of the Specialty of Prosthodontics. The journal publishes evidence-based original scientific articles presenting information that is relevant and useful to prosthodontists. Additionally, it publishes reports of innovative techniques, new instructional methodologies, and instructive clinical reports with an interdisciplinary flair. The journal is particularly focused on promoting the study and use of cutting-edge technology and positioning prosthodontists as the early-adopters of new technology in the dental community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信