Krzysztof Szymański , Łukasz Łabieniec , Grzegorz Domański , Piotr Bogorodzki
{"title":"Attenuation of MR spin-echo signal by restricted diffusion confined to a laminar system and a large rectangular box","authors":"Krzysztof Szymański , Łukasz Łabieniec , Grzegorz Domański , Piotr Bogorodzki","doi":"10.1016/j.mri.2025.110446","DOIUrl":null,"url":null,"abstract":"<div><div>We investigate magnetic resonance (MR) signal attenuation caused by confined by restricted diffusion confined to a laminar system and a large rectangular box using the pulsed gradient spin-echo MR method. Applying asymptotic expansions, we derive corrections up to order <span><math><mn>1</mn><mo>/</mo><msup><mi>L</mi><mn>2</mn></msup></math></span>, where <span><math><mi>L</mi></math></span> is the characteristic system size, and show that in the limit of large <span><math><mi>L</mi></math></span>, the attenuation converges to the free diffusion expression. In the fast diffusion regime, where <span><math><msup><mi>γ</mi><mn>2</mn></msup><msup><mi>G</mi><mn>2</mn></msup><msup><mi>δ</mi><mn>2</mn></msup><mi>D</mi><mo>∆</mo><mo>≫</mo><mn>1</mn></math></span>, interference effects become significant, limiting the applicability of the asymptotic expansion. Our findings refine diffusion-weighted MRI models and provide insights into confined molecular transport.</div></div>","PeriodicalId":18165,"journal":{"name":"Magnetic resonance imaging","volume":"122 ","pages":"Article 110446"},"PeriodicalIF":2.1000,"publicationDate":"2025-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic resonance imaging","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0730725X25001304","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
We investigate magnetic resonance (MR) signal attenuation caused by confined by restricted diffusion confined to a laminar system and a large rectangular box using the pulsed gradient spin-echo MR method. Applying asymptotic expansions, we derive corrections up to order , where is the characteristic system size, and show that in the limit of large , the attenuation converges to the free diffusion expression. In the fast diffusion regime, where , interference effects become significant, limiting the applicability of the asymptotic expansion. Our findings refine diffusion-weighted MRI models and provide insights into confined molecular transport.
期刊介绍:
Magnetic Resonance Imaging (MRI) is the first international multidisciplinary journal encompassing physical, life, and clinical science investigations as they relate to the development and use of magnetic resonance imaging. MRI is dedicated to both basic research, technological innovation and applications, providing a single forum for communication among radiologists, physicists, chemists, biochemists, biologists, engineers, internists, pathologists, physiologists, computer scientists, and mathematicians.