{"title":"Optimization of TaqMan-based quantitative PCR diagnosis for Entamoeba histolytica using droplet digital PCR.","authors":"Akira Kawashima, Yasuaki Yanagawa, Takayuki Chikata, Rieko Shimogawara, Daisuke Mizushima, Kiyoto Tsuchiya, Kenji Yagita, Hiroyuki Gatanaga, Koji Watanabe","doi":"10.1371/journal.pntd.0012935","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>TaqMan-probed quantitative PCR (qPCR) is highly valued for diagnosing Entamoeba histolytica infections (amebiasis). However, unclear cycle threshold (Ct) values often yield low-titer positive results, complicating interpretation. This study aimed to optimize qPCR primer-probe sets with logically determined cut-off Ct value using droplet digital PCR (ddPCR).</p><p><strong>Methodology/principal findings: </strong>Amplification efficacy was evaluated using ddPCR by measuring absolute positive droplet counts (APD) and mean fluorescence intensity at different PCR cycles and annealing temperatures (AT). A primer-probe specific cut-off Ct value was determined from a standard curve by correlating Ct values with APD. Twenty primer-probe sets targeting small subunit rRNA gene regions (X64142) were designed from previous papers. Amplification efficacy remained consistent at high PCR cycles (50 cycles), but differed at lower PCR cycles (30 cycles), identifying five sets with higher amplification efficiency than other candidates. Of these, only two sets maintained efficiency at higher AT (62°C). Ct value was inversely proportional to the square of APD, defining the specific cut-off Ct value as 36 cycles. Selected primer-probe set with a cut-off effectively differentiated E. histolytica infection in clinical specimens. However, discordant results between Ct value and APD were seen in some cases with high Ct value. Shotgun metagenomic sequencing suggested microbial-independent false positive reactions contributed to these discrepancies, although specific reactants were unidentified.</p><p><strong>Conclusions/significance: </strong>The combination use of ddPCR with qPCR revealed that false positive reactions of qPCR and/or ddPCR commonly happen in stool specimens. Also, this study emphasizes the value of ddPCR for establishing accurate cut-off values with efficient primer-probes.</p>","PeriodicalId":49000,"journal":{"name":"PLoS Neglected Tropical Diseases","volume":"19 6","pages":"e0012935"},"PeriodicalIF":3.4000,"publicationDate":"2025-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12165414/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"PLoS Neglected Tropical Diseases","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1371/journal.pntd.0012935","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/6/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"PARASITOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: TaqMan-probed quantitative PCR (qPCR) is highly valued for diagnosing Entamoeba histolytica infections (amebiasis). However, unclear cycle threshold (Ct) values often yield low-titer positive results, complicating interpretation. This study aimed to optimize qPCR primer-probe sets with logically determined cut-off Ct value using droplet digital PCR (ddPCR).
Methodology/principal findings: Amplification efficacy was evaluated using ddPCR by measuring absolute positive droplet counts (APD) and mean fluorescence intensity at different PCR cycles and annealing temperatures (AT). A primer-probe specific cut-off Ct value was determined from a standard curve by correlating Ct values with APD. Twenty primer-probe sets targeting small subunit rRNA gene regions (X64142) were designed from previous papers. Amplification efficacy remained consistent at high PCR cycles (50 cycles), but differed at lower PCR cycles (30 cycles), identifying five sets with higher amplification efficiency than other candidates. Of these, only two sets maintained efficiency at higher AT (62°C). Ct value was inversely proportional to the square of APD, defining the specific cut-off Ct value as 36 cycles. Selected primer-probe set with a cut-off effectively differentiated E. histolytica infection in clinical specimens. However, discordant results between Ct value and APD were seen in some cases with high Ct value. Shotgun metagenomic sequencing suggested microbial-independent false positive reactions contributed to these discrepancies, although specific reactants were unidentified.
Conclusions/significance: The combination use of ddPCR with qPCR revealed that false positive reactions of qPCR and/or ddPCR commonly happen in stool specimens. Also, this study emphasizes the value of ddPCR for establishing accurate cut-off values with efficient primer-probes.
期刊介绍:
PLOS Neglected Tropical Diseases publishes research devoted to the pathology, epidemiology, prevention, treatment and control of the neglected tropical diseases (NTDs), as well as relevant public policy.
The NTDs are defined as a group of poverty-promoting chronic infectious diseases, which primarily occur in rural areas and poor urban areas of low-income and middle-income countries. Their impact on child health and development, pregnancy, and worker productivity, as well as their stigmatizing features limit economic stability.
All aspects of these diseases are considered, including:
Pathogenesis
Clinical features
Pharmacology and treatment
Diagnosis
Epidemiology
Vector biology
Vaccinology and prevention
Demographic, ecological and social determinants
Public health and policy aspects (including cost-effectiveness analyses).