Hannes Vermue, Guillaume Mesnard, Elvire Servien, Cécile Batailler, Sébastien Lustig
{"title":"Rotating-platform deep-dish total knee arthroplasty with restricted kinematic alignment: Five-year clinical and functional outcomes.","authors":"Hannes Vermue, Guillaume Mesnard, Elvire Servien, Cécile Batailler, Sébastien Lustig","doi":"10.1051/sicotj/2025018","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Total knee arthroplasty (TKA) utilizing deep-dish tibial inserts has gained interest due to its high congruency and enhanced stability. However, due to the advent of more personalized alignment philosophies, the combination of a rotating-platform deep-dish TKA design with restricted kinematic alignment (rKA) might improve patient satisfaction. Therefore, this study evaluated the five-year clinical and functional outcomes of rKA with a deep-dish TKA design.</p><p><strong>Methods: </strong>A retrospective analysis was conducted on patients who underwent primary TKA with a rotating-platform deep-dish design and rKA. Of 143 eligible patients, 123 completed five-year follow-up. Clinical and radiographic assessments included the five-year postoperative results: Knee Society Score (KSS), patient satisfaction, range of motion, coronal limb and implant alignment, postoperative complications and implant survivorship. Statistical analyses compared preoperative and postoperative outcomes with paired analyses.</p><p><strong>Results: </strong>Median KSS Knee and Function scores significantly improved from 70 (IQR 5) and 60 (IQR 26) preoperatively to 90 (IQR 20) and 93 (IQR 21) postoperatively (p < 0.001). Postoperative coronal alignment in this study encompassed a hip-knee-ankle angle was 178.1° ± 3.5, a Lateral Distal Femoral Angle of 89.9° ± 2.6, and a Medial Proximal Tibial Angle of 88.6° ± 2.2. At five years, 94% of patients were either satisfied or very satisfied. The revision-free survival rate was 98%. Periprosthetic joint infection and arthrofibrosis were the most common complications (1.6% for both groups separately), followed by aseptic loosening of a cementless femoral component (0.8%) and patellar dislocation (0.8%).</p><p><strong>Discussion: </strong>Rotating-platform deep-dish TKA with restricted kinematic alignment results in excellent functional outcomes, high patient satisfaction, and low complication rates at five-year follow-up. These findings support its viability as a surgical strategy, though long-term studies are warranted to assess implant durability and survivorship beyond 10 years.</p>","PeriodicalId":46378,"journal":{"name":"SICOT-J","volume":"11 ","pages":"33"},"PeriodicalIF":1.8000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12143128/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SICOT-J","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/sicotj/2025018","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/6/6 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Total knee arthroplasty (TKA) utilizing deep-dish tibial inserts has gained interest due to its high congruency and enhanced stability. However, due to the advent of more personalized alignment philosophies, the combination of a rotating-platform deep-dish TKA design with restricted kinematic alignment (rKA) might improve patient satisfaction. Therefore, this study evaluated the five-year clinical and functional outcomes of rKA with a deep-dish TKA design.
Methods: A retrospective analysis was conducted on patients who underwent primary TKA with a rotating-platform deep-dish design and rKA. Of 143 eligible patients, 123 completed five-year follow-up. Clinical and radiographic assessments included the five-year postoperative results: Knee Society Score (KSS), patient satisfaction, range of motion, coronal limb and implant alignment, postoperative complications and implant survivorship. Statistical analyses compared preoperative and postoperative outcomes with paired analyses.
Results: Median KSS Knee and Function scores significantly improved from 70 (IQR 5) and 60 (IQR 26) preoperatively to 90 (IQR 20) and 93 (IQR 21) postoperatively (p < 0.001). Postoperative coronal alignment in this study encompassed a hip-knee-ankle angle was 178.1° ± 3.5, a Lateral Distal Femoral Angle of 89.9° ± 2.6, and a Medial Proximal Tibial Angle of 88.6° ± 2.2. At five years, 94% of patients were either satisfied or very satisfied. The revision-free survival rate was 98%. Periprosthetic joint infection and arthrofibrosis were the most common complications (1.6% for both groups separately), followed by aseptic loosening of a cementless femoral component (0.8%) and patellar dislocation (0.8%).
Discussion: Rotating-platform deep-dish TKA with restricted kinematic alignment results in excellent functional outcomes, high patient satisfaction, and low complication rates at five-year follow-up. These findings support its viability as a surgical strategy, though long-term studies are warranted to assess implant durability and survivorship beyond 10 years.