Cementless versus cemented fixation in image-based robotic total knee arthroplasty guided by functional knee positioning principles.

IF 1.8 Q2 ORTHOPEDICS
SICOT-J Pub Date : 2025-01-01 Epub Date: 2025-05-27 DOI:10.1051/sicotj/2025027
Christos Koutserimpas, Pietro Gregori, Enejd Veizi, Luca Andriollo, Elvire Servien, Cécile Batailler, Sébastien Lustig
{"title":"Cementless versus cemented fixation in image-based robotic total knee arthroplasty guided by functional knee positioning principles.","authors":"Christos Koutserimpas, Pietro Gregori, Enejd Veizi, Luca Andriollo, Elvire Servien, Cécile Batailler, Sébastien Lustig","doi":"10.1051/sicotj/2025027","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Under functional knee positioning (FKPos) principles, residual varus or valgus alignment of the tibia and femur may be maintained, resulting in loading conditions that differ from those observed with mechanical alignment. Consequently, there is a need for evidence regarding implant fixation (cemented or cementless) in this context. This study aimed to evaluate the impact of implant fixation type (cemented versus cementless) on clinical outcomes, complications, and implant survival in robotic-assisted total knee arthroplasty (TKA) guided by FKPos principles.</p><p><strong>Methods: </strong>A retrospective comparative analysis of 393 patients who underwent robotic-assisted primary TKA was performed. Patients were divided into two groups: cemented (n = 85) and cementless (n =276) fixation. Radiographic alignment, functional outcomes using the Knee Society Score (KSS) and Forgotten Joint Score (FJS), complication rates, and implant survival were assessed at a minimum 2-year follow-up. Subgroup analyses based on femoral and tibial fixation types were also conducted.</p><p><strong>Results: </strong>Both fixation methods achieved comparable functional outcomes (KSS and FJS) and implant survivorship, with no significant differences in revision rates. Hematomas were significantly more frequent in the cementless group (12.32% vs. 8.24%, p = 0.02). Subgroup analyses of femoral and tibial implants showed no significant differences in functional outcomes.</p><p><strong>Discussion: </strong>This study is the first to assess the influence of fixation type on outcomes in robotic-assisted TKA performed under FKPos principles. Both cemented and cementless fixation methods are safe and effective.</p>","PeriodicalId":46378,"journal":{"name":"SICOT-J","volume":"11 ","pages":"32"},"PeriodicalIF":1.8000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12108099/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SICOT-J","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/sicotj/2025027","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/5/27 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Under functional knee positioning (FKPos) principles, residual varus or valgus alignment of the tibia and femur may be maintained, resulting in loading conditions that differ from those observed with mechanical alignment. Consequently, there is a need for evidence regarding implant fixation (cemented or cementless) in this context. This study aimed to evaluate the impact of implant fixation type (cemented versus cementless) on clinical outcomes, complications, and implant survival in robotic-assisted total knee arthroplasty (TKA) guided by FKPos principles.

Methods: A retrospective comparative analysis of 393 patients who underwent robotic-assisted primary TKA was performed. Patients were divided into two groups: cemented (n = 85) and cementless (n =276) fixation. Radiographic alignment, functional outcomes using the Knee Society Score (KSS) and Forgotten Joint Score (FJS), complication rates, and implant survival were assessed at a minimum 2-year follow-up. Subgroup analyses based on femoral and tibial fixation types were also conducted.

Results: Both fixation methods achieved comparable functional outcomes (KSS and FJS) and implant survivorship, with no significant differences in revision rates. Hematomas were significantly more frequent in the cementless group (12.32% vs. 8.24%, p = 0.02). Subgroup analyses of femoral and tibial implants showed no significant differences in functional outcomes.

Discussion: This study is the first to assess the influence of fixation type on outcomes in robotic-assisted TKA performed under FKPos principles. Both cemented and cementless fixation methods are safe and effective.

在功能性膝关节定位原则指导下,基于图像的机器人全膝关节置换术中的无骨水泥与骨水泥固定。
简介:在功能性膝关节定位(FKPos)原则下,胫骨和股骨的残余内翻或外翻对齐可能保持不变,导致与机械对齐所观察到的负载条件不同。因此,在这种情况下,需要关于种植体固定(骨水泥或无骨水泥)的证据。本研究旨在评估在FKPos原则指导下,机器人辅助全膝关节置换术(TKA)中,假体固定类型(骨水泥与无骨水泥)对临床结果、并发症和假体存活的影响。方法:对393例接受机器人辅助的原发性TKA患者进行回顾性比较分析。患者分为两组:骨水泥固定(85例)和无骨水泥固定(276例)。在至少2年的随访中评估影像学对齐、膝关节社会评分(KSS)和遗忘关节评分(FJS)的功能结果、并发症发生率和植入物存活率。根据股骨和胫骨固定类型进行亚组分析。结果:两种固定方法都获得了相当的功能结果(KSS和FJS)和种植体存活,翻修率无显著差异。无骨水泥组血肿发生率明显高于无骨水泥组(12.32%比8.24%,p = 0.02)。股骨和胫骨植入物的亚组分析显示功能结果无显著差异。讨论:本研究首次评估了固定类型对FKPos原则下机器人辅助TKA结果的影响。骨水泥和非骨水泥的固定方法都是安全有效的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
SICOT-J
SICOT-J ORTHOPEDICS-
CiteScore
3.20
自引率
12.50%
发文量
44
审稿时长
14 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信