Felice Lorusso, Sergio Alexandre Gehrke, Sergio Rexhep Tari, Antonio Scarano
{"title":"Fracture Strength of Conometric Joint Implants Versus Internal Hexagon Abutment Joint Design: An In Vitro Study.","authors":"Felice Lorusso, Sergio Alexandre Gehrke, Sergio Rexhep Tari, Antonio Scarano","doi":"10.1563/aaid-joi-D-25-00001","DOIUrl":null,"url":null,"abstract":"<p><p>The dental implant is an effective long-term procedure for oral edentulism due to its efficacy to support functional masticatory loading forces. The implant prosthetic joint is considered a key factor for interface stability due to its biological and biomechanical implications. The present investigation aimed to evaluate the fracture strength of 2 different implant prosthetic joints. This investigation tested 10 implants for each group: a conometric implant joint (group I) and internal hexagon implant (group II). The implant abutment joint was coupled using a calibrated torquemeter. The samples were assessed using a loading fracture test and radiographically evaluated to observe the interface changes and deformations. The means and standard deviations of the group I and group II maximum force (N) were 553 ± 51 N and 432 ± 43 N. The Young elastic modulus of group I and group II implants were 183.97 ± 11.71 GPa and 143.72 ± 15.93 GPa. The conometric joint was reported to have a higher strength than the regular internal hexagon implant connection. The study findings could have clinical implications for implant durability and peri-implant tissue stability in favor of the conical joint design.</p>","PeriodicalId":519890,"journal":{"name":"The Journal of oral implantology","volume":" ","pages":"356-360"},"PeriodicalIF":1.3000,"publicationDate":"2025-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of oral implantology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1563/aaid-joi-D-25-00001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The dental implant is an effective long-term procedure for oral edentulism due to its efficacy to support functional masticatory loading forces. The implant prosthetic joint is considered a key factor for interface stability due to its biological and biomechanical implications. The present investigation aimed to evaluate the fracture strength of 2 different implant prosthetic joints. This investigation tested 10 implants for each group: a conometric implant joint (group I) and internal hexagon implant (group II). The implant abutment joint was coupled using a calibrated torquemeter. The samples were assessed using a loading fracture test and radiographically evaluated to observe the interface changes and deformations. The means and standard deviations of the group I and group II maximum force (N) were 553 ± 51 N and 432 ± 43 N. The Young elastic modulus of group I and group II implants were 183.97 ± 11.71 GPa and 143.72 ± 15.93 GPa. The conometric joint was reported to have a higher strength than the regular internal hexagon implant connection. The study findings could have clinical implications for implant durability and peri-implant tissue stability in favor of the conical joint design.