Enhancing the quality and safety of central venous catheter insertion using projection mapping: a prospective observational simulation study with eye-tracking glasses.

IF 2.4 3区 医学 Q1 MEDICINE, GENERAL & INTERNAL
Atsushi Miyazaki, Arisa Fujii, Daisuke Kuwabara, Kazuhiro Minoguchi, Hiromasa Kawakami, Kyota Nakamura, Keiko Tsuchiya, Takeru Abe, Kazue Nakajima, Hitoshi Sato, Takahisa Goto
{"title":"Enhancing the quality and safety of central venous catheter insertion using projection mapping: a prospective observational simulation study with eye-tracking glasses.","authors":"Atsushi Miyazaki, Arisa Fujii, Daisuke Kuwabara, Kazuhiro Minoguchi, Hiromasa Kawakami, Kyota Nakamura, Keiko Tsuchiya, Takeru Abe, Kazue Nakajima, Hitoshi Sato, Takahisa Goto","doi":"10.1136/bmjopen-2024-095803","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>We aimed to evaluate the effect of projection mapping (PM) on the quality and safety of central venous catheter (CVC) insertion under real-time ultrasound guidance.</p><p><strong>Design: </strong>Prospective, observational, simulation study.</p><p><strong>Setting: </strong>This study was conducted at the Yokohama City University Medical Center (Yokohama, Japan). Volunteer residents were enrolled over 12 months from January to December 2023.</p><p><strong>Participants and methods: </strong>12 rotating residents (postgraduation year (PGY) 1 and 2) and eight anaesthesia residents (PGY 3-5) placed the CVC in the internal jugular vein in a simulator under the real-time ultrasound guidance using the short-axis out-of-plane approach. The ultrasound image was provided either just caudad to the puncture site using the PM method or on the monitor of the ultrasound machine (conventional method) placed next to the simulator's right shoulder. Each resident performed four punctures alternating between the PM and conventional methods, and the first method for each resident was chosen randomly. Eye-tracking analysis was also used to evaluate differences in gaze behaviour.</p><p><strong>Primary and secondary outcome measures: </strong>The primary outcome was the procedure time defined as the time from the application of the ultrasound probe on the puncture field until successful puncture of the vein. The secondary outcomes were incidence of complications and eye-tracking analysis data.</p><p><strong>Results: </strong>The time to complete the line placement was significantly shorter for the PM than for the conventional method (median (IQR) 22.5 (15.5-30.6) s vs 30.0 (20.4-95.4) s; p=0.02, Wilcoxon's signed-rank test). The incidence of posterior vessel wall puncture was significantly lower in the PM method (0% vs 25%; p=0.02, McNemar's test). Eye-tracking analysis revealed that the percentage of time spent gazing at the ultrasound image was higher in the PM than in the conventional method (61.6% (55.0-69.2) vs 45.7% (34.1-54.5); p<0.01).</p><p><strong>Conclusions: </strong>The PM method facilitates ultrasound-guided CVC placement while preventing excessive needle advancement in the inexperienced operators. This was accompanied by enhanced fixation of the participants' line-of-sight on the ultrasound image.</p>","PeriodicalId":9158,"journal":{"name":"BMJ Open","volume":"15 5","pages":"e095803"},"PeriodicalIF":2.4000,"publicationDate":"2025-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMJ Open","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1136/bmjopen-2024-095803","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: We aimed to evaluate the effect of projection mapping (PM) on the quality and safety of central venous catheter (CVC) insertion under real-time ultrasound guidance.

Design: Prospective, observational, simulation study.

Setting: This study was conducted at the Yokohama City University Medical Center (Yokohama, Japan). Volunteer residents were enrolled over 12 months from January to December 2023.

Participants and methods: 12 rotating residents (postgraduation year (PGY) 1 and 2) and eight anaesthesia residents (PGY 3-5) placed the CVC in the internal jugular vein in a simulator under the real-time ultrasound guidance using the short-axis out-of-plane approach. The ultrasound image was provided either just caudad to the puncture site using the PM method or on the monitor of the ultrasound machine (conventional method) placed next to the simulator's right shoulder. Each resident performed four punctures alternating between the PM and conventional methods, and the first method for each resident was chosen randomly. Eye-tracking analysis was also used to evaluate differences in gaze behaviour.

Primary and secondary outcome measures: The primary outcome was the procedure time defined as the time from the application of the ultrasound probe on the puncture field until successful puncture of the vein. The secondary outcomes were incidence of complications and eye-tracking analysis data.

Results: The time to complete the line placement was significantly shorter for the PM than for the conventional method (median (IQR) 22.5 (15.5-30.6) s vs 30.0 (20.4-95.4) s; p=0.02, Wilcoxon's signed-rank test). The incidence of posterior vessel wall puncture was significantly lower in the PM method (0% vs 25%; p=0.02, McNemar's test). Eye-tracking analysis revealed that the percentage of time spent gazing at the ultrasound image was higher in the PM than in the conventional method (61.6% (55.0-69.2) vs 45.7% (34.1-54.5); p<0.01).

Conclusions: The PM method facilitates ultrasound-guided CVC placement while preventing excessive needle advancement in the inexperienced operators. This was accompanied by enhanced fixation of the participants' line-of-sight on the ultrasound image.

利用投影映射提高中心静脉导管置入的质量和安全性:一项眼动追踪眼镜的前瞻性观察模拟研究。
目的:探讨实时超声引导下投影定位(PM)对中心静脉导管(CVC)置管质量和安全性的影响。设计:前瞻性、观察性、模拟研究。背景:本研究在横滨市立大学医学中心(横滨,日本)进行。志愿者在2023年1月至12月的12个月内被招募。参与者和方法:12名轮转住院医师(毕业后1、2年级)和8名麻醉住院医师(3 ~ 5年级)在实时超声引导下,采用短轴平面外入路将CVC放置于模拟器内颈内静脉。超声图像要么使用PM方法在穿刺部位的尾部提供,要么在放置在模拟器右肩旁边的超声仪(传统方法)的监视器上提供。每位住院医师在PM和常规方法之间交替进行四次穿刺,随机选择每位住院医师的第一种方法。眼球追踪分析也用于评估凝视行为的差异。主要和次要观察指标:主要观察指标为手术时间,定义为超声探头在穿刺场应用至静脉穿刺成功的时间。次要结局为并发症发生率和眼动分析数据。结果:PM完成线放置的时间明显短于常规方法(中位(IQR) 22.5 (15.5-30.6) s vs 30.0 (20.4-95.4) s;p=0.02, Wilcoxon's sign -rank检验)。PM法后血管壁穿刺发生率明显较低(0% vs 25%;p=0.02, McNemar检验)。眼球追踪分析显示,PM时注视超声图像的时间百分比高于常规方法(61.6% (55.0-69.2)vs 45.7% (34.1-54.5);结论:PM方法有助于超声引导CVC放置,同时防止无经验的操作人员针头过度推进。这伴随着参与者在超声图像上的视线的增强固定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
BMJ Open
BMJ Open MEDICINE, GENERAL & INTERNAL-
CiteScore
4.40
自引率
3.40%
发文量
4510
审稿时长
2-3 weeks
期刊介绍: BMJ Open is an online, open access journal, dedicated to publishing medical research from all disciplines and therapeutic areas. The journal publishes all research study types, from study protocols to phase I trials to meta-analyses, including small or specialist studies. Publishing procedures are built around fully open peer review and continuous publication, publishing research online as soon as the article is ready.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信