{"title":"[Validation of Quantitative Evaluation Method Using a Cadmium Zinc Telluride Cardiac Camera in the Diagnosis of Cardiac Amyloidosis].","authors":"Hoshio Uwabe, Nobuhiro Yada, Yuki Hino, Shoko Konishi, Hideaki Watanabe, Yoshinori Miyahara, Yasushi Kaji","doi":"10.6009/jjrt.25-1546","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this study was to verify the clinical applicability of PYP accumulation rates obtained with a cadmium zinc telluride (CZT) cardiac camera in the diagnosis of cardiac amyloidosis.</p><p><strong>Methods: </strong>We performed <sup>99m</sup>Tc-PYP/<sup>201</sup>Tl-Cl dual-isotope imaging in 84 patients with suspected cardiac amyloidosis using both a CZT cardiac camera and a conventional Anger camera. We obtained the PYP accumulation rate from CZT SPECT images and visual score and H/CL ratio from planar images. We evaluated PYP accumulation rates in 14 ATTR and 9 non-ATTR patients diagnosed by biopsy. We also evaluated the correlation between the PYP accumulation rate and both the visual assessment grade and H/CL ratio in 84 patients.</p><p><strong>Results: </strong>The PYP accumulation rate was 18.5±10.6% in the non-ATTR group and 72.4±28.7% in the ATTR group, which was significantly higher in the ATTR group (p<0.01). The correlation coefficient between the PYP accumulation rate and visual score was 0.77, and that of the H/CL ratio was 0.76, both showing strong positive correlations.</p><p><strong>Conclusion: </strong>The PYP accumulation rate obtained with a CZT cardiac camera showed significant differences between ATTR and non-ATTR groups and strong correlations with conventional assessment indices, suggesting its potential applicability in the diagnosis of cardiac amyloidosis.</p>","PeriodicalId":74309,"journal":{"name":"Nihon Hoshasen Gijutsu Gakkai zasshi","volume":"81 7","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nihon Hoshasen Gijutsu Gakkai zasshi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.6009/jjrt.25-1546","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: The purpose of this study was to verify the clinical applicability of PYP accumulation rates obtained with a cadmium zinc telluride (CZT) cardiac camera in the diagnosis of cardiac amyloidosis.
Methods: We performed 99mTc-PYP/201Tl-Cl dual-isotope imaging in 84 patients with suspected cardiac amyloidosis using both a CZT cardiac camera and a conventional Anger camera. We obtained the PYP accumulation rate from CZT SPECT images and visual score and H/CL ratio from planar images. We evaluated PYP accumulation rates in 14 ATTR and 9 non-ATTR patients diagnosed by biopsy. We also evaluated the correlation between the PYP accumulation rate and both the visual assessment grade and H/CL ratio in 84 patients.
Results: The PYP accumulation rate was 18.5±10.6% in the non-ATTR group and 72.4±28.7% in the ATTR group, which was significantly higher in the ATTR group (p<0.01). The correlation coefficient between the PYP accumulation rate and visual score was 0.77, and that of the H/CL ratio was 0.76, both showing strong positive correlations.
Conclusion: The PYP accumulation rate obtained with a CZT cardiac camera showed significant differences between ATTR and non-ATTR groups and strong correlations with conventional assessment indices, suggesting its potential applicability in the diagnosis of cardiac amyloidosis.