Quantification of Metamorphopsia Using a Smartphone-Based Hyperacuity Test in Patients With Idiopathic Epiretinal Membranes: Prospective Observational Study.

Daria Amon, Christoph Leisser, Andreas Schlatter, Manuel Ruiss, Caroline Pilwachs, Natascha Bayer, Josef Huemer, Oliver Findl
{"title":"Quantification of Metamorphopsia Using a Smartphone-Based Hyperacuity Test in Patients With Idiopathic Epiretinal Membranes: Prospective Observational Study.","authors":"Daria Amon, Christoph Leisser, Andreas Schlatter, Manuel Ruiss, Caroline Pilwachs, Natascha Bayer, Josef Huemer, Oliver Findl","doi":"10.2196/60959","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Quality of vision in patients with idiopathic epiretinal membranes (iERMs) is closely linked to distorted vision (metamorphopsia), which is often underestimated in clinical settings. Current surgical decision-making relies heavily on visual acuity and optical coherence tomography findings, which do not adequately reflect the patient's functional vision or the severity of metamorphopsia. There is a clinical need for tools that can reliably quantify this symptom to improve patient outcomes and streamline care pathways.</p><p><strong>Objectives: </strong>This study is the first to assess the use of a novel smartphone-based hyperacuity test (SHT) in quantifying metamorphopsia before and after surgical intervention for iERMs, comparing it with a conventional printed chart.</p><p><strong>Methods: </strong>This prospective observational study included 27 patients with iERMs with symptomatic metamorphopsia detected on the Amsler grid scheduled for vitrectomy with membrane peeling. The SHT (Alleye, Oculocare Medical Inc) and the horizontal (MH) and vertical (MV) M-chart (Inami & Co, Ltd) tests were performed 3 times before and 3 months after surgery. Pre- and postoperative metamorphopsia scores, changes in distance-corrected visual acuity, optical coherence tomography biomarkers, and subjective perception of metamorphopsia were evaluated.</p><p><strong>Results: </strong>The mean SHT score significantly (r=0.686; P<.001) improved from 55.2 (SD 18.9) before surgery to 63.5 (SD 16.3) after surgery while the improvement of the M-chart scores were insignificant (MH r=0.37, P=.06; MV r=0.18, P=.36). Pre- and postoperative SHT scores showed very weak and insignificant correlations with the MH, MV, and MH+MV scores. Both metamorphopsia tests showed good reliability (intraclass correlation coefficients >0.75).</p><p><strong>Conclusions: </strong>The SHT showed a significant improvement in postoperative metamorphopsia scores, indicating that it could be a valuable tool for quantifying visual distortion in patients with iERMs. While discrepancies with M-chart results were observed, both tests demonstrated good reliability. Clinically, the SHT may offer a practical solution for monitoring metamorphopsia and guiding complex surgical decision-making, particularly in telemedicine settings. Its accessibility could improve patient management, potentially enhancing preoperative triaging and reducing unnecessary visits.</p>","PeriodicalId":73557,"journal":{"name":"JMIR perioperative medicine","volume":"8 ","pages":"e60959"},"PeriodicalIF":0.0000,"publicationDate":"2025-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12021372/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JMIR perioperative medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2196/60959","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Quality of vision in patients with idiopathic epiretinal membranes (iERMs) is closely linked to distorted vision (metamorphopsia), which is often underestimated in clinical settings. Current surgical decision-making relies heavily on visual acuity and optical coherence tomography findings, which do not adequately reflect the patient's functional vision or the severity of metamorphopsia. There is a clinical need for tools that can reliably quantify this symptom to improve patient outcomes and streamline care pathways.

Objectives: This study is the first to assess the use of a novel smartphone-based hyperacuity test (SHT) in quantifying metamorphopsia before and after surgical intervention for iERMs, comparing it with a conventional printed chart.

Methods: This prospective observational study included 27 patients with iERMs with symptomatic metamorphopsia detected on the Amsler grid scheduled for vitrectomy with membrane peeling. The SHT (Alleye, Oculocare Medical Inc) and the horizontal (MH) and vertical (MV) M-chart (Inami & Co, Ltd) tests were performed 3 times before and 3 months after surgery. Pre- and postoperative metamorphopsia scores, changes in distance-corrected visual acuity, optical coherence tomography biomarkers, and subjective perception of metamorphopsia were evaluated.

Results: The mean SHT score significantly (r=0.686; P<.001) improved from 55.2 (SD 18.9) before surgery to 63.5 (SD 16.3) after surgery while the improvement of the M-chart scores were insignificant (MH r=0.37, P=.06; MV r=0.18, P=.36). Pre- and postoperative SHT scores showed very weak and insignificant correlations with the MH, MV, and MH+MV scores. Both metamorphopsia tests showed good reliability (intraclass correlation coefficients >0.75).

Conclusions: The SHT showed a significant improvement in postoperative metamorphopsia scores, indicating that it could be a valuable tool for quantifying visual distortion in patients with iERMs. While discrepancies with M-chart results were observed, both tests demonstrated good reliability. Clinically, the SHT may offer a practical solution for monitoring metamorphopsia and guiding complex surgical decision-making, particularly in telemedicine settings. Its accessibility could improve patient management, potentially enhancing preoperative triaging and reducing unnecessary visits.

在特发性视网膜上膜患者中使用基于智能手机的高敏度测试量化变形:前瞻性观察研究。
背景:特发性视网膜前膜(iERMs)患者的视力质量与视力扭曲(变形)密切相关,在临床环境中经常被低估。目前的手术决策在很大程度上依赖于视力和光学相干断层扫描结果,这些结果不能充分反映患者的功能视力或变形视的严重程度。临床需要能够可靠地量化这种症状的工具,以改善患者的预后并简化护理途径。目的:本研究首次评估了一种新型的基于智能手机的超视力测试(SHT)在ierm手术干预前后量化变形的应用,并将其与传统的印刷图表进行了比较。方法:本前瞻性观察研究纳入27例在Amsler网格上检测到症状性变形的ierm患者,计划进行玻璃体切除术并剥离膜。术前和术后3个月分别进行3次SHT (Alleye, Oculocare Medical Inc .)和水平(MH)和垂直(MV) m图(Inami & Co . Ltd .)测试。评估术前和术后变形评分、距离矫正视力的变化、光学相干断层扫描生物标志物和对变形的主观感知。结果:SHT平均评分显著(r=0.686;P0.75)。结论:SHT在术后变形评分中有显著改善,表明它可以作为一种量化ierm患者视觉畸变的有价值的工具。虽然观察到与m图结果的差异,但两个测试都显示出良好的可靠性。在临床上,SHT可能为监测变形和指导复杂的手术决策提供实用的解决方案,特别是在远程医疗环境中。它的可及性可以改善患者管理,潜在地加强术前分诊和减少不必要的就诊。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.50
自引率
0.00%
发文量
0
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信