Biomechanics of the implant-supported full arch fixed complete denture manufactured by milling and injection techniques: An experimental and FEA study.

IF 3.4 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Mustafa Gürkan, Ovul Kumbuloglu, Makbule Heval Şahan, Mert Narin, Halis Kandaş, Yusuf Arman, Hasan Yildiz, Mahmut Pekedis
{"title":"Biomechanics of the implant-supported full arch fixed complete denture manufactured by milling and injection techniques: An experimental and FEA study.","authors":"Mustafa Gürkan, Ovul Kumbuloglu, Makbule Heval Şahan, Mert Narin, Halis Kandaş, Yusuf Arman, Hasan Yildiz, Mahmut Pekedis","doi":"10.1111/jopr.14058","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aims to characterize the mechanical properties of implant-supported full arch fixed complete dentures manufactured by milling and injection techniques.</p><p><strong>Materials and methods: </strong>Twenty-two samples with milling and injection manufacturing techniques were fabricated. Twenty-two titanium samples were manufactured to be used as the control group. Additionally, eight PEEK samples from both the injection and milling groups were manufactured and tested using a uniaxial tensile test, and the obtained results were used as input data for finite element analysis (FEA). All-on-four PEEK hybrid prostheses supported with 2 implants on the mandible were used for the simulations. The FEA computations were performed for a bilateral 150 N force applied in both vertical and oblique directions.</p><p><strong>Results: </strong>A significant difference was observed between the injection and milled PEEK groups in terms of modulus of elasticity (Injection PEEK group: 3.1 ± 0.6 GPa, Milling PEEK: 4.6 ± 0.9 GPa) and flexural rigidity (Injection PEEK group: 28.0 ± 5.8 kNmm<sup>2</sup>, Milling PEEK: 41.2 ± 8.4 kNmm<sup>2</sup>) (p < 0.05), while no significant differences were observed between the injection and milled PEEK groups in terms of other parameters (p > 0.05). The finite element results showed that the highest stresses were observed in the Injection PEEK group, while the lowest were observed in the Milling Titanium group. Both injection and milled PEEK frameworks exceeded the yield stress limit during vertical and oblique loading.</p><p><strong>Conclusion: </strong>It was concluded that the forces implemented on rigid framework material such as titanium were better distributed to the implants supporting the all-on-four prosthesis.</p>","PeriodicalId":49152,"journal":{"name":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","volume":" ","pages":""},"PeriodicalIF":3.4000,"publicationDate":"2025-04-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jopr.14058","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study aims to characterize the mechanical properties of implant-supported full arch fixed complete dentures manufactured by milling and injection techniques.

Materials and methods: Twenty-two samples with milling and injection manufacturing techniques were fabricated. Twenty-two titanium samples were manufactured to be used as the control group. Additionally, eight PEEK samples from both the injection and milling groups were manufactured and tested using a uniaxial tensile test, and the obtained results were used as input data for finite element analysis (FEA). All-on-four PEEK hybrid prostheses supported with 2 implants on the mandible were used for the simulations. The FEA computations were performed for a bilateral 150 N force applied in both vertical and oblique directions.

Results: A significant difference was observed between the injection and milled PEEK groups in terms of modulus of elasticity (Injection PEEK group: 3.1 ± 0.6 GPa, Milling PEEK: 4.6 ± 0.9 GPa) and flexural rigidity (Injection PEEK group: 28.0 ± 5.8 kNmm2, Milling PEEK: 41.2 ± 8.4 kNmm2) (p < 0.05), while no significant differences were observed between the injection and milled PEEK groups in terms of other parameters (p > 0.05). The finite element results showed that the highest stresses were observed in the Injection PEEK group, while the lowest were observed in the Milling Titanium group. Both injection and milled PEEK frameworks exceeded the yield stress limit during vertical and oblique loading.

Conclusion: It was concluded that the forces implemented on rigid framework material such as titanium were better distributed to the implants supporting the all-on-four prosthesis.

用铣削和注射技术制造种植支撑全弓固定义齿的生物力学实验和有限元分析。
目的:研究采用铣削和注射技术制备的种植全弓固定义齿的力学性能。材料和方法:采用铣削和注射工艺制备了22个样品。制备钛样品22个作为对照组。此外,从注塑组和铣削组制造了8个PEEK样品,并使用单轴拉伸试验进行测试,获得的结果用作有限元分析(FEA)的输入数据。采用4 -on- 4聚醚醚酮复合假体和2个种植体支撑下颌骨进行模拟。在垂直和斜向作用下,进行了双边150n力的有限元计算。结果:在弹性模量(注射PEEK组:3.1±0.6 GPa,铣削PEEK组:4.6±0.9 GPa)和抗弯刚度(注射PEEK组:28.0±5.8 kNmm2,铣削PEEK组:41.2±8.4 kNmm2)方面,注射组与铣削PEEK组有显著差异(p 0.05)。有限元结果表明,注射PEEK组的应力最大,而铣削钛合金组的应力最小。在垂直和斜向载荷下,注塑和铣削PEEK框架均超过屈服应力极限。结论:在钛等刚性骨架材料上施加的力能更好地分配到支撑全上四口义肢的种植体上。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.90
自引率
15.00%
发文量
171
审稿时长
6-12 weeks
期刊介绍: The Journal of Prosthodontics promotes the advanced study and practice of prosthodontics, implant, esthetic, and reconstructive dentistry. It is the official journal of the American College of Prosthodontists, the American Dental Association-recognized voice of the Specialty of Prosthodontics. The journal publishes evidence-based original scientific articles presenting information that is relevant and useful to prosthodontists. Additionally, it publishes reports of innovative techniques, new instructional methodologies, and instructive clinical reports with an interdisciplinary flair. The journal is particularly focused on promoting the study and use of cutting-edge technology and positioning prosthodontists as the early-adopters of new technology in the dental community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信