Biomechanics of the implant-supported full arch fixed complete denture manufactured by milling and injection techniques: An experimental and FEA study.
Mustafa Gürkan, Ovul Kumbuloglu, Makbule Heval Şahan, Mert Narin, Halis Kandaş, Yusuf Arman, Hasan Yildiz, Mahmut Pekedis
{"title":"Biomechanics of the implant-supported full arch fixed complete denture manufactured by milling and injection techniques: An experimental and FEA study.","authors":"Mustafa Gürkan, Ovul Kumbuloglu, Makbule Heval Şahan, Mert Narin, Halis Kandaş, Yusuf Arman, Hasan Yildiz, Mahmut Pekedis","doi":"10.1111/jopr.14058","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aims to characterize the mechanical properties of implant-supported full arch fixed complete dentures manufactured by milling and injection techniques.</p><p><strong>Materials and methods: </strong>Twenty-two samples with milling and injection manufacturing techniques were fabricated. Twenty-two titanium samples were manufactured to be used as the control group. Additionally, eight PEEK samples from both the injection and milling groups were manufactured and tested using a uniaxial tensile test, and the obtained results were used as input data for finite element analysis (FEA). All-on-four PEEK hybrid prostheses supported with 2 implants on the mandible were used for the simulations. The FEA computations were performed for a bilateral 150 N force applied in both vertical and oblique directions.</p><p><strong>Results: </strong>A significant difference was observed between the injection and milled PEEK groups in terms of modulus of elasticity (Injection PEEK group: 3.1 ± 0.6 GPa, Milling PEEK: 4.6 ± 0.9 GPa) and flexural rigidity (Injection PEEK group: 28.0 ± 5.8 kNmm<sup>2</sup>, Milling PEEK: 41.2 ± 8.4 kNmm<sup>2</sup>) (p < 0.05), while no significant differences were observed between the injection and milled PEEK groups in terms of other parameters (p > 0.05). The finite element results showed that the highest stresses were observed in the Injection PEEK group, while the lowest were observed in the Milling Titanium group. Both injection and milled PEEK frameworks exceeded the yield stress limit during vertical and oblique loading.</p><p><strong>Conclusion: </strong>It was concluded that the forces implemented on rigid framework material such as titanium were better distributed to the implants supporting the all-on-four prosthesis.</p>","PeriodicalId":49152,"journal":{"name":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","volume":" ","pages":""},"PeriodicalIF":3.4000,"publicationDate":"2025-04-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jopr.14058","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: This study aims to characterize the mechanical properties of implant-supported full arch fixed complete dentures manufactured by milling and injection techniques.
Materials and methods: Twenty-two samples with milling and injection manufacturing techniques were fabricated. Twenty-two titanium samples were manufactured to be used as the control group. Additionally, eight PEEK samples from both the injection and milling groups were manufactured and tested using a uniaxial tensile test, and the obtained results were used as input data for finite element analysis (FEA). All-on-four PEEK hybrid prostheses supported with 2 implants on the mandible were used for the simulations. The FEA computations were performed for a bilateral 150 N force applied in both vertical and oblique directions.
Results: A significant difference was observed between the injection and milled PEEK groups in terms of modulus of elasticity (Injection PEEK group: 3.1 ± 0.6 GPa, Milling PEEK: 4.6 ± 0.9 GPa) and flexural rigidity (Injection PEEK group: 28.0 ± 5.8 kNmm2, Milling PEEK: 41.2 ± 8.4 kNmm2) (p < 0.05), while no significant differences were observed between the injection and milled PEEK groups in terms of other parameters (p > 0.05). The finite element results showed that the highest stresses were observed in the Injection PEEK group, while the lowest were observed in the Milling Titanium group. Both injection and milled PEEK frameworks exceeded the yield stress limit during vertical and oblique loading.
Conclusion: It was concluded that the forces implemented on rigid framework material such as titanium were better distributed to the implants supporting the all-on-four prosthesis.
期刊介绍:
The Journal of Prosthodontics promotes the advanced study and practice of prosthodontics, implant, esthetic, and reconstructive dentistry. It is the official journal of the American College of Prosthodontists, the American Dental Association-recognized voice of the Specialty of Prosthodontics. The journal publishes evidence-based original scientific articles presenting information that is relevant and useful to prosthodontists. Additionally, it publishes reports of innovative techniques, new instructional methodologies, and instructive clinical reports with an interdisciplinary flair. The journal is particularly focused on promoting the study and use of cutting-edge technology and positioning prosthodontists as the early-adopters of new technology in the dental community.