Role of Virtual Monoenergetic Images in the Assessment of Vessel Enhancement in Segmental Level in Third-Generation Dual-Source Dual-Energy CT Pulmonary Angiography-A Prospective Study.

IF 1 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Indian Journal of Radiology and Imaging Pub Date : 2024-09-03 eCollection Date: 2025-04-01 DOI:10.1055/s-0044-1788575
Vijayakumaran Ethiraju, Rajeshkumar Varatharajaperumal, Venkatesh Kasi Arunachalam, Abdulla KuruVambath, Rajesh Shanmugam Punniyakotti, Sriman Rajasekaran, Pankaj Mehta, Mathew Cherian
{"title":"Role of Virtual Monoenergetic Images in the Assessment of Vessel Enhancement in Segmental Level in Third-Generation Dual-Source Dual-Energy CT Pulmonary Angiography-A Prospective Study.","authors":"Vijayakumaran Ethiraju, Rajeshkumar Varatharajaperumal, Venkatesh Kasi Arunachalam, Abdulla KuruVambath, Rajesh Shanmugam Punniyakotti, Sriman Rajasekaran, Pankaj Mehta, Mathew Cherian","doi":"10.1055/s-0044-1788575","DOIUrl":null,"url":null,"abstract":"<p><p><b>Introduction</b>  Pulmonary embolism is the third most common cause of cardiovascular death worldwide and imaging plays a pivotal role in establishing the diagnosis. Computed tomography pulmonary angiography (CTPA) scores over other modalities and is the current diagnostic investigation of choice. In this study, we assessed the main pulmonary artery and its corresponding segmental artery attenuation in reconstructed virtual monoenergetic (mono plus) images (VMI-MP) and linear blended images (spectral post processing, SPP) obtained from dual-energy CTPA. The values were compared using contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR). <b>Materials and Methods</b>  Forty patients (mean age group, 53.6 years; 26 females and 14 males) with segmental pulmonary thromboembolism were included in this prospective study. The patients underwent CTPA study using bolus tracking in the dual-source CT-SOMATOM Force, Siemens. Postcontrast datasets (90 kV, 150 kV, and SPP) were used to reconstruct the monoenergetic images using syngo.via software virtually. Comparison was done between bivariate samples using the paired sample <i>t</i> -test. <b>Results</b>  The mean Hounsfield unit (HU) artery in the left lung for VMI-MP and SPP images were 886.9 ± 242 and 356.8 ± 121.3 HU, respectively. Similarly, for the right lung, it was 868.3 ± 243.5 and 336.1 ± 105.5 HU, respectively. The mean attenuation of the arteries in MP images was higher and statistically significant ( <i>p</i> -value <0.005). Likewise, the CNR) and SNR were found to have a statistically significant <i>p</i> -value (<0.005). An acceptable increase in image noise was seen in VMI as compared with SPP images. <b>Conclusion</b>  Low-keV VMIs perform more effectively than the conventional polyenergetic spectrum to evaluate vessel attenuation, which in turn increases thrombus detectability. The increased CNR in VMI enables improved lesion conspicuity.</p>","PeriodicalId":51597,"journal":{"name":"Indian Journal of Radiology and Imaging","volume":"35 2","pages":"254-262"},"PeriodicalIF":1.0000,"publicationDate":"2024-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12034417/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Radiology and Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0044-1788575","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/4/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction  Pulmonary embolism is the third most common cause of cardiovascular death worldwide and imaging plays a pivotal role in establishing the diagnosis. Computed tomography pulmonary angiography (CTPA) scores over other modalities and is the current diagnostic investigation of choice. In this study, we assessed the main pulmonary artery and its corresponding segmental artery attenuation in reconstructed virtual monoenergetic (mono plus) images (VMI-MP) and linear blended images (spectral post processing, SPP) obtained from dual-energy CTPA. The values were compared using contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR). Materials and Methods  Forty patients (mean age group, 53.6 years; 26 females and 14 males) with segmental pulmonary thromboembolism were included in this prospective study. The patients underwent CTPA study using bolus tracking in the dual-source CT-SOMATOM Force, Siemens. Postcontrast datasets (90 kV, 150 kV, and SPP) were used to reconstruct the monoenergetic images using syngo.via software virtually. Comparison was done between bivariate samples using the paired sample t -test. Results  The mean Hounsfield unit (HU) artery in the left lung for VMI-MP and SPP images were 886.9 ± 242 and 356.8 ± 121.3 HU, respectively. Similarly, for the right lung, it was 868.3 ± 243.5 and 336.1 ± 105.5 HU, respectively. The mean attenuation of the arteries in MP images was higher and statistically significant ( p -value <0.005). Likewise, the CNR) and SNR were found to have a statistically significant p -value (<0.005). An acceptable increase in image noise was seen in VMI as compared with SPP images. Conclusion  Low-keV VMIs perform more effectively than the conventional polyenergetic spectrum to evaluate vessel attenuation, which in turn increases thrombus detectability. The increased CNR in VMI enables improved lesion conspicuity.

Abstract Image

Abstract Image

Abstract Image

虚拟单能图像在第三代双源双能CT肺血管造影血管段水平增强评估中的作用——一项前瞻性研究。
肺栓塞是世界范围内第三大最常见的心血管死亡原因,影像学检查在确定诊断中起着关键作用。计算机断层肺血管造影(CTPA)评分高于其他模式,是目前诊断调查的选择。在这项研究中,我们评估了双能CTPA获得的重建虚拟单能(mono plus)图像(VMI-MP)和线性混合图像(光谱后处理,SPP)中的肺动脉主动脉及其相应的节段动脉衰减。采用对比噪声比(CNR)和信噪比(SNR)对数值进行比较。材料与方法40例患者(平均年龄53.6岁;26名女性和14名男性)患有节段性肺血栓栓塞纳入了这项前瞻性研究。患者采用双源CT-SOMATOM Force, Siemens进行CTPA研究。对比后数据集(90 kV, 150 kV和SPP)使用syngo重建单能图像。实际上是通过软件。双变量样本间的比较采用配对样本t检验。结果VMI-MP和SPP图像左肺平均Hounsfield单位(HU)分别为886.9±242和356.8±121.3 HU。同样,右肺分别为868.3±243.5和336.1±105.5 HU。结论低频率vmi比常规多能谱更有效地评估血管衰减,从而提高血栓的可检出性。VMI中CNR的增加使病变的显著性得到改善。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Indian Journal of Radiology and Imaging
Indian Journal of Radiology and Imaging RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
1.20
自引率
0.00%
发文量
115
审稿时长
45 weeks
期刊介绍: Information not localized
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信