Augmented reality system for endoscopic pituitary surgery with automatic registration.

IF 2.3 3区 医学 Q3 ENGINEERING, BIOMEDICAL
Aure Enkaoua, João Ramalhinho, Mobarakol Islam, Hani J Marcus, Matthew J Clarkson
{"title":"Augmented reality system for endoscopic pituitary surgery with automatic registration.","authors":"Aure Enkaoua, João Ramalhinho, Mobarakol Islam, Hani J Marcus, Matthew J Clarkson","doi":"10.1007/s11548-025-03384-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Endoscopic pituitary surgery is a minimally invasive technique to remove pituitary tumours through the nose. Currently, image guidance may be used in the form of a tracked pointer to help surgeons navigate the region and avoid damage to critical structures. However, the pointer method is mentally demanding as the pointer location is displayed in a different modality and disrupts the surgical workflow due to the setup time and frequent tool removal.</p><p><strong>Methods: </strong>We propose an Augmented Reality (AR) system where information from the pre-operative scan is displayed directly onto the endoscopic video. Our system features an on-board tracking system, allowing for the registration process to be performed automatically.</p><p><strong>Results: </strong>We evaluated the accuracy of our system and compared it to an AR system that uses an infrared (IR) camera to track an endoscope with reflective markers. Our system gave an accuracy of 1.1 (± 0.4) mm, compared to 2.4 (± 0.9) mm in the IR-tracked endoscope approach.</p><p><strong>Conclusion: </strong>Our Augmented Reality system is a more compact and transportable setup which outperformed the IR-tracked endoscope. The automatic registration method can save time in the operating room as well as increase AR overlay accuracy, improving the translation of these technologies.</p>","PeriodicalId":51251,"journal":{"name":"International Journal of Computer Assisted Radiology and Surgery","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2025-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Computer Assisted Radiology and Surgery","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s11548-025-03384-3","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Endoscopic pituitary surgery is a minimally invasive technique to remove pituitary tumours through the nose. Currently, image guidance may be used in the form of a tracked pointer to help surgeons navigate the region and avoid damage to critical structures. However, the pointer method is mentally demanding as the pointer location is displayed in a different modality and disrupts the surgical workflow due to the setup time and frequent tool removal.

Methods: We propose an Augmented Reality (AR) system where information from the pre-operative scan is displayed directly onto the endoscopic video. Our system features an on-board tracking system, allowing for the registration process to be performed automatically.

Results: We evaluated the accuracy of our system and compared it to an AR system that uses an infrared (IR) camera to track an endoscope with reflective markers. Our system gave an accuracy of 1.1 (± 0.4) mm, compared to 2.4 (± 0.9) mm in the IR-tracked endoscope approach.

Conclusion: Our Augmented Reality system is a more compact and transportable setup which outperformed the IR-tracked endoscope. The automatic registration method can save time in the operating room as well as increase AR overlay accuracy, improving the translation of these technologies.

具有自动注册的内窥镜垂体手术增强现实系统。
目的:垂体内窥镜手术是一种经鼻切除垂体肿瘤的微创技术。目前,图像引导可能以跟踪指针的形式使用,以帮助外科医生导航该区域并避免损伤关键结构。然而,指针法在精神上要求很高,因为指针位置以不同的方式显示,并且由于设置时间和频繁的工具移除而扰乱了手术工作流程。方法:我们提出一种增强现实(AR)系统,其中术前扫描的信息直接显示在内窥镜视频上。我们的系统具有机载跟踪系统,允许自动执行注册过程。结果:我们评估了系统的准确性,并将其与使用红外(IR)相机跟踪带有反射标记的内窥镜的AR系统进行了比较。我们的系统提供了1.1(±0.4)mm的精度,而红外跟踪内窥镜方法的精度为2.4(±0.9)mm。结论:我们的增强现实系统是一个更紧凑和便携的装置,优于红外跟踪内窥镜。自动配准方法可以节省手术室的时间,提高AR叠加精度,提高这些技术的翻译效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Computer Assisted Radiology and Surgery
International Journal of Computer Assisted Radiology and Surgery ENGINEERING, BIOMEDICAL-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
5.90
自引率
6.70%
发文量
243
审稿时长
6-12 weeks
期刊介绍: The International Journal for Computer Assisted Radiology and Surgery (IJCARS) is a peer-reviewed journal that provides a platform for closing the gap between medical and technical disciplines, and encourages interdisciplinary research and development activities in an international environment.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信