Impact of High Insertion Torque on Pain: A Randomized Split-Mouth Clinical Trial.

Mehmet Gümüş Kanmaz, Serhat Çinarcik
{"title":"Impact of High Insertion Torque on Pain: A Randomized Split-Mouth Clinical Trial.","authors":"Mehmet Gümüş Kanmaz, Serhat Çinarcik","doi":"10.1563/aaid-joi-D-25-00033","DOIUrl":null,"url":null,"abstract":"<p><p>During and after implant surgery, pain is one of the most frequent complaints, and its intensity is thought to be influenced by a variety of factors. This study aimed to examine the association between insertion torque values and patients' pain levels measured with the visual analog scale and investigate the relationship between insertion torque, implant stability quotient, and periotest values. This study was designed as a randomized, controlled, split-mouth clinical trial. Fifteen patients with bilateral single tooth loss in the posterior mandible were included. A total of 30 implants were randomly placed with high insertion torque (≥ 50 Ncm) on one side and regular insertion torque (<50 Ncm) on the other side in the same operation. The insertion torque, implant stability quotient, periotest values, and preoperative anxiety and postoperative pain levels were recorded. Mean insertion torque values for high and regular insertion torque groups were 77.27±5.77 Ncm and 30.47±8.33 Ncm, respectively. Pain levels were higher in the high insertion torque group than the regular insertion torque group on the operation day (p=0.016) and the following day (p=0.007). Furthermore, correlations were observed between insertion torque, implant stability quotient, and periotest values (p < 0.05). The study found that implants placed with high insertion torque had higher reported pain levels on the day of the operation and the following day.</p>","PeriodicalId":519890,"journal":{"name":"The Journal of oral implantology","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of oral implantology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1563/aaid-joi-D-25-00033","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

During and after implant surgery, pain is one of the most frequent complaints, and its intensity is thought to be influenced by a variety of factors. This study aimed to examine the association between insertion torque values and patients' pain levels measured with the visual analog scale and investigate the relationship between insertion torque, implant stability quotient, and periotest values. This study was designed as a randomized, controlled, split-mouth clinical trial. Fifteen patients with bilateral single tooth loss in the posterior mandible were included. A total of 30 implants were randomly placed with high insertion torque (≥ 50 Ncm) on one side and regular insertion torque (<50 Ncm) on the other side in the same operation. The insertion torque, implant stability quotient, periotest values, and preoperative anxiety and postoperative pain levels were recorded. Mean insertion torque values for high and regular insertion torque groups were 77.27±5.77 Ncm and 30.47±8.33 Ncm, respectively. Pain levels were higher in the high insertion torque group than the regular insertion torque group on the operation day (p=0.016) and the following day (p=0.007). Furthermore, correlations were observed between insertion torque, implant stability quotient, and periotest values (p < 0.05). The study found that implants placed with high insertion torque had higher reported pain levels on the day of the operation and the following day.

高插入扭矩对疼痛的影响:一项随机裂口临床试验。
在种植体手术期间和之后,疼痛是最常见的主诉之一,其强度被认为受多种因素的影响。本研究旨在探讨植入扭矩值与患者疼痛水平之间的关系,并探讨植入扭矩、种植体稳定商和骨膜值之间的关系。本研究设计为随机、对照、裂口临床试验。研究对象为15例双侧后下颌单牙缺失患者。随机放置30个种植体,一侧置入高扭矩(≥50 Ncm),一侧置入规则扭矩(
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信