{"title":"Optical Characterization of Parasitic Motion in a Long-Stroke Shaker.","authors":"Jared H Strait, Richard A Allen","doi":"10.1088/1681-7575/ad90e6","DOIUrl":null,"url":null,"abstract":"<p><p>We present an optical scheme to simultaneously characterize the cross-axis and rotational parasitic motions of a long-stroke shaker. By leveraging the geometric properties of a corner cube retroreflector mounted on the shaker load table, we independently sample pitch, yaw, and horizontal and vertical displacements with sampling rates above 10 kHz. We have applied our optical apparatus to a 400-mm-stroke shaker operated from 0.1 Hz to 100 Hz and present two forms of analysis: (A) Frequency-domain data for the four measured parasitic degrees of freedom, with the resulting implications for accelerometer calibration uncertainties, and (B) extracted trajectories of the shaker table, allowing visualization of the bowed linear guide below 0.5 Hz and higher harmonics and hysteresis above 10 Hz. Our findings demonstrate our optical measurement scheme to be an effective tool for the characterization of parasitic motion for long-stroke shakers. As an example, we determine the \"gravity error\" in accelerometer calibration with our shaker to be (1.3 ± 0.1) % times the acceleration amplitude at 0.1 Hz, providing a correction to reduce uncertainty from this effect by an order of magnitude.</p>","PeriodicalId":18444,"journal":{"name":"Metrologia","volume":"62 1","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12013252/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Metrologia","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1681-7575/ad90e6","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0
Abstract
We present an optical scheme to simultaneously characterize the cross-axis and rotational parasitic motions of a long-stroke shaker. By leveraging the geometric properties of a corner cube retroreflector mounted on the shaker load table, we independently sample pitch, yaw, and horizontal and vertical displacements with sampling rates above 10 kHz. We have applied our optical apparatus to a 400-mm-stroke shaker operated from 0.1 Hz to 100 Hz and present two forms of analysis: (A) Frequency-domain data for the four measured parasitic degrees of freedom, with the resulting implications for accelerometer calibration uncertainties, and (B) extracted trajectories of the shaker table, allowing visualization of the bowed linear guide below 0.5 Hz and higher harmonics and hysteresis above 10 Hz. Our findings demonstrate our optical measurement scheme to be an effective tool for the characterization of parasitic motion for long-stroke shakers. As an example, we determine the "gravity error" in accelerometer calibration with our shaker to be (1.3 ± 0.1) % times the acceleration amplitude at 0.1 Hz, providing a correction to reduce uncertainty from this effect by an order of magnitude.
期刊介绍:
Published 6 times per year, Metrologia covers the fundamentals of measurements, particularly those dealing with the seven base units of the International System of Units (metre, kilogram, second, ampere, kelvin, candela, mole) or proposals to replace them.
The journal also publishes papers that contribute to the solution of difficult measurement problems and improve the accuracy of derived units and constants that are of fundamental importance to physics.
In addition to regular papers, the journal publishes review articles, issues devoted to single topics of timely interest and occasional conference proceedings. Letters to the Editor and Short Communications (generally three pages or less) are also considered.