Bilirubin Elevation Associated With Pulsed Field Ablation Induced Hemolysis in Patients With Paroxysmal Atrial Fibrillation.

IF 2.3 3区 医学 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Fengqi Xuan, Mingying Ding, Ming Liang, Huimin Chu, Jing Xu, Zhiqing Jin, Jian Ding, Mingyu Sun, Wei Ma, Zulu Wang
{"title":"Bilirubin Elevation Associated With Pulsed Field Ablation Induced Hemolysis in Patients With Paroxysmal Atrial Fibrillation.","authors":"Fengqi Xuan, Mingying Ding, Ming Liang, Huimin Chu, Jing Xu, Zhiqing Jin, Jian Ding, Mingyu Sun, Wei Ma, Zulu Wang","doi":"10.1111/jce.16664","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and aims: </strong>Hemolysis-related renal failure after pulsed field ablation (PFA) has been described in recently published cases, we reported the incidence of bilirubin elevation after PFA utilizing a novel hexaspline PFA catheter.</p><p><strong>Methods: </strong>PFA was performed in patients with paroxysmal atrial fibrillation using novel hexaspline PFA catheter, and serum bilirubin, hemoglobin and renal function were measured at baseline and the next day post ablation.</p><p><strong>Results: </strong>A total of 94 patients were analyzed, and 30 of 94 (31.9%) patients had obvious total bilirubin elevation the next day post PFA. In the 30 patients, 26 (86.7%) patients had a predominantly indirect hyperbilirubinemia, suggesting a likely presence of PFA-induced hemolysis. The liver enzyme contents post ablation were normal in all patients and no signs of hemolytic anemia and renal function injury were detected. The impact factors associated with indrect hyperbilirubinemia were also analyzed and higher number of applications tented to produce PFA-induced hemolysis. More than 86.5 applications seem to have a better sensivity and specificity to predict hemolysis.</p><p><strong>Conclusion: </strong>Intravascular hemolysis can occur after utilizing novel hexaspline catheter, but the severity of hemolysis was mild and temporary. The number of applications appears to be a determining factor leading to hemolysis.</p>","PeriodicalId":15178,"journal":{"name":"Journal of Cardiovascular Electrophysiology","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2025-04-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jce.16664","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background and aims: Hemolysis-related renal failure after pulsed field ablation (PFA) has been described in recently published cases, we reported the incidence of bilirubin elevation after PFA utilizing a novel hexaspline PFA catheter.

Methods: PFA was performed in patients with paroxysmal atrial fibrillation using novel hexaspline PFA catheter, and serum bilirubin, hemoglobin and renal function were measured at baseline and the next day post ablation.

Results: A total of 94 patients were analyzed, and 30 of 94 (31.9%) patients had obvious total bilirubin elevation the next day post PFA. In the 30 patients, 26 (86.7%) patients had a predominantly indirect hyperbilirubinemia, suggesting a likely presence of PFA-induced hemolysis. The liver enzyme contents post ablation were normal in all patients and no signs of hemolytic anemia and renal function injury were detected. The impact factors associated with indrect hyperbilirubinemia were also analyzed and higher number of applications tented to produce PFA-induced hemolysis. More than 86.5 applications seem to have a better sensivity and specificity to predict hemolysis.

Conclusion: Intravascular hemolysis can occur after utilizing novel hexaspline catheter, but the severity of hemolysis was mild and temporary. The number of applications appears to be a determining factor leading to hemolysis.

阵发性心房颤动患者胆红素升高与脉冲场消融引起的溶血相关。
背景和目的:在最近发表的病例中描述了脉冲场消融(PFA)后溶血相关肾衰竭,我们报道了使用新型六线PFA导管进行脉冲场消融后胆红素升高的发生率。方法:对阵发性心房颤动患者采用新型六品PFA导管进行PFA治疗,并在消融后基线和次日测定血清胆红素、血红蛋白和肾功能。结果:共分析94例患者,其中30例(31.9%)患者PFA后次日总胆红素明显升高。在30例患者中,26例(86.7%)患者主要为间接高胆红素血症,提示可能存在pfa诱导的溶血。所有患者消融后肝酶含量正常,未发现溶血性贫血和肾功能损伤的迹象。与间接高胆红素血症相关的影响因素也被分析,更多的应用倾向于产生pfa诱导的溶血。86.5以上的应用似乎对预测溶血有更好的敏感性和特异性。结论:应用新型六斜线导管后可发生血管内溶血,但溶血的严重程度为轻度和暂时性的。应用的数量似乎是导致溶血的决定性因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.20
自引率
14.80%
发文量
433
审稿时长
3-6 weeks
期刊介绍: Journal of Cardiovascular Electrophysiology (JCE) keeps its readership well informed of the latest developments in the study and management of arrhythmic disorders. Edited by Bradley P. Knight, M.D., and a distinguished international editorial board, JCE is the leading journal devoted to the study of the electrophysiology of the heart.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信