Accuracy of FreeStyle Libre 3 During Moderate-Intensity Continuous Aerobic Exercise at Different Phases of the Menstrual Cycle in Females with Type 1 Diabetes.

IF 6.3 2区 医学 Q1 ENDOCRINOLOGY & METABOLISM
Diabetes technology & therapeutics Pub Date : 2025-09-01 Epub Date: 2025-04-17 DOI:10.1089/dia.2024.0558
Alba Cuerda-Del Pino, Alejandro José Laguna Sanz, José-Luis Díez, Paolo Rossetti, Cynthia Marco Romero, F Javier Ampudia-Blasco, Jorge Bondia, Rodrigo Martín-San Agustín
{"title":"Accuracy of FreeStyle Libre 3 During Moderate-Intensity Continuous Aerobic Exercise at Different Phases of the Menstrual Cycle in Females with Type 1 Diabetes.","authors":"Alba Cuerda-Del Pino, Alejandro José Laguna Sanz, José-Luis Díez, Paolo Rossetti, Cynthia Marco Romero, F Javier Ampudia-Blasco, Jorge Bondia, Rodrigo Martín-San Agustín","doi":"10.1089/dia.2024.0558","DOIUrl":null,"url":null,"abstract":"<p><p><b><i>Background:</i></b> The use of continuous glucose monitoring (CGM) devices in managing type 1 diabetes (T1D) has been associated with improved glycemic control in individuals with T1D. A key challenge for CGMs, however, is achieving accuracy, particularly under conditions where glucose levels may fluctuate rapidly, such as during exercise. Another factor contributing to blood glucose variability is the menstrual cycle, during which hormonal fluctuations affect insulin sensitivity, leading to variable glucose levels. This study aimed to assess the accuracy of FreeStyle Libre-3 (FSL3) during continuous moderate-intensity aerobic exercise (CONT) performed in the follicular and luteal phases of the menstrual cycle in females with T1D. <b><i>Methods:</i></b> Participants underwent CONT sessions on a cycle ergometer, one in the follicular phase and one in the luteal phase of the menstrual cycle, at the Research Laboratory of the Faculty of Physiotherapy. Glucose levels were measured every 10 min using FSL3 and the YSI 2500 as a gold standard. Measurements began 20 min before CONT and continued for 20 min after exercise. <b><i>Results:</i></b> A total of 26 females (mean age 32.2 ± 6.1 years and mean duration of diabetes 16.4 ± 8.4 years) participated in this study. FSL3 showed significant differences compared with YSI glucose data for both phases of the menstrual cycle (about 16 mg/dL higher in FSL3). There were no differences in mean absolute relative differences (MARDs) between the follicular (16.06%) and luteal (16.43) phases. Moreover, exercise did not affect MARDs, which were 14.21% pre-exercise and 17.63% postexercise for the follicular phase and 14.95% pre-exercise and 17.71% postexercise for the luteal phase. <b><i>Conclusions:</i></b> The findings suggest that the accuracy of FSL3 is not affected by CONT, showing good accuracy levels in both phases of the menstrual cycle. Thus, this study is the first to examine the influence of the menstrual cycle and exercise on the accuracy of a CGM device. The study was also prospectively registered at clinicaltrials.gov (NCT06086067).</p>","PeriodicalId":11159,"journal":{"name":"Diabetes technology & therapeutics","volume":" ","pages":"687-695"},"PeriodicalIF":6.3000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetes technology & therapeutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/dia.2024.0558","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/4/17 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The use of continuous glucose monitoring (CGM) devices in managing type 1 diabetes (T1D) has been associated with improved glycemic control in individuals with T1D. A key challenge for CGMs, however, is achieving accuracy, particularly under conditions where glucose levels may fluctuate rapidly, such as during exercise. Another factor contributing to blood glucose variability is the menstrual cycle, during which hormonal fluctuations affect insulin sensitivity, leading to variable glucose levels. This study aimed to assess the accuracy of FreeStyle Libre-3 (FSL3) during continuous moderate-intensity aerobic exercise (CONT) performed in the follicular and luteal phases of the menstrual cycle in females with T1D. Methods: Participants underwent CONT sessions on a cycle ergometer, one in the follicular phase and one in the luteal phase of the menstrual cycle, at the Research Laboratory of the Faculty of Physiotherapy. Glucose levels were measured every 10 min using FSL3 and the YSI 2500 as a gold standard. Measurements began 20 min before CONT and continued for 20 min after exercise. Results: A total of 26 females (mean age 32.2 ± 6.1 years and mean duration of diabetes 16.4 ± 8.4 years) participated in this study. FSL3 showed significant differences compared with YSI glucose data for both phases of the menstrual cycle (about 16 mg/dL higher in FSL3). There were no differences in mean absolute relative differences (MARDs) between the follicular (16.06%) and luteal (16.43) phases. Moreover, exercise did not affect MARDs, which were 14.21% pre-exercise and 17.63% postexercise for the follicular phase and 14.95% pre-exercise and 17.71% postexercise for the luteal phase. Conclusions: The findings suggest that the accuracy of FSL3 is not affected by CONT, showing good accuracy levels in both phases of the menstrual cycle. Thus, this study is the first to examine the influence of the menstrual cycle and exercise on the accuracy of a CGM device. The study was also prospectively registered at clinicaltrials.gov (NCT06086067).

1型糖尿病女性月经周期不同阶段中强度连续有氧运动自由泳自由泳3的准确性
背景:在治疗1型糖尿病(T1D)中使用连续血糖监测(CGM)设备与改善T1D患者的血糖控制有关。然而,cgm的一个关键挑战是实现准确性,特别是在葡萄糖水平可能快速波动的情况下,例如在运动期间。另一个导致血糖变化的因素是月经周期,在此期间荷尔蒙波动会影响胰岛素敏感性,导致血糖水平变化。本研究旨在评估自由式Libre-3 (FSL3)在T1D女性月经周期卵泡期和黄体期进行连续中等强度有氧运动(CONT)时的准确性。方法:在物理治疗学院的研究实验室,参与者在月经周期的卵泡期和黄体期分别进行周期测功仪上的CONT。以FSL3和YSI 2500为金标准,每10分钟测量一次血糖水平。测量开始于CONT前20分钟,并持续到运动后20分钟。结果:女性26例,平均年龄32.2±6.1岁,平均糖尿病病程16.4±8.4年。在月经周期的两个阶段,FSL3与YSI血糖数据有显著差异(FSL3比YSI高约16 mg/dL)。卵泡期(16.06%)和黄体期(16.43%)的平均绝对相对差异(mard)无差异。此外,运动不影响MARDs,滤泡期运动前为14.21%,运动后为17.63%,黄体期运动前为14.95%,运动后为17.71%。结论:研究结果表明,FSL3的准确性不受CONT的影响,在月经周期的两个阶段都显示出良好的准确性水平。因此,本研究首次探讨了月经周期和运动对CGM装置准确性的影响。该研究还在clinicaltrials.gov (NCT06086067)进行了前瞻性注册。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Diabetes technology & therapeutics
Diabetes technology & therapeutics 医学-内分泌学与代谢
CiteScore
10.60
自引率
14.80%
发文量
145
审稿时长
3-8 weeks
期刊介绍: Diabetes Technology & Therapeutics is the only peer-reviewed journal providing healthcare professionals with information on new devices, drugs, drug delivery systems, and software for managing patients with diabetes. This leading international journal delivers practical information and comprehensive coverage of cutting-edge technologies and therapeutics in the field, and each issue highlights new pharmacological and device developments to optimize patient care.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信