{"title":"Assessment of serum free light chain measurements in a large Chinese chronic kidney disease cohort: a multicenter real-world study.","authors":"Xia Luo, Xiaomeng Zhang, Xu Yuan, Pan Zhao, Wenqian Zhang, Lingyan Deng, Liming Cheng","doi":"10.1515/cclm-2024-1226","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Diagnosing monoclonal gammopathy in chronic kidney disease (CKD) patients is challenging due to the complex interpretation of serum free light chain (FLC) levels. This study aimed to assess the FLC levels in a large cohort of Chinese CKD patients.</p><p><strong>Methods: </strong>We enrolled 5,287 patients with all-cause nondialysis CKD from three medical centers between February 2018 and April 2023. Central 95 % reference ranges were established using data from one center and validated in an independent subpopulation from the other two centers. The crude prevalence of light chain monoclonal gammopathy of undetermined significance (LC-MGUS) was assessed against established norms for the entire cohort and subgroups based on estimated glomerular filtration rate (eGFR).</p><p><strong>Results: </strong>A notable proportion of patients exceeded the standard reference limits for kappa (89.0 %), lambda (72.1 %), and FLC ratio (10.5 %), whereas non-eGFR-based renal reference interval identified only 0.3 % with abnormal FLC ratios. The iStopMM reference ranges showed higher out-of-range rates for absolute FLC levels in patients with preserved kidney function and lower rates in those with impaired kidney function, while the FLC ratio references remained robust across all groups. The crude prevalence of LC-MGUS was 10.4 % using standard ranges, predominantly kappa LC-MGUS (99.8 %). This prevalence decreased to 0.3 % with non-eGFR-based renal reference interval and 0.5 % with the iStopMM ranges. Using the newly established reference ranges, the crude prevalence was found to be 0.9 %.</p><p><strong>Conclusions: </strong>Our findings suggest that current FLC reference ranges are inadequate for the Chinese population, underscoring the need for eGFR-based reference ranges tailored to this demographic.</p>","PeriodicalId":10390,"journal":{"name":"Clinical chemistry and laboratory medicine","volume":" ","pages":""},"PeriodicalIF":3.8000,"publicationDate":"2025-04-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical chemistry and laboratory medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1515/cclm-2024-1226","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: Diagnosing monoclonal gammopathy in chronic kidney disease (CKD) patients is challenging due to the complex interpretation of serum free light chain (FLC) levels. This study aimed to assess the FLC levels in a large cohort of Chinese CKD patients.
Methods: We enrolled 5,287 patients with all-cause nondialysis CKD from three medical centers between February 2018 and April 2023. Central 95 % reference ranges were established using data from one center and validated in an independent subpopulation from the other two centers. The crude prevalence of light chain monoclonal gammopathy of undetermined significance (LC-MGUS) was assessed against established norms for the entire cohort and subgroups based on estimated glomerular filtration rate (eGFR).
Results: A notable proportion of patients exceeded the standard reference limits for kappa (89.0 %), lambda (72.1 %), and FLC ratio (10.5 %), whereas non-eGFR-based renal reference interval identified only 0.3 % with abnormal FLC ratios. The iStopMM reference ranges showed higher out-of-range rates for absolute FLC levels in patients with preserved kidney function and lower rates in those with impaired kidney function, while the FLC ratio references remained robust across all groups. The crude prevalence of LC-MGUS was 10.4 % using standard ranges, predominantly kappa LC-MGUS (99.8 %). This prevalence decreased to 0.3 % with non-eGFR-based renal reference interval and 0.5 % with the iStopMM ranges. Using the newly established reference ranges, the crude prevalence was found to be 0.9 %.
Conclusions: Our findings suggest that current FLC reference ranges are inadequate for the Chinese population, underscoring the need for eGFR-based reference ranges tailored to this demographic.
期刊介绍:
Clinical Chemistry and Laboratory Medicine (CCLM) publishes articles on novel teaching and training methods applicable to laboratory medicine. CCLM welcomes contributions on the progress in fundamental and applied research and cutting-edge clinical laboratory medicine. It is one of the leading journals in the field, with an impact factor over 3. CCLM is issued monthly, and it is published in print and electronically.
CCLM is the official journal of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) and publishes regularly EFLM recommendations and news. CCLM is the official journal of the National Societies from Austria (ÖGLMKC); Belgium (RBSLM); Germany (DGKL); Hungary (MLDT); Ireland (ACBI); Italy (SIBioC); Portugal (SPML); and Slovenia (SZKK); and it is affiliated to AACB (Australia) and SFBC (France).
Topics:
- clinical biochemistry
- clinical genomics and molecular biology
- clinical haematology and coagulation
- clinical immunology and autoimmunity
- clinical microbiology
- drug monitoring and analysis
- evaluation of diagnostic biomarkers
- disease-oriented topics (cardiovascular disease, cancer diagnostics, diabetes)
- new reagents, instrumentation and technologies
- new methodologies
- reference materials and methods
- reference values and decision limits
- quality and safety in laboratory medicine
- translational laboratory medicine
- clinical metrology
Follow @cclm_degruyter on Twitter!