Cinzia Auriti, Domenico Umberto De Rose, Chiara Maddaloni, Lucilla Ravà, Ludovica Martini, Eleonora Di Tommaso, Paola Bernaschi, Emanuel Paionni, Ottavia Porzio, Fiammetta Piersigilli, Marco Iannetta, Andrea Dotta, Maria Paola Ronchetti
{"title":"The accuracy of presepsin in diagnosing neonatal late-onset sepsis in critically ill neonates: a prospective study.","authors":"Cinzia Auriti, Domenico Umberto De Rose, Chiara Maddaloni, Lucilla Ravà, Ludovica Martini, Eleonora Di Tommaso, Paola Bernaschi, Emanuel Paionni, Ottavia Porzio, Fiammetta Piersigilli, Marco Iannetta, Andrea Dotta, Maria Paola Ronchetti","doi":"10.1515/cclm-2025-0128","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The diagnostic accuracy of presepsin (P-SEP) in the newborn is still under evaluation.</p><p><strong>Methods: </strong>In a multicenter study, we studied the accuracy of P-SEP as a diagnostic marker of late-onset sepsis (LOS) in critical newborns with underlying disorders, to define the most accurate cut-off to distinguish infected from uninfected patients.</p><p><strong>Results: </strong>Sixty-nine/351 newborns without infections at admission developed LOS. The median P-SEP value at T0 (admission) was 518.0 ng/L (IQR 313.0-789.0), without significant differences related to underlying diseases (p=0.52). In neonates who developed LOS, P-SEP increased at the onset of infection (T1) (median: 816.0 ng/L) and after 24-48 h (median: 901.0 ng/L) compared with their value at admission (median: 560.0 ng/L) (p<0.01 and p=0.03, respectively). The area under the ROC curve at T1 was 0.71 (95 % CI 0.65-0.78) when all cases of sepsis were included in the analysis and increased to 0.74 (95 % CI 0.66-0.81) considering only confirmed sepsis. Approximately two-thirds of patients were correctly classified, setting the cut-off at 713 ng/L, with a negative predictive value of 89.0 %.</p><p><strong>Conclusions: </strong>At a cut-off of 713 ng/L, P-SEP has good accuracy in diagnosing LOS in critically ill newborns. In uninfected newborns, the median value of P-SEP is not influenced by any underlying pathology.</p>","PeriodicalId":10390,"journal":{"name":"Clinical chemistry and laboratory medicine","volume":" ","pages":""},"PeriodicalIF":3.8000,"publicationDate":"2025-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical chemistry and laboratory medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1515/cclm-2025-0128","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: The diagnostic accuracy of presepsin (P-SEP) in the newborn is still under evaluation.
Methods: In a multicenter study, we studied the accuracy of P-SEP as a diagnostic marker of late-onset sepsis (LOS) in critical newborns with underlying disorders, to define the most accurate cut-off to distinguish infected from uninfected patients.
Results: Sixty-nine/351 newborns without infections at admission developed LOS. The median P-SEP value at T0 (admission) was 518.0 ng/L (IQR 313.0-789.0), without significant differences related to underlying diseases (p=0.52). In neonates who developed LOS, P-SEP increased at the onset of infection (T1) (median: 816.0 ng/L) and after 24-48 h (median: 901.0 ng/L) compared with their value at admission (median: 560.0 ng/L) (p<0.01 and p=0.03, respectively). The area under the ROC curve at T1 was 0.71 (95 % CI 0.65-0.78) when all cases of sepsis were included in the analysis and increased to 0.74 (95 % CI 0.66-0.81) considering only confirmed sepsis. Approximately two-thirds of patients were correctly classified, setting the cut-off at 713 ng/L, with a negative predictive value of 89.0 %.
Conclusions: At a cut-off of 713 ng/L, P-SEP has good accuracy in diagnosing LOS in critically ill newborns. In uninfected newborns, the median value of P-SEP is not influenced by any underlying pathology.
期刊介绍:
Clinical Chemistry and Laboratory Medicine (CCLM) publishes articles on novel teaching and training methods applicable to laboratory medicine. CCLM welcomes contributions on the progress in fundamental and applied research and cutting-edge clinical laboratory medicine. It is one of the leading journals in the field, with an impact factor over 3. CCLM is issued monthly, and it is published in print and electronically.
CCLM is the official journal of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) and publishes regularly EFLM recommendations and news. CCLM is the official journal of the National Societies from Austria (ÖGLMKC); Belgium (RBSLM); Germany (DGKL); Hungary (MLDT); Ireland (ACBI); Italy (SIBioC); Portugal (SPML); and Slovenia (SZKK); and it is affiliated to AACB (Australia) and SFBC (France).
Topics:
- clinical biochemistry
- clinical genomics and molecular biology
- clinical haematology and coagulation
- clinical immunology and autoimmunity
- clinical microbiology
- drug monitoring and analysis
- evaluation of diagnostic biomarkers
- disease-oriented topics (cardiovascular disease, cancer diagnostics, diabetes)
- new reagents, instrumentation and technologies
- new methodologies
- reference materials and methods
- reference values and decision limits
- quality and safety in laboratory medicine
- translational laboratory medicine
- clinical metrology
Follow @cclm_degruyter on Twitter!