Peter Doyle , Jacob Gorton , Kara Godsey , Annabelle Le Coq , Jason Harp , Matthew Jones , Stephanie Curlin , Andrew Nelson
{"title":"Swelling and Fission Gas Release of U-10Mo and U-17Mo Following Neutron Irradiation at 250 – 500°C","authors":"Peter Doyle , Jacob Gorton , Kara Godsey , Annabelle Le Coq , Jason Harp , Matthew Jones , Stephanie Curlin , Andrew Nelson","doi":"10.1016/j.jnucmat.2025.155851","DOIUrl":null,"url":null,"abstract":"<div><div>The performance of metallic fuel alloys, U-10Mo and U-17Mo, was examined using the MiniFuel test system in the High Flux Isotope Reactor. Approximately 0.8 mm thick disks were irradiated at target temperatures of 250°C, 350°C, 450°C, and 500°C up to three different fission densities, culminating at a maximum fission density of 6.8×10<sup>20</sup> cm<sup>−3</sup>. Fission rates decayed from 3 – 6 × 10<sup>13</sup> cm<sup>−3</sup>s<sup>−1</sup> to 2 – 4 × 10<sup>13</sup> cm<sup>−3</sup>s<sup>−1</sup> over the course of the longest, eight cycle, irradiation as the <sup>235</sup>U was consumed and the <sup>239</sup>Pu concentration accumulated. Actual irradiation temperature on the last day of irradiation was measured via dilatometry using the SiC passive thermometry recovered from the MiniFuel subcapsules and compared favorably with the thermal calculations using as-built geometry and test conditions. Furthermore, average simulated temperatures were within 50°C of the target temperatures, except for the 500°C irradiation, for which the temperature variation was 62°C, 32°C, and 90°C in the in two, four, and eight cycle irradiations, respectively. Fission gas release (FGR) measurements showed no release above recoil for any U-17Mo fuels or for the U-10Mo fuel irradiated at 250°C. Significant (40%–80%) FGR was found for the medium- to highest-burnup U-10Mo samples irradiated at target temperatures 350°C–500°C. Significant FGR correlated with sample thickness swelling, which was as high as 13%–35% for high-release samples and below 7% for all other (low–gas release) samples.</div></div>","PeriodicalId":373,"journal":{"name":"Journal of Nuclear Materials","volume":"612 ","pages":"Article 155851"},"PeriodicalIF":2.8000,"publicationDate":"2025-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Nuclear Materials","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022311525002454","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
The performance of metallic fuel alloys, U-10Mo and U-17Mo, was examined using the MiniFuel test system in the High Flux Isotope Reactor. Approximately 0.8 mm thick disks were irradiated at target temperatures of 250°C, 350°C, 450°C, and 500°C up to three different fission densities, culminating at a maximum fission density of 6.8×1020 cm−3. Fission rates decayed from 3 – 6 × 1013 cm−3s−1 to 2 – 4 × 1013 cm−3s−1 over the course of the longest, eight cycle, irradiation as the 235U was consumed and the 239Pu concentration accumulated. Actual irradiation temperature on the last day of irradiation was measured via dilatometry using the SiC passive thermometry recovered from the MiniFuel subcapsules and compared favorably with the thermal calculations using as-built geometry and test conditions. Furthermore, average simulated temperatures were within 50°C of the target temperatures, except for the 500°C irradiation, for which the temperature variation was 62°C, 32°C, and 90°C in the in two, four, and eight cycle irradiations, respectively. Fission gas release (FGR) measurements showed no release above recoil for any U-17Mo fuels or for the U-10Mo fuel irradiated at 250°C. Significant (40%–80%) FGR was found for the medium- to highest-burnup U-10Mo samples irradiated at target temperatures 350°C–500°C. Significant FGR correlated with sample thickness swelling, which was as high as 13%–35% for high-release samples and below 7% for all other (low–gas release) samples.
期刊介绍:
The Journal of Nuclear Materials publishes high quality papers in materials research for nuclear applications, primarily fission reactors, fusion reactors, and similar environments including radiation areas of charged particle accelerators. Both original research and critical review papers covering experimental, theoretical, and computational aspects of either fundamental or applied nature are welcome.
The breadth of the field is such that a wide range of processes and properties in the field of materials science and engineering is of interest to the readership, spanning atom-scale processes, microstructures, thermodynamics, mechanical properties, physical properties, and corrosion, for example.
Topics covered by JNM
Fission reactor materials, including fuels, cladding, core structures, pressure vessels, coolant interactions with materials, moderator and control components, fission product behavior.
Materials aspects of the entire fuel cycle.
Materials aspects of the actinides and their compounds.
Performance of nuclear waste materials; materials aspects of the immobilization of wastes.
Fusion reactor materials, including first walls, blankets, insulators and magnets.
Neutron and charged particle radiation effects in materials, including defects, transmutations, microstructures, phase changes and macroscopic properties.
Interaction of plasmas, ion beams, electron beams and electromagnetic radiation with materials relevant to nuclear systems.