An upfront patient selection strategy based on personalized data-driven computed tomography generation for deep inspiration breath-hold in breast radiotherapy

IF 3.3 3区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Yunxiang Wang , Yihang Zhang , Si-Ye Chen , Tie Lv , Yuxiang Liu , Hui Fang , Hao Jing , Ning-Ning Lu , Yi-Rui Zhai , Yong-Wen Song , Yue-Ping Liu , Wen-Wen Zhang , Shu-Nan Qi , Yuan Tang , Bo Chen , Ye-Xiong Li , Kuo Men , Xinyuan Chen , Wei Zhao , Shu-Lian Wang
{"title":"An upfront patient selection strategy based on personalized data-driven computed tomography generation for deep inspiration breath-hold in breast radiotherapy","authors":"Yunxiang Wang ,&nbsp;Yihang Zhang ,&nbsp;Si-Ye Chen ,&nbsp;Tie Lv ,&nbsp;Yuxiang Liu ,&nbsp;Hui Fang ,&nbsp;Hao Jing ,&nbsp;Ning-Ning Lu ,&nbsp;Yi-Rui Zhai ,&nbsp;Yong-Wen Song ,&nbsp;Yue-Ping Liu ,&nbsp;Wen-Wen Zhang ,&nbsp;Shu-Nan Qi ,&nbsp;Yuan Tang ,&nbsp;Bo Chen ,&nbsp;Ye-Xiong Li ,&nbsp;Kuo Men ,&nbsp;Xinyuan Chen ,&nbsp;Wei Zhao ,&nbsp;Shu-Lian Wang","doi":"10.1016/j.ejmp.2025.104964","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Currently there is no widely used upfront selection method to determine whether patients are suitable for deep inspiration breath-hold (DIBH) in left-sided breast radiotherapy.</div></div><div><h3>Purpose</h3><div>To establish an upfront patient selection strategy to improve the decision-making efficiency of DIBH and avoid extra computed tomography (CT) exposure to patients.</div></div><div><h3>Methods</h3><div>A total of 174 patients who underwent both free-breathing (FB) and DIBH scans were enrolled. A general principal component analysis model for DIBH-CT synthesis was trained and consists of principal component feature vectors extracted from paired FB-CT and DIBH-CT in training set. The coefficients of the vectors were optimized to minimize the difference between synthetic CT and breath-hold scout image of each patient in test set, leading to personalized DIBH-CT synthesis. An upfront patient selection strategy was established based on cardiac dose in synthetic DIBH-CT plan. The performance of DIBH-CT synthesis was analyzed in terms of geometric and dosimetric consistency between synthetic and scanned DIBH-CTs. The accuracy of the patient selection strategy was evaluated. Time assumption of the patient selection workflow was analyzed.</div></div><div><h3>Results</h3><div>Synthetic DIBH-CTs had average Dice similarity coefficients of 0.84 for the heart and 0.91 for the lungs compared with scanned DIBH-CTs. Synthetic DIBH-CT plans revealed an average mean heart dose reduction of 1.46 Gy, which was not significantly different from 1.51 Gy in scanned DIBH-CT plans (p = 0.878). The patient selection strategy yielded the correct benefit results with accuracy of 86.7 %. The average time assumption for patient selection was 11.9 ± 3.6 min.</div></div><div><h3>Conclusions</h3><div>The proposed patient selection strategy can accurately identify patients benefiting from DIBH and provides a more efficient workflow for DIBH.</div></div>","PeriodicalId":56092,"journal":{"name":"Physica Medica-European Journal of Medical Physics","volume":"133 ","pages":"Article 104964"},"PeriodicalIF":3.3000,"publicationDate":"2025-04-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physica Medica-European Journal of Medical Physics","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1120179725000742","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Currently there is no widely used upfront selection method to determine whether patients are suitable for deep inspiration breath-hold (DIBH) in left-sided breast radiotherapy.

Purpose

To establish an upfront patient selection strategy to improve the decision-making efficiency of DIBH and avoid extra computed tomography (CT) exposure to patients.

Methods

A total of 174 patients who underwent both free-breathing (FB) and DIBH scans were enrolled. A general principal component analysis model for DIBH-CT synthesis was trained and consists of principal component feature vectors extracted from paired FB-CT and DIBH-CT in training set. The coefficients of the vectors were optimized to minimize the difference between synthetic CT and breath-hold scout image of each patient in test set, leading to personalized DIBH-CT synthesis. An upfront patient selection strategy was established based on cardiac dose in synthetic DIBH-CT plan. The performance of DIBH-CT synthesis was analyzed in terms of geometric and dosimetric consistency between synthetic and scanned DIBH-CTs. The accuracy of the patient selection strategy was evaluated. Time assumption of the patient selection workflow was analyzed.

Results

Synthetic DIBH-CTs had average Dice similarity coefficients of 0.84 for the heart and 0.91 for the lungs compared with scanned DIBH-CTs. Synthetic DIBH-CT plans revealed an average mean heart dose reduction of 1.46 Gy, which was not significantly different from 1.51 Gy in scanned DIBH-CT plans (p = 0.878). The patient selection strategy yielded the correct benefit results with accuracy of 86.7 %. The average time assumption for patient selection was 11.9 ± 3.6 min.

Conclusions

The proposed patient selection strategy can accurately identify patients benefiting from DIBH and provides a more efficient workflow for DIBH.
基于个性化数据驱动的计算机断层扫描生成的乳腺放射治疗中深度吸气屏气的预先患者选择策略
背景目前还没有广泛使用的预先选择方法来确定患者是否适合在左侧乳房放射治疗中进行深度吸气屏气(DIBH)。目的建立一种预先选择患者的策略,以提高DIBH的决策效率,避免患者额外的CT暴露。方法共纳入174例同时进行自由呼吸(FB)和DIBH扫描的患者。训练了DIBH-CT合成的通用主成分分析模型,该模型由训练集中从配对的FB-CT和DIBH-CT中提取的主成分特征向量组成。优化矢量系数,使合成CT与测试集中每个患者屏气侦察图像的差异最小化,实现个性化的DIBH-CT合成。在综合DIBH-CT计划中建立了基于心脏剂量的预先患者选择策略。根据合成的和扫描的DIBH-CT的几何和剂量一致性来分析合成的DIBH-CT的性能。评估患者选择策略的准确性。分析了患者选择工作流程的时间假设。结果合成dibh - ct与扫描dibh - ct相比,心脏和肺部的平均Dice相似系数分别为0.84和0.91。合成DIBH-CT方案显示平均心脏剂量减少1.46 Gy,与扫描DIBH-CT方案的1.51 Gy无显著差异(p = 0.878)。患者选择策略获得了正确的获益结果,准确率为86.7%。患者选择的平均时间为11.9±3.6 min。结论所提出的患者选择策略可以准确识别从DIBH获益的患者,并为DIBH提供了更高效的工作流程。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.80
自引率
14.70%
发文量
493
审稿时长
78 days
期刊介绍: Physica Medica, European Journal of Medical Physics, publishing with Elsevier from 2007, provides an international forum for research and reviews on the following main topics: Medical Imaging Radiation Therapy Radiation Protection Measuring Systems and Signal Processing Education and training in Medical Physics Professional issues in Medical Physics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信