Predicting Severe Knee Arthritis Based on Two Inertial Measurement Unit Sensors as a Dynamic Coordinate System Using Classical Machine Learning.

IF 1.3 Q4 ENGINEERING, BIOMEDICAL
Journal of Medical Signals & Sensors Pub Date : 2025-03-13 eCollection Date: 2025-01-01 DOI:10.4103/jmss.jmss_18_24
Erfan Azizi, Mohammadsadegh Darbankhalesi, Amirhossein Zare, Zahra Sadat Rezaeian, Saeed Kermani
{"title":"Predicting Severe Knee Arthritis Based on Two Inertial Measurement Unit Sensors as a Dynamic Coordinate System Using Classical Machine Learning.","authors":"Erfan Azizi, Mohammadsadegh Darbankhalesi, Amirhossein Zare, Zahra Sadat Rezaeian, Saeed Kermani","doi":"10.4103/jmss.jmss_18_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Aging of societies in recent and upcoming years has made musculoskeletal disorders a significant challenge for healthcare system. Knee osteoarthritis (KOA) is a progressive musculoskeletal disorder that is typically diagnosed using radiographs. Considering the drawbacks of X-ray imaging, such as exposure to ionizing radiation, the need for a noninvasive, low-cost alternative method for diagnosing KOA is essential. The purpose of this study was to evaluate the ability of a wearable device to differentiate between healthy individuals and those with severe osteoarthritis (grade 4).</p><p><strong>Methods: </strong>The wearable device consisted of two inertial measurement unit (IMU) sensors, one on the lower leg and one on the thigh. One of the sensors is used as a dynamic coordinate system to improve the accuracy of the measurements. In this study, to discriminate between 1433 labeled IMU signals collected from 15 healthy individuals and 15 people with severe KOA aged over 45, new features were extracted and defined in dynamic coordinates. These features were employed in four different classifiers: (1) naive Bayes, (2) K-nearest neighbors (KNNs), (3) support vector machine, and (4) random forest. Each classifier was evaluated using the 10-fold cross-validation method (<i>K</i> = 10). The data were applied to these models, and based on their outputs, four performance metrics - accuracy, precision, sensitivity, and specificity - were calculated to assess the classification of these two groups using the mentioned software.</p><p><strong>Results: </strong>The evaluation of the selected classifiers involved calculating the four specified metrics and their average and variance values. The highest accuracy was achieved by KNN, with an accuracy of 93.71 ± 1.1 and a precision of 93 ± 1.31.</p><p><strong>Conclusion: </strong>The novel features based on the dynamic coordinate system, along with the success of the proposed KNN model, demonstrate the effectiveness of the proposed algorithm in diagnosing between signals received from healthy individuals and patients. The proposed algorithm outperforms existing methods in similar articles in sensitivity showing an improvement of 4% and at least. The main objective of this study is to investigate the feasibility of using a wearable device as an auxiliary tool in the diagnosis of arthritis. The reported results in this study are related to two groups of individuals with severe arthritis (grade 4), and there is a possibility of weaker results with the current method.</p>","PeriodicalId":37680,"journal":{"name":"Journal of Medical Signals & Sensors","volume":"15 ","pages":"8"},"PeriodicalIF":1.3000,"publicationDate":"2025-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11970831/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Signals & Sensors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jmss.jmss_18_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Aging of societies in recent and upcoming years has made musculoskeletal disorders a significant challenge for healthcare system. Knee osteoarthritis (KOA) is a progressive musculoskeletal disorder that is typically diagnosed using radiographs. Considering the drawbacks of X-ray imaging, such as exposure to ionizing radiation, the need for a noninvasive, low-cost alternative method for diagnosing KOA is essential. The purpose of this study was to evaluate the ability of a wearable device to differentiate between healthy individuals and those with severe osteoarthritis (grade 4).

Methods: The wearable device consisted of two inertial measurement unit (IMU) sensors, one on the lower leg and one on the thigh. One of the sensors is used as a dynamic coordinate system to improve the accuracy of the measurements. In this study, to discriminate between 1433 labeled IMU signals collected from 15 healthy individuals and 15 people with severe KOA aged over 45, new features were extracted and defined in dynamic coordinates. These features were employed in four different classifiers: (1) naive Bayes, (2) K-nearest neighbors (KNNs), (3) support vector machine, and (4) random forest. Each classifier was evaluated using the 10-fold cross-validation method (K = 10). The data were applied to these models, and based on their outputs, four performance metrics - accuracy, precision, sensitivity, and specificity - were calculated to assess the classification of these two groups using the mentioned software.

Results: The evaluation of the selected classifiers involved calculating the four specified metrics and their average and variance values. The highest accuracy was achieved by KNN, with an accuracy of 93.71 ± 1.1 and a precision of 93 ± 1.31.

Conclusion: The novel features based on the dynamic coordinate system, along with the success of the proposed KNN model, demonstrate the effectiveness of the proposed algorithm in diagnosing between signals received from healthy individuals and patients. The proposed algorithm outperforms existing methods in similar articles in sensitivity showing an improvement of 4% and at least. The main objective of this study is to investigate the feasibility of using a wearable device as an auxiliary tool in the diagnosis of arthritis. The reported results in this study are related to two groups of individuals with severe arthritis (grade 4), and there is a possibility of weaker results with the current method.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Medical Signals & Sensors
Journal of Medical Signals & Sensors ENGINEERING, BIOMEDICAL-
CiteScore
2.30
自引率
0.00%
发文量
53
审稿时长
33 weeks
期刊介绍: JMSS is an interdisciplinary journal that incorporates all aspects of the biomedical engineering including bioelectrics, bioinformatics, medical physics, health technology assessment, etc. Subject areas covered by the journal include: - Bioelectric: Bioinstruments Biosensors Modeling Biomedical signal processing Medical image analysis and processing Medical imaging devices Control of biological systems Neuromuscular systems Cognitive sciences Telemedicine Robotic Medical ultrasonography Bioelectromagnetics Electrophysiology Cell tracking - Bioinformatics and medical informatics: Analysis of biological data Data mining Stochastic modeling Computational genomics Artificial intelligence & fuzzy Applications Medical softwares Bioalgorithms Electronic health - Biophysics and medical physics: Computed tomography Radiation therapy Laser therapy - Education in biomedical engineering - Health technology assessment - Standard in biomedical engineering.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信