{"title":"Initial experience of transoesophageal echocardiography-guided percutaneous pulsed field ablation of atrial fibrillation.","authors":"Jun Liu, Min Tang, Guodong Niu, Chao Li, Daoliang Zhang, Yong Jiang, Yan Yao, Xiang-Bin Pan","doi":"10.1136/openhrt-2025-003172","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Pulsed-field ablation (PFA) is a new technology of catheter ablation for atrial fibrillation (AF). This research is to investigate the feasibility of a new strategy (transoesophageal echocardiography-guided pulsed field ablation, TEEP) to guide PFA for AF with no contrast and zero fluoroscopy.</p><p><strong>Methods: </strong>Patients with AF underwent TEEP under general anaesthesia with the guidance of three-dimensional (3D) transoesophageal echocardiography (TEE) throughout the procedure. After a successful transseptal puncture, the PFA catheter (CardiPulse) was delivered to the different pulmonary veins sequentially for standard PFA, and the pulmonary vein electrical isolation (PVI) was observed in real-time. After the ablation, left atrial bipolar voltage mapping under sinus rhythm was performed to verify the PVI.</p><p><strong>Results: </strong>10 patients with AF were enrolled, including 6 patients with paroxysmal AF and 4 patients with persistent AF. The mean operative time was 99±14 min, the mean time of the left atrial manoeuvre was 66±23 min, and the mean PFA ablation time was 105±8 s. First-pass PVI of all veins was achieved in all patients, thus no additional PFA applications were needed after the initial set. No contrast was needed and no X-ray was exposed. No complications were observed.</p><p><strong>Conclusions: </strong>We report the preliminary application of 3D TEE-guided PFA for AF in the world. Its immediate safety and efficacy are promising. Compared with traditional PFA procedures, TEEP has many advantages, including accuracy of the transeptal puncture, direct visualisation of contact between the catheter and myocardial tissue, no contrast and zero fluoroscopy.</p>","PeriodicalId":19505,"journal":{"name":"Open Heart","volume":"12 1","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2025-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11973749/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open Heart","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/openhrt-2025-003172","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: Pulsed-field ablation (PFA) is a new technology of catheter ablation for atrial fibrillation (AF). This research is to investigate the feasibility of a new strategy (transoesophageal echocardiography-guided pulsed field ablation, TEEP) to guide PFA for AF with no contrast and zero fluoroscopy.
Methods: Patients with AF underwent TEEP under general anaesthesia with the guidance of three-dimensional (3D) transoesophageal echocardiography (TEE) throughout the procedure. After a successful transseptal puncture, the PFA catheter (CardiPulse) was delivered to the different pulmonary veins sequentially for standard PFA, and the pulmonary vein electrical isolation (PVI) was observed in real-time. After the ablation, left atrial bipolar voltage mapping under sinus rhythm was performed to verify the PVI.
Results: 10 patients with AF were enrolled, including 6 patients with paroxysmal AF and 4 patients with persistent AF. The mean operative time was 99±14 min, the mean time of the left atrial manoeuvre was 66±23 min, and the mean PFA ablation time was 105±8 s. First-pass PVI of all veins was achieved in all patients, thus no additional PFA applications were needed after the initial set. No contrast was needed and no X-ray was exposed. No complications were observed.
Conclusions: We report the preliminary application of 3D TEE-guided PFA for AF in the world. Its immediate safety and efficacy are promising. Compared with traditional PFA procedures, TEEP has many advantages, including accuracy of the transeptal puncture, direct visualisation of contact between the catheter and myocardial tissue, no contrast and zero fluoroscopy.
期刊介绍:
Open Heart is an online-only, open access cardiology journal that aims to be “open” in many ways: open access (free access for all readers), open peer review (unblinded peer review) and open data (data sharing is encouraged). The goal is to ensure maximum transparency and maximum impact on research progress and patient care. The journal is dedicated to publishing high quality, peer reviewed medical research in all disciplines and therapeutic areas of cardiovascular medicine. Research is published across all study phases and designs, from study protocols to phase I trials to meta-analyses, including small or specialist studies. Opinionated discussions on controversial topics are welcomed. Open Heart aims to operate a fast submission and review process with continuous publication online, to ensure timely, up-to-date research is available worldwide. The journal adheres to a rigorous and transparent peer review process, and all articles go through a statistical assessment to ensure robustness of the analyses. Open Heart is an official journal of the British Cardiovascular Society.