Initial experience of transoesophageal echocardiography-guided percutaneous pulsed field ablation of atrial fibrillation.

IF 2.8 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Jun Liu, Min Tang, Guodong Niu, Chao Li, Daoliang Zhang, Yong Jiang, Yan Yao, Xiang-Bin Pan
{"title":"Initial experience of transoesophageal echocardiography-guided percutaneous pulsed field ablation of atrial fibrillation.","authors":"Jun Liu, Min Tang, Guodong Niu, Chao Li, Daoliang Zhang, Yong Jiang, Yan Yao, Xiang-Bin Pan","doi":"10.1136/openhrt-2025-003172","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Pulsed-field ablation (PFA) is a new technology of catheter ablation for atrial fibrillation (AF). This research is to investigate the feasibility of a new strategy (transoesophageal echocardiography-guided pulsed field ablation, TEEP) to guide PFA for AF with no contrast and zero fluoroscopy.</p><p><strong>Methods: </strong>Patients with AF underwent TEEP under general anaesthesia with the guidance of three-dimensional (3D) transoesophageal echocardiography (TEE) throughout the procedure. After a successful transseptal puncture, the PFA catheter (CardiPulse) was delivered to the different pulmonary veins sequentially for standard PFA, and the pulmonary vein electrical isolation (PVI) was observed in real-time. After the ablation, left atrial bipolar voltage mapping under sinus rhythm was performed to verify the PVI.</p><p><strong>Results: </strong>10 patients with AF were enrolled, including 6 patients with paroxysmal AF and 4 patients with persistent AF. The mean operative time was 99±14 min, the mean time of the left atrial manoeuvre was 66±23 min, and the mean PFA ablation time was 105±8 s. First-pass PVI of all veins was achieved in all patients, thus no additional PFA applications were needed after the initial set. No contrast was needed and no X-ray was exposed. No complications were observed.</p><p><strong>Conclusions: </strong>We report the preliminary application of 3D TEE-guided PFA for AF in the world. Its immediate safety and efficacy are promising. Compared with traditional PFA procedures, TEEP has many advantages, including accuracy of the transeptal puncture, direct visualisation of contact between the catheter and myocardial tissue, no contrast and zero fluoroscopy.</p>","PeriodicalId":19505,"journal":{"name":"Open Heart","volume":"12 1","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2025-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11973749/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open Heart","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/openhrt-2025-003172","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Pulsed-field ablation (PFA) is a new technology of catheter ablation for atrial fibrillation (AF). This research is to investigate the feasibility of a new strategy (transoesophageal echocardiography-guided pulsed field ablation, TEEP) to guide PFA for AF with no contrast and zero fluoroscopy.

Methods: Patients with AF underwent TEEP under general anaesthesia with the guidance of three-dimensional (3D) transoesophageal echocardiography (TEE) throughout the procedure. After a successful transseptal puncture, the PFA catheter (CardiPulse) was delivered to the different pulmonary veins sequentially for standard PFA, and the pulmonary vein electrical isolation (PVI) was observed in real-time. After the ablation, left atrial bipolar voltage mapping under sinus rhythm was performed to verify the PVI.

Results: 10 patients with AF were enrolled, including 6 patients with paroxysmal AF and 4 patients with persistent AF. The mean operative time was 99±14 min, the mean time of the left atrial manoeuvre was 66±23 min, and the mean PFA ablation time was 105±8 s. First-pass PVI of all veins was achieved in all patients, thus no additional PFA applications were needed after the initial set. No contrast was needed and no X-ray was exposed. No complications were observed.

Conclusions: We report the preliminary application of 3D TEE-guided PFA for AF in the world. Its immediate safety and efficacy are promising. Compared with traditional PFA procedures, TEEP has many advantages, including accuracy of the transeptal puncture, direct visualisation of contact between the catheter and myocardial tissue, no contrast and zero fluoroscopy.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Open Heart
Open Heart CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
4.60
自引率
3.70%
发文量
145
审稿时长
20 weeks
期刊介绍: Open Heart is an online-only, open access cardiology journal that aims to be “open” in many ways: open access (free access for all readers), open peer review (unblinded peer review) and open data (data sharing is encouraged). The goal is to ensure maximum transparency and maximum impact on research progress and patient care. The journal is dedicated to publishing high quality, peer reviewed medical research in all disciplines and therapeutic areas of cardiovascular medicine. Research is published across all study phases and designs, from study protocols to phase I trials to meta-analyses, including small or specialist studies. Opinionated discussions on controversial topics are welcomed. Open Heart aims to operate a fast submission and review process with continuous publication online, to ensure timely, up-to-date research is available worldwide. The journal adheres to a rigorous and transparent peer review process, and all articles go through a statistical assessment to ensure robustness of the analyses. Open Heart is an official journal of the British Cardiovascular Society.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信