Magdalena Kołodziej, Stephan Brons, Mikołaj Dubiel, George N Farah, Alexander Fenger, Ronja Hetzel, Jonas Kasper, Monika Kercz, Barbara Kołodziej, Linn Mielke, Gabriel Ostrzołek, Magdalena Rafecas, Jorge Roser, Katarzyna Rusiecka, Achim Stahl, Vitalii Urbanevych, Ming-Liang Wong, Aleksandra Wrońska
{"title":"First experimental test of a coded-mask gamma camera for proton therapy monitoring.","authors":"Magdalena Kołodziej, Stephan Brons, Mikołaj Dubiel, George N Farah, Alexander Fenger, Ronja Hetzel, Jonas Kasper, Monika Kercz, Barbara Kołodziej, Linn Mielke, Gabriel Ostrzołek, Magdalena Rafecas, Jorge Roser, Katarzyna Rusiecka, Achim Stahl, Vitalii Urbanevych, Ming-Liang Wong, Aleksandra Wrońska","doi":"10.1088/1361-6560/adc96b","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>The objective of the presented study was to evaluate the feasibility of a coded-mask (CM) gamma camera for real-time range verification in proton therapy, addressing the need for a precise and efficient method of treatment monitoring.<i>Approach.</i>A CM gamma camera prototype was tested in clinical conditions. The setup incorporated a scintillator-based detection system and a structured tungsten collimator. The experiment consisted of the irradiation of PMMA phantom with proton beams of energies ranging from 70.51 to 108.15 MeV. Experimental data were benchmarked against Monte Carlo simulations. The distal falloff position (DFP) was determined for both experimental data and simulations.<i>Main results.</i>The tested CM camera achieved a statistical precision of DFP determination of 1.7 mm for 10<sup>8</sup>protons, which is consistent with simulation predictions, despite hardware limitations such as non-functional detector pixels. Simulations indicated that a fully operational setup would further improve the performance of the detector. The system demonstrated rate capability sufficient for clinical proton beam intensities and maintained performance without significant dead time.<i>Significance.</i>This study validates the potential of the CM gamma camera for real-time proton therapy monitoring. The technology promises to enhance treatment accuracy and patient safety, offering a competitive alternative to existing approaches such as single-slit and multi-slit systems.</p>","PeriodicalId":20185,"journal":{"name":"Physics in medicine and biology","volume":" ","pages":""},"PeriodicalIF":3.3000,"publicationDate":"2025-05-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics in medicine and biology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6560/adc96b","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Objective.The objective of the presented study was to evaluate the feasibility of a coded-mask (CM) gamma camera for real-time range verification in proton therapy, addressing the need for a precise and efficient method of treatment monitoring.Approach.A CM gamma camera prototype was tested in clinical conditions. The setup incorporated a scintillator-based detection system and a structured tungsten collimator. The experiment consisted of the irradiation of PMMA phantom with proton beams of energies ranging from 70.51 to 108.15 MeV. Experimental data were benchmarked against Monte Carlo simulations. The distal falloff position (DFP) was determined for both experimental data and simulations.Main results.The tested CM camera achieved a statistical precision of DFP determination of 1.7 mm for 108protons, which is consistent with simulation predictions, despite hardware limitations such as non-functional detector pixels. Simulations indicated that a fully operational setup would further improve the performance of the detector. The system demonstrated rate capability sufficient for clinical proton beam intensities and maintained performance without significant dead time.Significance.This study validates the potential of the CM gamma camera for real-time proton therapy monitoring. The technology promises to enhance treatment accuracy and patient safety, offering a competitive alternative to existing approaches such as single-slit and multi-slit systems.
期刊介绍:
The development and application of theoretical, computational and experimental physics to medicine, physiology and biology. Topics covered are: therapy physics (including ionizing and non-ionizing radiation); biomedical imaging (e.g. x-ray, magnetic resonance, ultrasound, optical and nuclear imaging); image-guided interventions; image reconstruction and analysis (including kinetic modelling); artificial intelligence in biomedical physics and analysis; nanoparticles in imaging and therapy; radiobiology; radiation protection and patient dose monitoring; radiation dosimetry