Analytical and Real-World Clinical Characterization of S2,3PSA% Test in MRI Fusion Targeted Prostate Biopsy Population.

IF 2.6 3区 医学 Q3 ENDOCRINOLOGY & METABOLISM
Prostate Pub Date : 2025-03-30 DOI:10.1002/pros.24894
Yuki Miura, Tohru Yoneyama, Hayato Yamamoto, Hiromu Suzuki, Takuma Otsubo, Eriko Fujita, Fumiyasu Tsushima, Shintaro Goto, Teppei Okamoto, Naoki Fujita, Masahiro Ishiyama, Tadashi Yoshizawa, Shingo Kakeda, Shingo Hatakeyama, Chikara Ohyama
{"title":"Analytical and Real-World Clinical Characterization of S2,3PSA% Test in MRI Fusion Targeted Prostate Biopsy Population.","authors":"Yuki Miura, Tohru Yoneyama, Hayato Yamamoto, Hiromu Suzuki, Takuma Otsubo, Eriko Fujita, Fumiyasu Tsushima, Shintaro Goto, Teppei Okamoto, Naoki Fujita, Masahiro Ishiyama, Tadashi Yoshizawa, Shingo Kakeda, Shingo Hatakeyama, Chikara Ohyama","doi":"10.1002/pros.24894","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The α2,3-sialyl N-glycosylated free prostate-specific antigen ratio (S2,3PSA%) was approved in Japan as a prostate cancer (PCa) diagnostic test. We evaluated the analytical characterization and real-world diagnostic performance of S2,3PSA%.</p><p><strong>Methods: </strong>The precision testing, dilution linearity, measurement sensitivity, preanalytical stability, and interferences of S2,3PSA, α2,6-sialyl N-glycosylated free PSA (S2,6PSA), and S2,3PSA% were performed. The diagnostic accuracy detecting PCa of S2,3PSA% was prospectively evaluated in 253 men (Cohort 1, vs. PI-RADS) and in 145 men (Cohort 2, vs. PI-RADS, prostate health index, phi) who scheduled MRI-targeted biopsy by area under the receiver operating characteristics curve (AUC).</p><p><strong>Results: </strong>The precision of the S2,3PSA, S2,6PSA, and S2,3PSA% were all < 3.4% coefficient of variation. The dilution linearity of S2,3PSA had a correlation coefficient of 0.9949-0.9987. The detection limit of S2,3PSA and S2,6PSA was 0.044 and 0.029 ng/mL, respectively. Serum S2,3PSA and S2,6PSA concentrations were stable at 6°C for 24 h and -20°C for 90 days, while S2,3PSA% was unchanged at 6°C and -20°C for 90 days or under five freeze-thaw cycles. Serum S2,3PSA and S2,3PSA% were not affected by any interferences and drugs. In Cohort 1, AUC of S2,3PSA% (0.776, 95% CI 0.719-0.832) detecting PCa was comparable to that of PI-RADS (0.746, 0.685-0.807, p = 0.7996). In Cohort 2, AUC of S2,3PSA% detecting PCa (0.837, 0.774-0.901) was comparable to PI-RADS (0.779, 0.703-0.854, p = 0.3037), and phi (0.867, 0.809-0.926, p = 0.3000).</p><p><strong>Conclusions: </strong>Analytical characteristics of S2,3PSA% perform well and the diagnostic performance of S2,3PSA% was comparable to phi and MRI.</p>","PeriodicalId":54544,"journal":{"name":"Prostate","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2025-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Prostate","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/pros.24894","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The α2,3-sialyl N-glycosylated free prostate-specific antigen ratio (S2,3PSA%) was approved in Japan as a prostate cancer (PCa) diagnostic test. We evaluated the analytical characterization and real-world diagnostic performance of S2,3PSA%.

Methods: The precision testing, dilution linearity, measurement sensitivity, preanalytical stability, and interferences of S2,3PSA, α2,6-sialyl N-glycosylated free PSA (S2,6PSA), and S2,3PSA% were performed. The diagnostic accuracy detecting PCa of S2,3PSA% was prospectively evaluated in 253 men (Cohort 1, vs. PI-RADS) and in 145 men (Cohort 2, vs. PI-RADS, prostate health index, phi) who scheduled MRI-targeted biopsy by area under the receiver operating characteristics curve (AUC).

Results: The precision of the S2,3PSA, S2,6PSA, and S2,3PSA% were all < 3.4% coefficient of variation. The dilution linearity of S2,3PSA had a correlation coefficient of 0.9949-0.9987. The detection limit of S2,3PSA and S2,6PSA was 0.044 and 0.029 ng/mL, respectively. Serum S2,3PSA and S2,6PSA concentrations were stable at 6°C for 24 h and -20°C for 90 days, while S2,3PSA% was unchanged at 6°C and -20°C for 90 days or under five freeze-thaw cycles. Serum S2,3PSA and S2,3PSA% were not affected by any interferences and drugs. In Cohort 1, AUC of S2,3PSA% (0.776, 95% CI 0.719-0.832) detecting PCa was comparable to that of PI-RADS (0.746, 0.685-0.807, p = 0.7996). In Cohort 2, AUC of S2,3PSA% detecting PCa (0.837, 0.774-0.901) was comparable to PI-RADS (0.779, 0.703-0.854, p = 0.3037), and phi (0.867, 0.809-0.926, p = 0.3000).

Conclusions: Analytical characteristics of S2,3PSA% perform well and the diagnostic performance of S2,3PSA% was comparable to phi and MRI.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Prostate
Prostate 医学-泌尿学与肾脏学
CiteScore
5.10
自引率
3.60%
发文量
180
审稿时长
1.5 months
期刊介绍: The Prostate is a peer-reviewed journal dedicated to original studies of this organ and the male accessory glands. It serves as an international medium for these studies, presenting comprehensive coverage of clinical, anatomic, embryologic, physiologic, endocrinologic, and biochemical studies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信